SKC Inc. The World Leader in Sampling Technologies
English
Espanol
Deutsch
Francais
Portugues
systransoft.com
  Headlines:
          Anasorb CMS Status
 
Deal of the Month.  Special pricing Click Here

SKC Guide to HSE Air Sampling Methods

Chemical Hazards that begin with N

Chemical Hazard
CAS No.
HSE Method
SKC Equipment
Analytical Method
  Nickel (insoluble compounds) (except nickel tetracarbonyl) (as Ni)
 7440-02-0
91 IOM Particulate Sampler  225-70A  
Filter  225-19  
 AAS
  Nickel (insoluble compounds) (except nickel tetracarbonyl) (as Ni)
 7440-02-0
42/2 IOM Particulate Sampler  225-70A  
Filter  225-19  
 AA
  Nickel (soluble compounds only) (except nickel tetracarbonyl) (as Ni)
 7440-02-0
91 IOM Particulate Sampler  225-70A  
Filter  225-19  
 AAS
  Nickel (soluble compounds only) (except nickel tetracarbonyl) (as Ni)
 7440-02-0
42/2 IOM Particulate Sampler  225-70A  
Filter  225-19  
 AA
  Nicotine
 54-11-5
96 Sorbent Tube  226-30-04  
 GC-NPD
  Nitric acid
 7697-37-2
see NIOSH 7903 Sorbent Tube  226-10-03  
 IC
  Nitrobenzene
 98-95-3
96 Sorbent Tube  226-10  
 GC-FID
  Nitrobenzene
 98-95-3
72 Sorbent Tube  226-357  
 GC-ECD
  Nitrogen oxides
 
refer to NIOSH/OSHA Sorbent Tube  226-40  
 
  Nitromethane
 75-52-5
see NIOSH 2527 Sorbent Tube  226-111A  
 GC-NSD
 2- Nitropropane
 79-46-9
96 Sorbent Tube  226-110  
 GC-FID
  Nitrous oxide
 10024-97-2
80 Passive Sampler  590-300 
TD P226530 
 

Chemical Hazards by First Letter

A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z
Chemical Hazard Search:  
  Enter chemical name in box above

Method Number Search:
  Enter method number in box above

Catalog Number Search:
  Enter the exact SKC Catalog number in box above

CAS Number Search:  
  Enter CAS no. in box above

 


This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.

  About SKC Terms of Use Privacy Policy Contact Us Site Map Ordering Information
This site was last modified September 8, 2010
SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2000
© Copyright 1995-2010 SKC Inc