SKC Inc. The World Leader in Sampling Technologies
English
Espanol
Deutsch
Francais
Portugues
systransoft.com
  Headlines:
          Anasorb CMS Status
 
Deal of the Month.  Special pricing Click Here

SKC Guide to HSE Air Sampling Methods

Chemical Hazards that begin with O

Chemical Hazard
CAS No.
HSE Method
SKC Equipment
Analytical Method
  Oil mist
 8012-95-1
Under review 84 IOM Particulate Sampler  225-70A  
Filter  225-19  
 GR
  Orthochloroaniline (OCA)
 101-14-4
75 IOM Particulate Sampler  225-70A  
Filter  225-58F  
Sorbent Tube  226-35  
 HPLC
  Orthophosphoric acid
 7664-38-2
CD156 & TR30 refers (see NIOSH 7903) Sorbent Tube  226-10-03  
 IC
  Orthotoluidine
 95-53-4
75 IOM Particulate Sampler  225-70A  
Filter  225-58F  
Sorbent Tube  226-35  
 HPLC
  Osmium tetraoxide (as Os)
 20816-12-0
see OSHA CSI IOM Particulate Sampler  225-70A  
Filter  225-19  
Impinger  225-36-2  
Impinger Trap  225-22  
 ICP
  Oxalic acid
 144-62-7
see OSHA PV2115 Preloaded Filter Cassette  225-3-01  
Filter  225-19  
Filter Cassette and Cyclone Holder  225-1 
 IC
 2,2'- Oxydiethanol
 111-46-6
70 Sorbent Tube  226-57  
 GC-FID
  Ozone
 10028-15-6
EH38, EH64, & D83 refers (see OSHA ID 214) Coated Filter in Preloaded Cassette  225-9014  
Filter Cassette and Cyclone Holder  225-1  
 IC

Chemical Hazards by First Letter

A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z
Chemical Hazard Search:  
  Enter chemical name in box above

Method Number Search:
  Enter method number in box above

Catalog Number Search:
  Enter the exact SKC Catalog number in box above

CAS Number Search:  
  Enter CAS no. in box above

 


This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.

  About SKC Terms of Use Privacy Policy Contact Us Site Map Ordering Information
This site was last modified September 8, 2010
SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2000
© Copyright 1995-2010 SKC Inc