My AccountMy FavoritesCart
  Home » Catalog » Gas & Vapor Samplers » Passive Samplers » VOC Chek 575 Series Passive Samplers for PPM-level VOCs


VOC Chek 575 Series Passive Samplers for PPM-level VOCs

Orderable ItemsThe Passive Sampler for Organic Vapors collects organic vapors without the use of a pump. The sampler is validated for short-term and eight-hour sampling and 24-hour indoor sampling for some compounds. Use the sampler to test exposure to VOCs such as toluene, tetrachloroethylene, trichloroethylene, xylenes, ethylbenzene, 2-butanone (MEK), hexone (MIBK), benzene, butyl acetates, and styrene. Models exclusive for Ethylene oxide and Methanol are also available.



 
  • Decrease sampling costs
    • More sorbent/capacity + validation to 2x exposure level
    • One sampler per 8-hour shift
    • One analysis of a single layer
    • Savings for you
    • Economical sorbent desorption and GC analysis

  • Increase convenience
    • No assembly required for sampling
    • New design for easier sorbent transfer during analysis
    • New reference guide available for laboratories
    • No pump or training required

  • Increase reliability
    • Sampling rates for over 300 compounds in the SKC Passive Sampling Guide
    • Online research reports document performance for legal and compliance issues. Visit www.skcinc.com/reports.asp
    • Specialty samplers available for ethylene oxide (EtO), styrene, and methanol
    • Validated in OSHA methods as a reliable alternative to active sampling
  • Variety of samplers available
    • Only SKC offers a choice of sorbents to better target specific contaminants
    • Proper sorbent selection means no reverse diffusion

  • Superior collection efficiency
    • SKC sorbents have a larger surface area for higher capacities
    • Samplers contain > 300 mg of sorbent much more than other brands

  • Meet ASTM D6246-08 and ANSI/ISEA 104-1998(r 2009) standards

 

 


 


 


 

575 Voc Chek Banner
575 Series Passive Samplers are now
VOC Chek 575 Series!

VOC Chek Front and Back





SKC VOC Chek 575 Passive Samplers
Miniature VOC Chek 575 samplers collect organic vapors without the use of a pump. Individual chemicals simply diffuse from the atmosphere into the sampler at a fixed rate. SKC has scientifically validated the sampling rate of the VOC Chek 575 Series passive samplers along with other critical sampling parameters to meet OSHA/ASTM/ANSI requirements. SKC VOC Chek 575 Series Passive Samplers are identified as a viable alternative to active sampling in seven OSHA methods.

 

 

Full-shift Sampling with only ONE sampler

SKC VOC Chek Passive Samplers are validated for a full 8 hours, that's TWICE the limit value! This assures the integrity of the sampler, so you only need ONE sampler to get a true 8-hour TWA!

Using a VOC Chek Passive Sampler is easy as 1, 2, 3!

1. Remove front cap.

Remove front cap.



2. Clip in worker's breathing zone.

Clip in worker's breathing zone.

Cap and record information.

Cap and record information.

VOC Chek 575 Series Passive Samplers
Validated to NIOSH Protocol 1


Validation
Passive sampling is quite different from active sampling with sorbent tubes. With this fact in mind, NIOSH established validation protocols for evaluating the performance of passive samplers. 1   Protocol validation was developed so that manufacturers could produce passive samplers that reliably assess airborne levels.

For compliance sampling, it is recommended that only passive samplers with full or bi-level validation be used. Passive samplers with lower levels of validation may be used only if verified by validated sorbent sample tube methods.



Validation Level

Full
Sampler passed stringent testing as outlined in NIOSH and ANSI protocols including desorption efficiency, relative humidity, temperature, concentration, sampling rate and capacity, reverse diffusion, and storage.

Bi-Level
The most volatile member of a related (homologous) series of chemicals has passed full validation; therefore, related less volatile series members require only partial validation to achieve the same level of sampling accuracy (see Guild et al. [DOI: 10.1080/1047322X.1992.10390161] or request a copy from SKC).

Partial
Passed NIOSH protocol for sampling rate, desorption efficiency, and storage stability.

Calculated
This calculation of a sampling or uptake rate uses the diffusion coefficient of a specific chemical (D) and the cross-sectional area (A) and length (L) of the sampler’s diffusion path (based on sampler geometry).

 

 

 

Compound Active Method/
Tube Cat. No.
Passive Method/
Sampler Cat. No.
Benzene
OSHA 1005
226-01
OSHA 1005
575-002
Butyl acetates
OSHA 1009
226-01
OSHA 1009
575-002
MEK/MIBK
OSHA 16 (MEK)
226-10
OSHA 1004
575-002
Styrene
OSHA 89
226-73
OSHA 1014
575-006
Toluene
OSHA 111
226-81A or 226-01
OSHA 111
575-002
Trichloroethylene/tetrachloroethylene
OSHA 1001
226-01
OSHA 1001
575-002
Xylenes/ethylbenzene
OSHA 1002
226-01
OSHA 1002
575-002

SKC Passive Sampler for Ethylene Oxide

  • Uses same sorbent as active OSHA Method 1010
  • Fully validated and documented performance
  • 8-hour and 15-minute sampling
  • Small, lightweight, and easy to use — no pump required
  • Ideal for hospitals, veterinary clinics, and sterile instrument manufacturers

 

SKC Passive Sampler for Methanol

  • Small, lightweight, and easy to use — no pump required
  • Contains 500 mg of Anasorb 747
  • Secondary diffusion barrier provides 1.2 ml/min sampling rate
  • 8-hour and 15-minute sampling
  • Ideal for monitoring in the production of formaldehyde and other chemicals, fuel manufacturers, wastewater denitrification, and hydraulic fracturing

 

References

1.
Cassinelli, M.E., Hull, R.D., Crable, J.V. and Teass, A.W., "Diffusive Sampling: An Alternative to Workplace Air Monitoring," A. Berlin, R.H. Brown and K.J. Saunders (Royal Society of Chemistry, London) (eds.), NIOSH Protocol for the Evaluation of Passive Monitors, 1987, pp 190-202.

2.
Guild, L.V., Myrmel, K.H., Myers, G. and Dietrich, D.F., "Bi-Level Passive Monitor Validation: A Reliable Way of Assuring Sampling Accuracy for a Larger Number of Related Chemical Hazards" Appl. Occup. Environ. Hyg., Vol 7, No. 5, May 1992, pp. 310-317. Reprints available from SKC! Email your mailing address to SKC Inc at skcmktg@skcinc.com.


 


 


VOC Chek 575 Passive Sampling Guide for sampling rates

VOC Chek 575 Passive Sampler Product Data Bulletin (PDF)

VOC Chek 575 Passive Samplers Operating/Analysis Instructions for 575-001, -002 , -005, and -006 (PDF)

VOC Chek 575 Passive Samplers Operating/Analysis Instructions for 575-007 (PDF)

Passive Sampler Research Reports

Long-term Indoor/Ambient Air Validation Report

List of Laboratories for Analyzing VOC Chek 575 Passive Samplers

Monitor Pasivo para Vapores Orgánicos Español Folleto

575 Series Passive Samplers Specified in OSHA Diffusive Methods

OSHA specifies SKC VOC Chek 575 Series diffusive (passive) samplers as a viable alternative to active sampling in OSHA diffusive methods. OSHA continues its work on diffusive method development.

OSHA Method 111 for Toluene

OSHA Method 1001 for Tetrachloroethylene and Trichlorethylene

OSHA Method 1002 for Xylenes and Ethylbenzene

OSHA Method 1004 for 2-Butanone (MEK) and Hexone (MIBK)

OSHA Method 1005 for Benzene

OSHA Method 1009 for Butyl Acetates

OSHA Method 1014 for Styrene


For a listing of laboratories in the U.S. and Canada that analyze Passive Samplers, see the 575 Series Passive Samplers Analytical Laboratories Reference List.

Custom Passive Samplers Available
For specific applications, SKC will manufacture samplers to meet your specific requirements. Download the Custom Passive Sampler Order Form in PDF format. Complete the form and fax it to your SKC representative, contact your SKC representative, or call the SKC Sales Department at 724-941-9701 for more information.

Custom Passive Sampler Order Form (PDF)


 



About SKC Terms of Use Privacy Policy
© Copyright 2016 SKC Inc. ISO 9001-2008