VOC Chek 575 Series Passive Samplers for PPM-level VOCs

Orderable Items

The Passive Sampler for Organic Vapors collects organic vapors without the use of a pump. The sampler is validated for short-term and eight-hour sampling and 24-hour indoor sampling for some compounds. Use the sampler to test exposure to toluene, tetrachloroethylene, trichloroethylene, xylenes, ethylbenzene, 2-butanone (MEK), hexone (MIBK), benzene, butyl acetates, and styrene.


  • Newly designed housing for easier analysis

  • No assembly required

  • Accurate and reliable — Proven performers
  • Save time and money
    • Collect most compounds with one sampler for up to a full 8-hour workshift eliminating multiple trips to the worksite
    • One sampler + one analysis = money saved
    • Economical solvent desorption and GC analysis

  • Variety of samplers available
    • Only SKC offers a choice of sorbents to better target specific contaminants
    • Proper sorbent selection means no reverse diffusion

  • Superior collection efficiency
    • SKC sorbents have a larger surface area for higher capacities
    • Samplers contain >300 mg of sorbent much more than other brands

  • Sampling flexibility
    • Validated for 15 minute and 8-hour sampling
    • Suitable for 24-hour indoor air sampling for some compounds

  • Accurate and reliable

  • So easy to use!
    • No pump or training required

  • Meet ASTM D6246-08 and ANSI/ISEA 104-1998(r 2009) standards

  • Identified as viable alternative to active sampling in seven OSHA methods

  • Easy access to sampling rates and parameters in the SKC Passive Sampling Guide


 


575 VOc Chek Banner
575 Series Passive Samplers are now
VOC Chek 575 Series!

VOC Chek Front and Back





SKC VOC Chek 575 Passive Samplers
Miniature VOC Chek 575 samplers collect organic vapors without the use of a pump. Individual chemicals simply diffuse from the atmosphere into the sampler at a fixed rate. SKC has scientifically validated the sampling rate of the VOC Chek 575 Series passive samplers along with other critical sampling parameters to meet OSHA/ASTM/ANSI requirements. SKC VOC Chek 575 Series Passive Samplers are identified as a viable alternative to active sampling in seven OSHA methods.

 

 

Full-shift Sampling with only ONE sampler

SKC VOC Chek Passive Samplers are validated for a full 8 hours, that's TWICE the limit value! This assures the integrity of the sampler, so you only need ONE sampler to get a true 8-hour TWA!

Using a VOC Chek Passive Sampler is easy as 1, 2, 3!

1. Remove front cap.

Remove front cap.



2. Clip in worker's breathing zone.

Clip in worker's breathing zone.

Cap and record information.

Cap and record information.

VOC Chek 575 Series Passive Samplers
Validated to NIOSH Protocol 1


Validation
Passive sampling is quite different from active sampling with sorbent tubes. With this fact in mind, NIOSH established validation protocols for evaluating the performance of passive samplers. 1   Protocol validation was developed so that manufacturers could produce passive samplers that reliably assess airborne levels.

For compliance sampling, it is recommended that only passive samplers with full or bi-level validation be used. Passive samplers with lower levels of validation may be used only if verified by validated sorbent sample tube methods.



Validation Level

Full
Sampler passed stringent testing as outlined in NIOSH and ANSI protocols including desorption efficiency, relative humidity, temperature, concentration, sampling rate and capacity, reverse diffusion, and storage.

Bi-Level
The most volatile member of a related (homologous) series of chemicals has passed full validation; therefore, related less volatile series members require only partial validation to achieve the same level of sampling accuracy (see Guild et al. [DOI: 10.1080/1047322X.1992.10390161] or request a copy from SKC).

Partial
Passed NIOSH protocol for sampling rate, desorption efficiency, and storage stability.

Calculated
This calculation of a sampling or uptake rate uses the diffusion coefficient of a specific chemical (D) and the cross-sectional area (A) and length (L) of the sampler’s diffusion path (based on sampler geometry).

About OSHA Testing
After extensive testing on the sampling rate variations among diffusive samplers, OSHA has released the following methods that specify diffusive (passive) samplers including SKC Cat. No. 575-002:
  • Toluene — Method 111 (1998)
  • Tetrachloroethylene and Trichloroethylene — Method 1001 (1999)
  • Xylenes and Ethylbenzene — Method 1002 (1999)
  • 2-Butanone (MEK) and Hexone (MIBK) — Method 1004 (2000)
  • Benzene — Method 1005 (2002)
  • Butyl acetates — Method 1009 (2007)
  • Styrene — Method 1014 (2009)

OSHA continues its work on passive method development based on the premise that diffusive samplers are a viable alternative to tube/pump sampling.

 

VOC Chek 575 Passive Sampler Ordering Information
 


SKC Passive Sampler for Ethylene Oxide

  • Uses same sorbent as active OSHA Method 1010
  • Fully validated and documented performance
  • 8-hour and 15-minute sampling
  • Small, lightweight, and easy to use — no pump required
  • Ideal for hospitals, veterinary clinics, and sterile instrument manufacturers

 

References

1.
Cassinelli, M.E., Hull, R.D., Crable, J.V. and Teass, A.W., "Diffusive Sampling: An Alternative to Workplace Air Monitoring," A. Berlin, R.H. Brown and K.J. Saunders (Royal Society of Chemistry, London) (eds.), NIOSH Protocol for the Evaluation of Passive Monitors, 1987, pp 190-202.

2.
Guild, L.V., Myrmel, K.H., Myers, G. and Dietrich, D.F., "Bi-Level Passive Monitor Validation: A Reliable Way of Assuring Sampling Accuracy for a Larger Number of Related Chemical Hazards" Appl. Occup. Environ. Hyg., Vol 7, No. 5, May 1992, pp. 310-317. Reprints available from SKC! Email your mailing address to SKC Inc at skcmktg@skcinc.com.


 


 


VOC Chek 575 Passive Sampling Guide for sampling rates

VOC Chek 575 Passive Sampler Product Data Bulletin (PDF)

VOC Chek 575 Passive Samplers Operating/Analysis Instructions (PDF)

Passive Sampler Research Reports

Long-term Indoor/Ambient Air Validation Report

List of Laboratories for Analyzing VOC Chek 575 Passive Samplers

Monitor Pasivo para Vapores Orgánicos Español Folleto

575 Series Passive Samplers Specified in OSHA Diffusive Methods

OSHA specifies SKC VOC Chek 575 Series diffusive (passive) samplers as a viable alternative to active sampling in six OSHA diffusive methods. OSHA continues its work on diffusive method development.

OSHA Method 111 for Toluene

OSHA Method 1001 for Tetrachloroethylene and Trichlorethylene

OSHA Method 1002 for Xylenes and Ethylbenzene

OSHA Method 1004 for 2-Butanone (MEK) and Hexone (MIBK)

OSHA Method 1005 for Benzene

OSHA Method 1009 for Butyl Acetates

OSHA Method 1014 for Styrene


For a listing of laboratories in the U.S. and Canada that analyze Passive Samplers, see the 575 Series Passive Samplers Analytical Laboratories Reference List.

Custom Passive Samplers Available
For specific applications, SKC will manufacture samplers to meet your specific requirements. Download the Custom Passive Sampler Order Form in PDF format. Complete the form and fax it to your SKC representative, contact your SKC representative, or call the SKC Sales Department at 724-941-9701 for more information.

Custom Passive Sampler Order Form (PDF)


 


Product Search
 

Express Buy
 

Products
Rentals
Sales & Service
Resources
Contact Us
Links




Information

0 items

Connect With Us


About SKC Terms of Use Privacy Policy
© Copyright 2014 SKC Inc. ISO 9001-2008