QuickTake 30 Sample PumpTake High Flow on the Go! |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Flow Range
|
10 to 30 L/min | ||||||||||||||||||||||||||||||||||||||||
Flow Compensation Accuracy
|
± 5% of set flow | ||||||||||||||||||||||||||||||||||||||||
Compensating Flow Back
Pressure Range
|
10 L/min at 90 inches water back pressure 20 L/min at 50 inches water back pressure 30 L/min at 15 inches water back pressure |
||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||
Power
|
Rechargeable 7.4-volt, 9.6-Ah capacity, 71.04 Wh lithium-ion (Li-Ion) battery or battery with AC charger/adapter (100-240 V) | ||||||||||||||||||||||||||||||||||||||||
Battery Recharge Time
|
Approximately 5 hrs with approved charger | ||||||||||||||||||||||||||||||||||||||||
Typical Cumulative Run
Time‡
|
Spore Trap (VersaTrap): 5 hrs at 15 L/min (battery
only) Note: The AC charger/adapter can be used to extend battery run time, but it is not a battery eliminator. Therefore, it will not provide indefinite run times. |
||||||||||||||||||||||||||||||||||||||||
Temperature
|
Operating: 32 to 113 F (0 to
45 C) Storage: -4 to 95 F (-20 to 35 C) Charging: 32 to 113 F (0 to 45 C) |
||||||||||||||||||||||||||||||||||||||||
Run Time Features
|
User-selectable features, user-adjustable presets. See
Operating Instructions. Preset timed runs: 1, 2, 5, 10, or 15 min Manually set continuous run with manual shut-off: 1 to 999 min (repeats 1 to 999-min runs indefinitely until user stops pump or power supply is depleted) Intermittent sampling: User-set sample periods and sample delays. See Operating Instructions. |
||||||||||||||||||||||||||||||||||||||||
Flow Fault Features
|
If the pump is unable to compensate due to excessive
back pressure, the pump will go into flow fault mode. Flow fault
features are enabled as the default setting. Flow fault may be
disabled at the user’s option. See Operating Instructions. Flow fault: Flow fault displays immediately. Pump shuts off after 5 seconds. Fault restart: Pump attempts restart every 10 seconds up to five times. |
||||||||||||||||||||||||||||||||||||||||
Media Compatibility
|
BioStage viable cascade impactors, spore trap cassettes, microvacuum cassettes, and other samplers that require flows to 30 L/min | ||||||||||||||||||||||||||||||||||||||||
Housing
|
ABS plastic | ||||||||||||||||||||||||||||||||||||||||
Dimensions
|
9.3 x 8.4 x 3.5 in (23.6 x 21.3 x 8.9 cm) | ||||||||||||||||||||||||||||||||||||||||
Weight
|
4.8 lbs (2.2 kg) | ||||||||||||||||||||||||||||||||||||||||
| ‡ Results are obtained using a new pump and new fully charged battery. Pump performance may vary. |
The SKC QuickTake 30® constant flow diaphragm pump maintains a set flow rate throughout the sampling period, compensating for the inherent back pressure created by sampling media and for any increase in back pressure as sample collects on the media. Unlike similar pumps, the QuickTake 30:

QuickTake 30 with VersaTrap
on sampling wand

QuickTake 30 with VersaTrap
Ordering Information
| Description | Cat. No. |
|
QuickTake 30 Sample Pump*† includes battery pack and cassette and tubing adapters, requires 223-245 charger accessory below Do not operate or charge in hazardous locations. Not UL Listed for intrinsic safety. Not CE marked |
||
QuickTake 30 Sample Pump and Charger*† includes one pump with battery pack, AC charger/adapter (100-240 V), cassette and tubing adapters, and tubing Do not operate or charge in hazardous locations. Not UL Listed for intrinsic safety. Not CE marked |
||
QuickTake 30 Sample Pump, Rotameter, and Charger*† includes one pump with battery pack, AC charger/adapter (100-240 V), cassette and tubing adapters, rotameter, and tubing Do not operate or charge in hazardous locations. Not UL Listed for intrinsic safety. Not CE marked |
||
QuickTake 30 BioStage Pump Kit*† includes pump and charger as described above, Standard BioStage Impactor, mounting bracket with inlet adapter, calibration adapter, and rotameter, in a deluxe carry case Do not operate or charge in hazardous locations. Not UL Listed for intrinsic safety. Not CE marked |
||
| Pump Certificate |
||
| Certificate of Compliance, optional, must be ordered when ordering pump | ||
| Chargers | ||
| Charger/Adapter, 100-240 V | ||
| Calibrators, Rotameters, and Accessories | ||
| Defender Primary Standard Calibrator, 300 ml/min to 30 L/min, includes lead-acid battery, multi-plug charger (100-240 V), Optimizer software, and 39-inch (1-meter) serial cable | ||
| Replacement Defender Lead-acid Battery Pack | ||
| Defender Universal Charger, 100-240 V, with U.S., Euro, and Australia plugs | ||
| Defender Universal Charger, 100-240 V, with U.S. plug | ||
| Rotameter, 3 to 30 L/min | ||
| Sampling Accessories | ||
| Sampling Wand, telescopes to 34 inches (0.9 meter) for ductwork and hard-to-reach locations, includes 6 feet (1.8 meters) of tubing | ||
| Cassette Adapter, for use with QuickTake
15 and QuickTake 30 Sample Pumps This adapter is also used as the calibration adapter. |
||
| Tripod Stand, telescopes to 5 feet (1.5 meters) for
mounting sample media QuickTake 30 pump will not mount on this stand. |
||
| Mounting Bracket for BioStage Impactor includes inlet adapter | ||
| Tygon Tubing, 3/8-inch ID |
10 feet
|
|
50 feet
|
||
| Replacement Parts | ||
| Replacement Inlet Filters, pk/50 | ||
| Replacement Filter/O-ring set includes 5 filters and 1 O-ring | ||
| Stem Tubing Adapter, barbed tubing adapter for use with tubing and a standard filter cassette, pk/2 | ||
| Reducing Adapter for Tubing, 3/8 inch to 1/4 inch, pk/2 | ||
| Lithium Ion Replacement Battery Pack*, for QuickTake 30 Series pumps | ||
| Replacement Stack for QuickTake 30 Pump | ||
Note: |
The AC charger/adapter can be used to extend battery run time, but it is not a battery eliminator. Therefore, it will not provide indefinite run times. Use only the SKC-approved charger for this pump. Use of an unapproved charger may damage the battery and the pump. |
† |
For bioaerosol sampling at 15 L/min, SKC recommends using the Leland Legacy pump (5 to 15 L/min) or the QuickTake 30 pump (10 to 30 L/min) |
| * | Li-Ion Battery Shipment Per 2010 IATA regulations, packaging must meet the specifications of
and contain labeling and documentation required by IATA Packing Instructions
965, 966, and 967. See IATA Guidance |
QuickTake 30 Operating Instructions (PDF)
QuickTake 30 Spec. Sheet (PDF)
Technical Note: SKC Sample Pump Battery Pack Characteristics and Maintenance (PDF)
MSDS for Lithium-Ion Rechargeable Battery (PDF)
Chinese
Language QuickTake 30 Operating Instructions (PDF)
| About SKC | Terms of Use | Privacy Policy | Contact Us | Site Map | Ordering Information |