SKC Passive Sampling Guide for 2-CELLOSOLVE acetate (ethoxyethyl acetate)

Chemical Hazard CAS No.
2-CELLOSOLVE acetate (ethoxyethyl acetate) 111-15-9
Agency Standards
OSHA TWA (ppm)   ACGIH TLV (ppm)
100   5
Sampling Parameters
Sampling Rate (ml/min)    
12.1    
Analytical Method
GC-FID — Gas Chromatography-Flame Ionization Detector
Desorption Efficiency % Desorption Solvent
95.4 Carbon disulfide (2 ml)
SKC Equipment
575-002 Passive Sampler for Organic Vapor, Anasorb 747 sorbent  
Validation Type
Calculated
Uptake rate that is calculated from the physical properties of the analyte and geometry of the sampler. Calculated rates are not based upon direct laboratory testing of the analyte with the sampler. Calculated validations are not recommended for compliance sampling.
Footnotes
CELLOSOLVE« is a registered trademark of Union Carbide Corp.

Chemical Hazard Search:
  Enter chemical name in box above

Catalog Number Search:
  Enter the catalog number in box above

CAS Number Search:
  Enter the CAS number in box above

Chemical Hazards by First Letter

A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z

This SKC Air Sampling Guide is a reference only to assist users in finding the method, sampling equipment, and sampling media for a specific compound. This publication is intended for general information only and should not be used as a substitute for reviewing applicable government regulations, equipment operating instructions, or legal standards. Users must consult the appropriate sampling method for the compound of interest before sampling. The sampling parameters shown here are suggestions based on the ranges or volume, flow, and time specified in the methods. It is the responsibility of the analyst performing the sampling and analysis steps to adjust the parameters so that the required detection limits can be obtained. The information contained in this document should not be construed as legal advice or opinion nor as a final authority on legal or regulatory procedures. CAS Registry Number is a Registered Trademark of the American Chemical Society.

 

  About SKC Terms of Use Privacy Policy Contact Us Site Map Ordering Information
This site was last modified September 16, 2014
SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2008
© Copyright 1995-2014 SKC Inc.