| Compound | ULTRA III (µg/m3) | Canister (µg/m3) |
| Benzene | 0.77 | 0.69 |
4.2 | 4.51 | |
1.98 | 1.98 | |
1.9 | 1.6 | |
6.3 | 6.8 |
| Compound | ULTRA III (µg/m3) | Canister (µg/m3) |
| Perchloroethylene |
32.9
|
29.8
|
1.1
|
1.62
|
|
2.3
|
2.2
|
|
2.85
|
2.6
|
|
2.71
|
3.4
|
| Compound | ULTRA III (µg/m3) | Canister (µg/m3) |
| o-Xylene |
1.17
|
0.91
|
13.3
|
12.0
|
|
7.55
|
7.9
|
|
0.43
|
0.39
|
|
1.3
|
1.0
|
| ULTRA III Passive Samplers prefilled with sorbent (pk/5) | Cat. No. |
| Anasorb GCB1, 370 mg in each compartment Comparable to Carbopack B Limited shelf-life | |
| Carbograph 5, 450 mg in each compartment Limited shelf-life |
|
| Chromosorb 106, 285 mg in each compartment Limited shelf-life Go to www.osha.gov and search on ULTRA for additional information on sampling rates for Chromosorb 106. | |
| Tenax TA, 265 mg in each compartment Limited shelf-life | |
| Charcoal, 500 mg in each compartment Limited shelf-life |
| Sampling Accessories | Cat. No. |
|
| Secondary Diffusion Barrier, 12 holes, lowers sampling rate for extended sampling time |
||
| Stand for Indoor Sampling | ||
| Analysis Accessory | Cat. No. |
|
| Thermal Desorption Tube, Perkin Elmer, 0.25 x 3.5 inches, includes screens and end caps | ||
List of Laboratories
for Analyzing ULTRA Passive Samplers
ULTRA III PDF downloads
Ultra III Product Data Bulletin
Analysis Instructions — ULTRA
III 690-105
Operating Instructions — ULTRA
III 690-105
Analysis Instructions — ULTRA
III 690-101, -102, -103, and -104
Operating Instructions — ULTRA
III 690-101, -102, -103, and -104
Operating Instructions — Secondary
Diffusion Barrier for ULTRA III - 690-300
Measuring
Sub-ppb Levels of VOCs in Indoor Air: Performance Comparison of
Diffusive Badges and Canisters
ULTRA Indoor/Outdoor Sampling Rates for Environmental Sampling
TO-17 Determination of Volatile Organic Compounds in Ambient or Indoor Air
Vapor Intrusion Sampling Options: Performance Data for Canisters, Badges, and Sorbent Tubes for VOCs
Monitoring Indoor Air and Workplace VOCs with Diffusive Samplers
Long-term Indoor/Ambient Air Validation Report
PowerPoint Shows
AIHce 2011 Presentation: Field Evaluation of Diffusive
Samplers for Indoor Air VOC Measurements
Download PPS file
| About SKC | Terms of Use | Privacy Policy | Contact Us | Site Map | Ordering Information |