For release
August 9, 2010
|
||
|
SKC
has made obsolete the following products containing Anasorb CMS sorbent and
cancelled all backorders for these items. § Solvent Extraction Sorbent Tubes for NIOSH/OSHA Methods SKC
Cat. Nos. 226-121 and 226-144 § Thermal Desorption Sorbent Tubes SKC Cat. Nos. 226-330, 226-341, 226-346, 226-347, 226-349,
226-350, 226-352 §
Bulk
Sorbent SKC Cat. No. P226121 |
The SKC Sample Media Manager
is working actively with contacts at NIOSH and OSHA to find suitable
alternatives to these products. Note the alternatives recommended by SKC for
the following methods:
OSHA Method 69 for Acetone
Alternative sampler is SKC
Passive Sampler Cat. No. 575-002 (Anasorb
747).
See validation report at www.skcinc.com/pdf/1303.pdf.
OSHA Method 80 for Methylene Chloride
Alternative sampler is SKC
Passive Sampler Cat. No. 575-001 (charcoal).
See validation report at www.skcinc.com/pdf/1323.pdf.
OSHA Method 103 for Enflurane, Halothane, and
Isoflurane
Alternative sorbent tube is
SKC Cat. No. 226-81A (Anasorb 747 [140/70 mg]) as
described in the method.
OSHA Method 113 for 1,1-Dichloro-1-fluoroethane (Freon
141b) and 1,1,2-Trichloro-1,2,2-Trifluoroethane (Freon 113)
There is no alternative
indicated in the OSHA method. Stainless steel canisters are an option. Contact
your laboratory professional for recommendations.
OSHA Method 1004 for 2-Butanone (MEK) and Hexone
(MIBK)
Alternative sampler is SKC
Passive Sampler Cat. No. 575-002 (Anasorb
747).
See validation reports at www.skcinc.com/pdf/1306.pdf (MEK) and www.skcinc.com/pdf/1304.pdf (MIBK). An active alternative is sorbent tube Cat. No. 226-83
(Anasorb 747 [400/200]) with refrigerated storage.
NIOSH Method 1025 for 1- and 2-Bromopropane
Alternative sorbent tube is
SKC Cat. No. 226-01 (Coconut Shell Charcoal [100/50 mg]).
NIOSH Method 2500 for Methyl Ethyl Ketone (MEK)
Alternative sorbent tube is
SKC Cat. No. 226-81A (Anasorb 747 [140/70 mg]). A
passive alternative is SKC Passive Sampler Cat. No. 575-002 (Anasorb 747).
See validation report at www.skcinc.com/pdf/1306.pdf.
There is no alternative
listed in the NIOSH method. Use OSHA Method 1004 for MEK and MIBK above with
SKC Passive Sampler Cat. No. 575-002 (Anasorb
747).
See validation reports at www.skcinc.com/pdf/1306.pdf (MEK) and www.skcinc.com/pdf/1304.pdf (MIBK).
There is no alternative
listed in the NIOSH method. Use OSHA Methods 1012 and 1013 with SKC Sorbent
Tube Cat. No. 226-183 (specially washed/baked silica gel
and glass fiber filter [two tubes, 600 mg each]).
NIOSH Method 2562 for 1,1,2,2-Tetrachloroethane
There is no alternative
listed in the NIOSH method. Use NIOSH Method 1019 with SKC Sorbent Tube Cat.
No. 226-81A (Anasorb 747 [140/70 mg]).