GS Series Respirable Dust Cyclones

Overcomes Bias of The Dorr-Oliver Cyclone Cyclone

GS-3 Cyclone Cat. No. 225-100
GS-3 Cyclone
Meets ACGIH/ISO/CEN respirable criteria
  • 4.0-µm 50% cut-point at a 2.75 L/min flow rate*
  • 3.5-µm 50% cut-point at a 3.7 L/min flow rate for alternate applications

Tangential inlet design decreases particle losses due to impaction

Multiple-inlet design overcomes problems reported with the Dorr-Oliver Cyclone

  • Eliminates ambient wind speed and orientation effects
  • Eliminates adverse electrostatic effects
Conductive plastic is safe for underground mine use

Sample Time: Varies

Sample Rate: 2.75 L/min for 4.0-µm 50% cut-point*
3.7 L/min for 3.5-µm 50% cut-point

Sample Pump: Universal or AirChek

Sample Media: 25 or 37-mm filters in 3-pc. cassettes

Tubing: 1/4-inch ID
* Calibrated at U. K. Health and Safety Laboratory. See the collection efficiency curve below.
Determined using experimental data obtained at flows from 2.0 to 4.0 L/min


GS-3 Multiple-inlet Cyclone Operating Instructions (PDF)

GS Cyclones Spec. Sheet (PDF)

 

The Multiple-inlet GS-3 Cyclone
The GS-3 Cyclone is a 10-mm lightweight conductive plastic unit used with a standard three-piece cassette with filter for the collection of respirable dust particles. The GS-3 Cyclone’s removable cassette adapter fits securely into the middle ring of the filter cassette during sampling. Designed to meet the ACGIH/ISO/CEN respirable convention, the GS-3 Cyclone has a 50% cut-point of 4 µm (bias within ISO/NIOSH requirements) at 2.75 L/min* or 3.5 µm at 3.7 L/min for alternate applications.

*
Calibrated at U. K. Health and Safety Laboratory.
Determined using experimental data obtained at flows from 2.0 to 4.0 L/min

Graph: Average Sampling Efficiency GS-3 Cyclone at 2.75 L/min

Designed to meet the ACGIH/ISO/CEN respirable curve,
the GS-3 Cyclone has a 50% cut-point of 4.0 µm
(bias within ISO/NIOSH requirements) at 2.75 L/min.
(click to enlarge)

GS-3 Cyclone Superior Performance
With low mean bias and higher flow rate requirements, the GS-3 Cyclone provides better sampling accuracy when compared to the performance of other cyclones used for respirable dust collection. Furthermore, the multiple-inlet GS-3 Cyclone overcomes sampling problems reported with the Dorr-Oliver Cyclone.


GS-3 Cyclone's Unique Design
Exploded View of GS-3 Cyclone with Cassette and Filter Top

  • Conductive plastic construction
    • Eliminates static collection problems with charged particles
    • Safe for underground mine use

     

  • Tangential inlets lessen sampling errors that can occur when particles impact on the wall of the cyclone opposite the inlet.
  •  

  • Multiple inlets eliminate sensitivity to wind velocity and user orientation to the contaminant source.
Exploded View of GS-3 Cyclone with Cassette and Filter


The GS-1 Single-inlet Cyclone

The GS-1 Single-inlet Cyclone 225-105
GS-1 Cyclone

  • Conductive plastic construction
    • Overcomes electrostatic effects experienced with the non-conductive Dorr-Oliver Cyclone
    • Conductive material is safe for underground mine use

  • Designed for use with the SKC DPM Cassette
    • Screens out large particles to prevent filter overload

  • Meets ACGIH/ISO/CEN respirable convention
    • 4.0-µm 50% cut-point at 2.0 L/min*
    • 3.5-µm 50% cut-point at 3.0 L/min to meet U.S. regulatory requirements
Sample Time: Varies

Sample Rate: 2.0 L/min for 4.0-µm cut-point*
3.0 L/min for 3.5-µm cut-point
1.7 or 2.0 L/min for < 1.0-µm cut-point (DPM)

Sample Pump: Universal XR or AirChek Series
Sample Media: 37-mm 3-piece cassettes, 25-mm cassettes with adapter accessory, or SKC DPM Cassette

* See reference list.
Determined using experimental data obtained at flows from 2.0 to 4.0 L/min


For more information, contact SKC Technical Support.

GS-1 Single-inlet Cyclone Operating Instructions (PDF)

GS Cyclones Spec. Sheet (PDF)  


GS-1 Cyclone
The lightweight 10-mm single-inlet GS-1 conductive plastic cyclone provides performance equivalent to the Dorr-Oliver Cyclone, with the advantage of conductive plastic construction. Conductive plastic eliminates the electrostatic effects experienced with the non-conductive nylon Dorr-Oliver Cyclone and is safe for use in underground mines. The GS-1 Cyclone is designed for use with the SKC DPM Cassette and for respirable dust sampling.

 

GS-1 Cyclone Versatility
The GS-1 Cyclone may be operated at different flow rates for sharp particle size selection that meets your application.
Flow Rate
(L/min)
Cut-point
(µm)
 Application
2.0 4.0 ACGIH/ISO/CEN respirable convention
3.0 3.5 Alternate applications
1.7 or 2.0 < 1.0 Sampling with DPM Cassette
Trakumas, S., et. al., “Performance Assessment of Personal Respirable Cyclone Samplers,” AIHce Presentation 191, 2003
Determined using experimental data obtained at flows from 2.0 to 4.0 L/min

 

Graph: GS1 Cyclone Efficiency Curve
The GS-1 Cyclone is designed to meet the ACGIH/ISO/CEN respirable convention with a 50% cut-point of 4.0 µm at 2.0 L/min. The GS-1 Cyclone can also provide a 3.5-µm 50% cut-point when operated at 3.0 L/min for alternate applications.
(Click to enlarge)

 

Using the GS-1 Cyclone with the SKC DPM Cassette
The SKC DPM Cassette is designed for sampling in atmospheres where it is necessary to separate diesel particulate matter (DPM) from other respirable dust (such as coal dust). The precision-jeweled impactor and impaction substrate, loaded into a single-use cassette, screens out respirable particles > 1.0 µm. Particles less than 1.0 µm are collected on heat-treated low-carbon quartz filters. The GS-1 Cyclone is used with the DPM Cassette to prevent larger particles (> 4 µm) from clogging the impactor as indicated in NIOSH Method 5040.

Multi-purpose Calibration Jar
The SKC Multi-purpose Calibration Jar provides convenient calibration when using a GS Cyclone, PUF tube, or OVS tube. Instead of packing four or five different calibration adapters for the field, pack only one Multi-purpose Calibration Jar. The rugged 32-ounce polypropylene jar contains a quick screw cap and barbed fitting for easy use.

Multi-purpose Calibration Jar
Cat. No.....................225-111
Multi-purpose Calibration Chamber 225-111

TechTips Logo

Red triangle

The SKC lightweight Filter Cassette/Cyclone Holder (225-1) enables a GS-3 Cyclone with three-piece cassette (inlet section removed) and filter to be attached to a worker’s collar, close to the breathing zone, for true respirable dust sampling.

The SKC Filter Cassette/Cyclone Holder is required when sampling with the GS-1 Cyclone with DPM Cassette.

Figure at right shows GS-3 Cyclone sampling train with SKC filter cassette holder and AirChek 2000 sampler.

GS-3 Cyclone  225-100 sampling train with SKC filter cassette holder and AirChek 2000 sampler 210-2000
Red triangle The SKC Multi-purpose Calibration Jar (225-111) provides easy calibration when using a GS Cyclone.

 

Ordering Information          

Description Size
Cat. No.
GS-3 Multi-inlet Cyclone with bowl adapter, cassette adapter, and grit pot 37 mm
25 mm
GS-1 Single-inlet Cyclone includes bowl adapter, 37-mm cassette adapter, and grit pot  
Accessories
Replacement Cassette Adapter, for GS-3 and GS-1 Cyclones 37 mm
25 mm
Three-piece Filter Cassette Blanks 37 mm
25 mm
Filter Cassette/Cyclone Holder includes 3 feet of 1/4-inch ID Tygon tubing and a 25-mm adapter ring, for attaching a DPM or standard filter cassette to a worker's clothing in the breathing zone. May be used with or without a cyclone, required when using the GS-1 Cyclone with the DPM Cassette
Standard-size Multi-purpose Calibration Jar
Replacement Grit Pot, pk/25

GS-3 Multiple-inlet Cyclone Operating Instructions (PDF)

GS-1 Single-inlet Cyclone Operating Instructions (PDF)

GS Cyclones Spec. Sheet (PDF)

 

References
Kar, K. and Gautam, M., "Orientation Bias of the Isolated 10 mm Nylon Cyclone at Low Stream Velocity," AIHA Journal, Vol. 56 (1995), pp. 1090-1098

Gautam, M. and Sreenath, A., "Performance of a Respirable Multi-inlet Cyclone," Journal of Aerosol Science (U.K.), Vol. 28, No. 7 (1997), pp. 1265-1281

Trakumas, S., et. al., Performance Assessment of Personal Respirable Cyclone Samplers, AIHce Presentation 191, 2003

Contact SKC Technical Support for reprints.