Pocket Pump (20 to 225 ml/min, SKC, Inc.)

My AccountMy FavoritesCart

  Home » Catalog » Sampling Pumps » Pumps to 5 L/min » Pocket Pump (20 to 225 ml/min)

Pocket Pump
20 to 225 ml/min

Orderable Items

The Pocket Pump 20 to 225 ml/min miniature PC-programmable personal sample pump provides up to 12-hour run times for sampling gases/vapors. The pump is ideal for use with sorbent tubes.
UL Listed for intrinsic safety


Advanced Technology in
the Smallest Programmable Low Flow Pump

Constant flows from 20 to 225 ml/min 210-1000 Low Flow Pumps The Pocket Pump ® 210 Series  IN hand
  • Accommodates typical flow rates for sorbent tubes
  • Model available with twin ports for bag sampling
Compact and lightweight
  • Only 4.5 x 2.2 x 1.4 inches (11.4 x 5.6 x 3.6cm) and 5 ounces (142 grams)
  • Easily fits a shirt pocket or clips on a belt

Advanced technology with manual and PC compatibility

Ultra-quiet operation

  • For greater worker acceptance
Save time and use fewer pumps with multiple-tube sampling
  • Sample with up to 4 tubes simultaneously; select from two pump modes:
    • Constant flow mode, requires multiple-tube low flow holder and CPC
    • Constant pressure mode, requires multiple-tube low flow holder only
PC programmable with DataTrac Software
  • Program delayed start, timed run, or multiple sampling schedules
  • Download sampling data to a PC for record keeping and data analysis
No tools required
  • Simple 3-button keypad does it all
Continuous sample volume calculations
  • All sampling parameters are continuously updated
Automatic features maintain sample integrity
  • Low battery and restricted flow shut off
  • Pump stores run time data in memory
  • Auto-restart attempted after flow fault
RFI/EMI-shielded and CE marked
  • Flow unaffected by outside interferences
  • Accurate air volumes and data validity ensured
Large easy-to-read LCD
  • Displays sampling parameters, battery status, and flow fault at the touch of a button
Smart charging
  • Built-in system automatically senses maximum charge and switches to trickle charge to prolong battery life and prevent damage
Continuous run with AC adapter for extended sampling
  • Useful for environmental monitoring or 24-hour sampling without harm to the battery pack
Constant battery status display
  • View battery status before, during, and after sampling

Security code protects data

Impact-resistant case

  • Rugged case withstands rough handling in the industrial workplace
Intrinsically safe
  • UL and cUL Listed
  • Model available that meets ATEX Directive 94/9/EC (NiCad battery model only)
  • Safe in hazardous locations
  • Versatile for all industries


 


Performance Profile
Flow Range in Constant Flow Mode
20 to 225 ml/min
Accuracy Variance Between LCD Reading and Actual Flow Rate (after calibration)
20 to 225 ml/min ± 5%
Constant Flow Compensation Range (inlet only)
20 to 225 ml/min up to 20 inches water back pressure
Flow Control Accuracy
± 5% of set-point in constant flow after calibration
Pressure Range in Constant Pressure (Multiple-tube Sampling) Mode (inlet only)
1 to 10 inches of water (1.87 to 18.7 mm Hg) at a maximum flow rate of 200 ml/min for 8 hrs (12 hrs if using NiMH battery)

10 to 20 inches water (18.7 to 37.4 mm Hg) at maximum flow rate of 100 ml/min for 8 hrs (12 hrs if using NiMH battery)
Constant Pressure (Multiple-tube Sampling) Mode Accuracy
Pressure reading ± 0.5 in of water (0.25 mm Hg)
Operating Temperature
32 to 113 F (0 to 45 C)
Storage Temperature
-4 to 113 F (-20 to 45 C)
Charging Temperature
40 to 100 F (5 to 38 C)
Operating Humidity 0 to 95% non-condensing
Tubing Requires 1/4-inch ID tubing
Run Time

With NiMH: 12 hours at 200 ml/min and 10 inches water back pressure, 12 hours at 100 ml/min up to 20 inches water back pressure

Run time is 8 hrs at either setting if using NiCad battery

Varies with flow rate and sampling media in line

Using a charger with AC power: Extend run time

Timer Display Range
1 to 9999 minutes
Timing Accuracy
± 1%
Flow Fault
If the pump is unable to compensate for longer than 15 seconds due to excessive back pressure, the pump enters FLOW FAULT mode. The pump goes into HOLD, the fault icon appears on the display, and the accumulated run time display is frozen and retained. After 5 minutes in flow fault, auto-restart is attempted every 5 minutes until flow is corrected.
Battery Pack
Rechargeable NiCad battery pack, 2.4 V x 0.6 Ah or
Rechargeable NiMH battery pack, 2.4 V x 1.0 Ah
Charge Time
(varies with battery capacity and level of discharge)

< 6 hrs with Pocket Pump charger (battery attached to pump)
Approximately 16 hrs with charger (battery detached from pump)

Battery Charge Level Indicator
Icon displayed at full, mid, and low charge
Weight
5 oz (142 gm)
Dimensions
4.5 x 2.2 x 1.4 in (11.4 x 5.6 x 3.6 cm)
Case
Impact-resistant stainless steel with ABS/polycarbonate
Intrinsically Safe
UL and cUL Listed
RFI/EMI Shielding

RFI/EMI-shielded case
CE marked
Model 210-1002TX is ATEX approved (NiCad battery model only). Contact SKC.

Protect sample pump from weather when in use outdoors.

 


 


Pocket Pump showing labeled parts 210-1000 Low Flow Pumps The Pocket Pump ® 210 Series

The Three-button Keypad Does It All
Use the three buttons under the sliding cover to operate the Pocket Pump at flows from 20 to 225 ml/min. Set the flow rate in constant flow mode for single sorbent tube applications, or set the back pressure in constant pressure mode for multiple-tube applications. The Pocket Pump accommodates flow ranges for most sorbent tube and long-duration detector tube methods. Users may also select the temperature and pressure scale. Security code protected operating mode and parameters minimizes tampering and maintains sample validity. The Pocket Pump may be placed in HOLD mode at any time without loss of data.

The Pocket Pump operates in either constant flow (single-tube sampling) or constant pressure (multiple-tube sampling) mode with flows from 20 to 225 ml/min. Operation is programmed using the three-button keypad or a PC.

A built-in security code system prevents workers from changing operating state or parameters, ensuring sample validity. Multiple keys must be pressed to place the pump in HOLD; accidentally pressing one button will not alter pump operation.

Direct Readout of Data
The large easy-to-read LCD shows direct readouts of sample data that is continuously updated and may be displayed during sampling at the touch of a button. Simply press a key to scroll through the sample data that includes flow rate, air volume, temperature of the incoming air, and sample time. The LCD constantly displays a battery status icon, and a flashing flow fault icon appears when flow is restricted or blocked.

Pump-controlled Charging
Never worry about overcharging again. Since advanced electronics are built into the pump and not the charger, the smart charging battery system knows how much charging the pump needs; it never overcharges. The batteries may be charged with the battery charger while the pump is running. The Pocket Pump may operate indefinitely with the AC charger/adapter without harm to the battery pack.

The battery charge status icon is constantly displayed. When the pump loses all charge, it enters SLEEP mode while preserving the historical data in memory. When fully charged, the NiMH battery provides 12 hours of continuous use at 200 ml/min with back pressure up to 10 inches of water. Run times vary with media used.

PC Programmable with DataTrac Software
Use DataTrac Software (optional accessory) and your personal computer to make the Pocket Pump PC programmable. DataTrac simplifies chain-of-custody reporting by allowing users to program up to 14 complete running sequences including delayed start, and timed run. Pump settings can be changed with the click of a mouse button. DataTrac’s Real-time Monitor window displays a real-time readout of the Pocket Pump’s operations including time and sample volume. Lengthy calculations are unnecessary; DataTrac does it all for you. The advanced information retrieval system is specifically designed to store data and provide chain-of-custody information. DataTrac also stores historical data in pump memory that can be retrieved up to 24 hours after shutdown.

  • Program the flow rate, start and stop date, and sample duration.
  • Schedule multiple start and stop times.
  • Create a sample setup sheet for worker, sample, and analysis information.
  • Download historical records of flow rate, sample time, air volume, temperature, and more.
  • Print or save a complete report of sample and pump history information.

 


Twin Port Pocket Pump Cat.No. 210-1002A
Twin Port Pocket Pump for Sorbent Tubes and Bags

The Twin Port Pocket Pump provides flows from 20 to 225 ml/min for sampling with sorbent tubes and other low flow applications but also features an exhaust port beside the inlet port for easy bag sampling. The Twin Port Pocket Pump provides all the same operational features as the single port Pocket Pump. The 210-1002A Twin Port Pocket Pump is not UL Listed for intrinsic safety. For an ATEX-approved model order Cat. No. 210-1003MTX.