Chemical Hazards that begin with P

Chemical Hazard
CAS No.
HSE Method
SKC Equipment
Analytical Method
  Paracetamol (inhalable dust)
 103-90-2
14/3 IOM Particulate Sampler  225-70A  
Filter  225-58F  
 GR
  Paraffin wax (fume)
 8002-74-2
see OSHA PV2047 Preloaded Filter Cassette  225-706  
Filter Cassette and Cyclone Holder  225-1  
 GC-FID
  Paraquat dichloride (ISO) (respirable dust)
 1910-42-5
14/3 Cyclone  225-69  
Filter  225-58F  
 GR
  PCB (see polychlorinated bipheny)
 53469-21-9
     
  Pentacarbonyliron (as Fe)
 13463-40-6
see OSHA CSI Impinger  225-36-2  
Impinger  225-36-5  
Impinger Trap  225-22  
 CLR
  Pentaerythritol (inhalable dust)
 115-77-5
14/3 IOM Particulate Sampler  225-70A  
Filter  225-58F  
 GR
  Pentaerythritol (respirable dust)
 115-77-5
14/3 Cyclone  225-69  
Filter  225-58F  
 GR
  Pentan-2-one
 107-87-9
96 Sorbent Tube  226-01  
 GC-FID
  Pentan-2-one
 107-87-9
88 Passive Sampler  575-002  
 GC-FID
  Pentan-3-one
  96-22-0
88 Passive Sampler  575-001  
 GC-FID
  Pentyl acetates (all isomers)
 
EH64 refers Sorbent Tube  226-01  
 GC-FID
  Peroxodisulphate salts
 
79 IOM Particulate Sampler  225-70A  
Filter  225-19  
 IC
  Phenol
 108-95-2
96 Sorbent Tube  226-95  
 GC-FID
 p- Phenyldiamine
 106-50-3
see OSHA 87 Coated Filter in Preloaded Cassette  225-9004  
Filter Cassette and Cyclone Holder  225-1  
 HPLC-UV
 2- Phenylpropene (alpha-methyl styrene)
 98-83-9
72 Sorbent Tube  226-357  
 GC-ECD
 2- Phenylpropene (alpha-methyl styrene)
 98-83-9
88 Passive Sampler  575-001  
 GC-FID
 2- Phenylpropene (alpha-methyl styrene)
 98-83-9
96 Sorbent Tube  226-01  
 GC-FID
  Phorate (ISO)
 298-02-2
MS17 refers Sorbent Tube  226-58  
 GC-FPD
  Phosgene
 75-44-5
CD156 refers (see OSHA 61) Sorbent Tube  226-117  
 GC-NPD
  Phosphine
 7803-51-2
EH64 & D53 refers Sorbent Tube  226-165  
 UV-VAS
  Phosphorus pentachloride
 10026-13-8
TR30 refers (see OSHA CSI) Preloaded Filter Cassette  225-803  
Impinger  225-36-1  
Impinger Trap  225-22  
Screen  225-26  
 CLR
  Phosphorus trichloride
 7719-12-2
TR30 refers (see OSHA CSI) Impinger  225-36-2  
Impinger  225-36-5  
Impinger Trap  225-22  
 IC
  Phosphorus yellow
 7723-14-0
see OSHA CSI Sorbent Tube  226-35-03  
 GC-FPD
  Phosphoryl trichloride
 7719-12-2
TR30 refers (see OSHA CSI) Impinger  225-36-2  
Impinger  225-36-5  
Impinger Trap  225-22  
 IC
  Phthalates (see specific compounds)
 
     
  Phthalic anhydride
 85-44-9
62 IOM Particulate Sampler  225-70A  
Filter  225-58F  
Sorbent Tube  226-35  
 HPLC
  Picloram (ISO)
 1918-02-1
  Filter  225-8-01  
Filter Cassette  225-3LF  
Cyclone  225-01-02  
Filter Cassette and Cyclone Holder  225-1  
 GR
  Picric acid
 88-89-1
see OSHA CSI IOM Particulate Sampler  225-70A  
Filter  225-19  
 HPLC-UV
  Piperazine
 110-85-0
96    
  Piperazine
 110-85-0
72 Sorbent Tube  226-30-18  
 HPLC-UV
  Piperazine dihydrochloride
 142-64-3
72 IOM Particulate Sampler  225-70A  
Filter  225-58F  
 GC-NPD
  Piperazine dihydrochloride
 142-64-3
96    
  Piperidine
 110-89-4
70 Sorbent Tube  226-01  
 GC-FID
  Plaster of Paris (inhalable dust)
 26499-65-0
14/3 IOM Particulate Sampler  225-70A  
Filter  225-58F  
 GR
  Plaster of Paris (respirable dust)
 26499-65-0
14/3 Cyclone  225-69  
Filter  225-58F  
 GR
  Platinum (soluble compounds)
 7440-06-4
46/2 IOM Particulate Sampler  225-70A  
Filter  225-19  
 AA
  Platinum as metal
 7440-06-4
46/2 IOM Particulate Sampler  225-70A  
Filter  225-19  
 AA
  Polychlorinated biphenyls (PCB)
 53469-21-9
refer to ASTM PUF Tube  226-124  
PUF Tube  226-92  
 GC-ECD
  Polychlorinated biphenyls (PCB)
 53469-21-9
refer to OSHA Sorbent Tube  226-30-16  
 GC-ECD
  Polyvinylchloride (inhalable dust)
 
14/3 IOM Particulate Sampler  225-70A  
Filter  225-58F  
 GR
  Polyvinylchloride (respirable dust)
 
14/3 Cyclone  225-69  
Filter  225-58F  
 GR
  Portland cement (inhalable dust)
 65997-15-1
14/3 IOM Particulate Sampler  225-70A  
Filter  225-58F  
 GR
  Portland cement (respirable dust)
 65997-15-1
14/3 Cyclone  225-69  
Filter  225-58F  
 GR
  Potassium hydroxide
 1310-58-3
14/3 IOM Particulate Sampler  225-70A  
Filter  225-19  
 AA or AES
  Prop-2-yn-1-ol
 107-19-7
see OSHA 97 Sorbent Tube  226-178  
 GC-ECD
  Propan-1-ol
 71-23-8
96 Sorbent Tube  226-01  
 GC-FID
  Propan-1-ol
 71-23-8
72 Sorbent Tube  226-358  
 GC-ECD
  Propan-1-ol
 71-23-8
88 Passive Sampler  575-001  
Passive Sampler  575-002  
 GC-FID
  Propan-2-ol
 67-63-0
72 Sorbent Tube  226-358  
 GC-ECD
  Propan-2-ol
 67-63-0
88 Passive Sampler  575-001  
Passive Sampler  575-002  
 GC-FID
  Propan-2-ol
 67-63-0
96 Sorbent Tube  226-01  
 GC-FID
  Propane-1,2-diol (total particulates)
 57-55-6
14/3 IOM Particulate Sampler  225-70A  
Filter  225-58F  
 GR
  Propane-1,2-diol (total vapour & particulates)
 57-55-6
14/3 Cyclone  225-69  
Filter  225-58F  
 GR
 (2-methoxymethylethoxy) Propanol
 71-23-8
72 Sorbent Tube  226-357  
Sorbent Tube  226-358  
 GC-ECD
  Propionic acid
 79-09-4
  Passive Sampler  575-001  
 GC-FID
  Propoxur (ISO)
 114-26-1
see NIOSH 5601 Sorbent Tube  226-58  
 HPLC-UV
  Propranolol
 525-66-6
EH64 & EH65 refers    
 n- Propyl acetate
 109-60-4
72 Sorbent Tube  226-357  
 GC-ECD
 n- Propyl acetate
 109-60-4
88 Passive Sampler  575-001  
 GC-FID
 n- Propyl acetate
 109-60-4
96 Sorbent Tube  226-01  
 GC-FID
  Propylene oxide
 75-56-9
88 Passive Sampler  575-001  
 GC-FID
  Propylene oxide
 75-56-9
96 Sorbent Tube  226-01  
 GC-FID
  Propylene oxide
 75-56-9
80 Passive Sampler  575-001  
 GC-FID
  Propylene oxide
 75-56-9
72 Sorbent Tube  226-357  
 GC-ECD
  Pulverized fuel ash (respirable)
 
14/3 IOM Particulate Sampler  225-70A  
FOAM 225-772 
 GR
  Pulverized fuel ash (respirable)
 
14/3 Cyclone  225-69  
Filter  225-58F  
 GR
  Pulverized fuel ash (total Inhalable)
 
14/3 IOM Particulate Sampler  225-70A  
Filter  225-58F  
 GR
  Pyrethrins (ISO)
 
see ASTM D 4861 PUF Tube  226-92  
 GC-ECD
  Pyridine
 110-86-1
72 Sorbent Tube  226-357  
 GC-ECD
  Pyridine
 110-86-1
88 Passive Sampler  575-001  
 GC-FID
  Pyridine
 110-86-1
96 Sorbent Tube  226-01  
 GC-FID
 2- Pyridylamine
 504-29-0
see OSHA CSI Sorbent Tube  226-35-02  
 GC-FID
  Pyrocatechol
 120-80-9
see OSHA PV2014 Sorbent Tube  226-95  
 HPLC-UV

Chemical Hazards by First Letter

A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z
Chemical Hazard Search:  
  Enter chemical name in box above

Method Number Search:
  Enter method number in box above

Catalog Number Search:
  Enter the exact SKC Catalog number in box above

CAS Number Search:  
  Enter CAS no. in box above

 


This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures.

  About SKC Terms of Use Privacy Policy Contact Us Site Map Ordering Information
This site was last modified September 7, 2010
SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2000
© Copyright 1995-2010 SKC Inc