|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Leland Legacy Sample Pump5 to 15 L/min
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| * | Leland Legacy is not recommended for high back pressure applications such as asbestos clearance sampling. |
Typical Run Time†
24+ hours:
| † | Results obtained using a new pump and new fully charged battery. Pump performance may vary. |
| ‡ | Back pressure on PTFE filters can vary within the same lot. Maximum operating temperature is 464 F (240 C) based on support ring. |
Low Levels
Longer runs at higher flows provide more sample for the enhanced
sensitivity required for measuring low concentrations, particularly
in indoor air environments.
Low Noise
With the noise-reducing case accessory, the Leland Legacy can
operate at 10 L/min and 12 inches water back pressure with
a noise level
of only 52 dBA.**
** Measured
3 feet (1 meter) from pump operating at 10
L/min without media
Advanced flow control
The patented (U.S. Patent No. 5,892,160) internal flow sensor measures
flow directly and acts as a secondary standard to constantly maintain
the set flow. Set flow is achieved immediately at start-up
and flow calibration is automatically maintained
by built-in sensors that compensate for differences in temperature
and atmospheric pressure during sampling.


Accurate automatic calibration
The patented (U.S. Patent
No's. 6,227,031 and
6,363,769) built-in CalChek feature
provides hands-free calibration between a Defender primary standard calibrator
and an SKC Leland Legacy pump for fast and easy calibration of the pumps
internal flow sensor. The Defender calibrator is
sold separately
or in convenient Leland Legacy CalChek kits.
Leland Legacy Sampler Applications
Use in non-explosive locations only.
The Leland Legacy Advantage
Collects more sample
High flows and long run times greatly increase the amount of
particulate matter collected when sampling low levels.
This
enhances the usefulness of the data for environmental health and epidemiology
studies.
Designed for indoor
environments
Noise, size, and weight are minimized relative to the high flow
range.
Downloadable history
Critical sampling parameters are retained in
memory during the sampling period and can be downloaded for record keeping.
Click here for the SKC Update to EPA IP-10A (PDF)
* Developed by Dr. Constantinos Sioutas of
the University of Southern California in partnership with NUATRC.
Leland Legacy
and Sioutas Impactor Receive ETV Verification
U.S. EPA Environmental Technology Verification (EPA-ETV)
is a program that furthers environmental protection by accelerating acceptance
and use of improved,
cost-effective technologies through performance verification. EPA-ETV
tested the performance of the SKC Leland Legacy Sample Pump with the Sioutas
Impactor. For a verification report,
visit the AMS Center at http://www.epa.gov/etv/vt-ams.html.
The SKC Leland Legacy and NUATRC
The Leland Legacy was developed in partnership
with the Mickey Leland National Urban Air Toxics Research Center (NUATRC) to
further advance personal exposure
measurement.
Established by Congress in the Clean Air Act Amendments of 1990 (CAAA), the non-profit
Leland Center is responsible for investigating public health risks posed by air
toxics to urban populations. The Leland Center is a private/public research partnership
that brings together corporate, academic, and government scientists to develop
a sound peer-reviewed air toxics research program. This program is jointly supported
by the private sector and the U.S. EPA.
Performance Profile
Leland Legacy Sample Pump
| Flow Range | 5 to 15 L/min | ||||
| Closed loop with patented internal
flow sensor U.S. Patent No. 5,892,160 |
|||||
| Compensation Range | 15 L/min at 5 inches water back pressure 10 L/min at 12 inches water back pressure 5 L/min at 20 inches water back pressure |
||||
| Accuracy |
Flow rate: ± 5% of set-point after calibration to desired flow | ||||
| Accuracy |
Timing: 1 min/mo at 25 C | ||||
| Accuracy | Atmospheric Pressure: ± 0.3 in Hg | ||||
| Flow Fault | If the pump is unable to compensate for > 15 seconds due to excessive back pressure, a flow fault icon displays and flashes, the pump enters Hold mode, and the pump retains historical data. Auto restart is attempted every 20 seconds up to 10 times. Adjustable with DataTrac for Leland Legacy software | ||||
| Tubing | Requires 3/8-inch ID tubing | ||||
| Display | LCD, displays pump serial number, pump software revision level, flow rate, volume, temperature, atmospheric pressure, time of day, run time, and pump status, i.e., hold and run as well as Setup information | ||||
| Volume Display | Continually updated, based on corrected flow rate multiplied by sampling time | ||||
| Time Display | Time of day in hours and minutes (12 or 24-hour clock) with AM and PM indicators | ||||
| Timer Display Range | 1 to 99999 minutes (69 days). If the run time exceeds 69 days, the timer display rolls over. | ||||
| Operating Temperature Range | 32 to 113 F (0 to 45 C) Protect sample pump from weather when in use outdoors. |
||||
| Typical Run Time† |
24+ hours:
|
||||
| Noise Level | 62.5 dBA — pump without case 52 dBA — pump housed in noise-reducing case (optional accessory Cat. No. 224-89) measured 3 ft (1 m) from pump operating at 10 L/min without media |
||||
| User-adjustable Values | Sample run time, calibration, clock display, flow rate, time of day, delayed start, and temperature and atmospheric pressure display | ||||
| Recorded Values | Start date and time, stop date and time, total sample time, flow rate, sample volume, temperature, atmospheric pressure, and pump mode transitions | ||||
| Adjustable Logging Interval | Records pump history from 3 seconds (15.4 min of data) up to 8 hours (over 102 days of data) depending on setting. Option available when using DataTrac Software | ||||
| Power Supply | Battery: removable, rechargeable lithium-ion (Li-Ion) battery
pack 7.4 V x 12-Ah capacity, 88.8 Wh. (See Li-Ion Battery
Shipment below.) Charger/AC adapter: input voltage 100-240 V AC |
||||
| Battery Recharge Time (with SKC-approved charger) | 15 hrs | ||||
| Temperature: Charging | 32 to 113 F (0 to 45 C) | ||||
| Temperature: Storage | -4 to 95 F (-20 to 35 C) | ||||
| Size | 8 x 3.9 x 2.6 in (20 x 10 x 7 cm) | ||||
| Weight | 36 oz (1 kg) | ||||
| Case | Thermoplastic with soft rubber overmolding | ||||
| RFI/EMI Shielding | CE marked |
| Pump Kits and Accessories* Use in non-explosive locations only; not UL Listed for intrinsic safety. Leland Legacy Pumps contain Li-Ion batteries and may be subject to special shipping regulations. |
Cat. No. | |
| Leland Legacy Pump* with
Li-Ion battery pack and screwdriver set Use in non-explosive environments only; not UL Listed for intrinsic safety; CE marked Requires charger; see kits or chargers below |
||
| Single Pump Kit* includes
Leland Legacy pump, Li-Ion battery pack, and single charger, in a Pelican
carry case, CE marked Use in non-explosive locations only; not UL Listed for intrinsic safety |
||
Single Pump CalChek Kit* includes
Leland Legacy pump, Li-Ion battery pack,
single charger/adapter unit, Defender calibrator (Revision Level
C, CalChek ready) with charger and CalChek communication cable,
and Pelican carry case. CE marked |
100-240 V |
|
| Single Pump Starter Kit includes pump with battery, charger, Tygon tubing (3 feet, ¼-inch ID), and collar clip with cable tie | 100-240 V |
100-3002-S |
| 5-pack Pump Kit* includes
5 Leland Legacy pumps, Take Charge 5 Multi-charger,
and DataTrac Software, in a Pelican case. CE marked Use in non-explosive locations only; not UL Listed for intrinsic safety |
100-240 V |
|
| 5-pack CalChek Kit* includes
items in 5-pack Leland
Legacy pump kit, CalChek Kits, Li-Ion battery packs, DataTrac Software,
and Defender calibrator (Revision Level C, CalChek
ready) with charger, and CalChek communication cable, in a Pelican
case. CE marked Use in non-explosive locations only; not UL Listed for intrinsic safety |
100-240 V |
|
| Pump Certificate |
||
| Certificate of Compliance, optional, must be ordered when ordering pump | P1501 | |
| Software | ||
| DataTrac Software for Leland Legacy includes software
CD, DataTrac adapter, and DataTrac cable Requires Windows 98 or higher and available serial port or appropriate adapter compatible with PC and system Download DataTrac Software for Leland Legacy |
||
| Calibrators and Accessories | ||
| Defender 510 Model, 300 to 30,000 ml/min includes
lead-acid battery, multi-plug charger (100-240 V), Optimizer Software,
39-inch (1-meter)
serial cable, and leak test caps Software requires Windows® 2000, XP (sp 2 or 3), or Vista (32-bit version) and RS-232 port or USB to RS-232 adapter. |
||
| Defender 520 Model, 300 to 30,000 ml/min includes
lead-acid battery, multi-plug charger (100-240 V), Optimizer Software,
and 39-inch
(1-meter) serial cable, and leak test caps Software requires Windows® 2000, XP (sp 2 or 3), or Vista (32-bit version) and RS-232 port or USB to RS-232 adapter. |
||
| Defender 530 Model, 300 to 30,000 ml/min includes
lead-acid battery, multi-plug charger (100-240 V), Optimizer Software,
39-inch (1-meter)
serial cable, and leak test caps Software requires Windows 2000, XP (sp 2 or 3), or Vista (32-bit version), and an RS-232 port or USB to RS-232 adapter. |
||
| CalChek Communication Cable,
provides direct communication between a CalChek-compatible AirChek 2000
or Leland Legacy pump and a CalChek-capable
Defender primary standard calibrator; included in CalChek kits above Note: For use only with Defender calibrators with Revision Level C or higher |
210-502 | |
| Defender Universal Charger, 100-240 V, with U.S., Euro, and Australia plugs | ||
| Defender Universal Charger, 100-240 V, with U.S. plug | ||
| Chargers and Accessories | ||
| Single Charger, for Li-Ion battery powered pumps, includes charging unit and wall cube (100-240 V worldwide power input with interchangeable plugs included) | ||
| Take Charge 5 Multi-charger, 5-station,
for Li-Ion battery powered pumps (100-240 V) Use in non-explosive locations only; not UL Listed for intrinsic safety |
||
| Single Wall Cube/Power Supply, 100-240 V, with multiple plugs, included as part of Single Charger Cat. No. 223-241 | 223-245 | |
| Li-Ion Charging Unit, 100-240 V, included
as part of Single Charger Cat. No.223-241 Note: Must be used in conjunction with the 223-245 Wall Cube Charger/Power Supply |
P22300 | |
| Replacement Li-Ion Battery Charging Unit Cable, for charger 223-241 | P75632 | |
| Battery Charging Adapter, for charging batteries outside the pump | 223-248 | |
| Pump Carry Cases and Pouches | ||
| Noise-reducing Nylon Pump Pouch, black, with lining
to reduce pump noise from 62.5 to 52 dB,
includes waist belt and shoulder strap Measured 3 feet (1 meter) from pump operating at 10 L/min without media |
||
| Single, Pelican with foam | 224-912 | |
| 5-pack, Pelican on wheels for easy transport | 224-905 | |
| Replacement Parts and Tools | ||
| Replacement Leland Legacy Battery Pack, Li-Ion | ||
| Replacement Filter/O-ring Set includes 5 filters and 1 O-ring | ||
| Replacement Inlet Filters, pk/50 | ||
| Replacement PC Board, for Leland Legacy Sample Pump, main | P7954802 | |
| Replacement LCD | P72383 | |
| Replacement Inlet, for Leland Legacy Pump | P20198 | |
| Replacement Belt Clip, for Leland Legacy Pump | P51823 | |
| Leland Legacy Case includes front and back cases; does not include serial number label | ||
| Leland Legacy Control Board | ||
| Leland Legacy Motor | ||
| Leland Legacy Inlet Side Pulsation Dampener | ||
| Replacement Yoke/Crank Arm Insert Assembly | ||
| SKC Universal Screwdriver Kit, for use with sample pumps, includes 3 interchangeable screwdriver heads | 224-11 | |
Protect sample pump from weather when in use outdoors.
| * | Li-Ion Battery
Shipment Per 2010 IATA regulations, packaging must meet the
specifications of and contain labeling and documentation required by
IATA Packing Instructions 965, 966, and 967. See IATA
Guidance |
Leland
Legacy Product Data Bulletin (PDF)
Leland Legacy Operating Instructions (PDF)
Leland Legacy Quick Guide (PDF)
CalChek with the Defender Operating Instructions (PDF)
Chinese
Language Leland Legacy Operating Instructions (PDF)
Battery Pack for Leland Legacy Sample Pumps Operating Instructions (PDF)
Take Charge 5 Li-Ion Battery Charger 223-441 Operating Instructions (PDF)
Take Charge 5 Multi-charger 223-441 CSA Certificate of Compliance (PDF)
MSDS for Lithium-Ion Rechargeable Battery (PDF)
Technical Note: SKC Sample Pump Battery Pack Characteristics and Maintenance (PDF)
Download DataTrac for the Leland Legacy
DataTrac Operating Instructions (PDF)
Leland Legacy EMC Test Certificate (PDF)
| About SKC | Terms of Use | Privacy Policy | Contact Us | Site Map | Ordering Information |