HAZ-SCANNER EPAS


Orderable Items The HAZ-SCANNER EPAS portable direct-reading perimeter air station can be configured for up to 14 simultaneous air measurements including standard configuration of PM10 or TSP, NO2, CO, temperature, and relative humidity. Use the EPAS for hazardous incident response, waste site remediation, and ambient air quality, perimeter, and near-roadway monitoring.



 
  • Portable direct reading

  • Configure up to 14 simultaneous air measurements including U.S. EPA criteria air pollutants
    • Standard configuration measures PM10 or TSP particulates, NO2, CO, temperature, and relative humidity
    • Add one or all optional interchangeable sensors with upgradable software and/or EPAS-specific meters (for a total of 9 sensors/meters) as listed below. Choose from additional toxic gas (including methane), hydrocarbons, VOCs, and biological/chemical agent sensors and EPAS-specific meters for solar radiance/UV or IR, barometric pressure, sound/noise, atomic radiation, ELF radiation, rain, and wind speed/direction
    • Available analog input port for alternative meter
    • Interchangeable size-selective impactors are available for PM1.0, PM2.5, or PM4.0 (close approximation of respirable)
    • Can monitor up to 2 PM sizes simultaneously

  • Real-time readings, datalogging capabilities
    • Optional wireless data transmission up to 5 miles
    • Optional Ethernet internet connection for 24/7 data reporting

  • Portable and easily deployed

  • Battery operated; AC and solar panel options

  • Network up to 8 EPAS units to one central PC or Mac

  • Easy-to-use graph and reporting software compatible with PC and Mac

  • Measures ambient conditions; weather options available

 


 


 


 


 


 

Applications

  • Ambient air quality monitoring
  • Hazardous incident response
  • Special purpose monitor (SPM) and near roadway air studies
    • Complement to regulatory compliance
  • Waste site remediation
  • Military/homeland security
  • Perimeter monitoring
  • Near-roadway monitoring


 


 


 

Performance Profile

The HAZ-SCANNER EPAS is optimized for ambient air quality applications; custom calibration for specific ranges or applications is available upon request. Build the station you need for your application.

Display LCD real time
Operation 4-key splash-proof membrane switch
Power 12-V Absorption Glass Mat (AGM) rechargeable battery, 100-240 V AC, or optional solar panel
Display Measurements Max, Min, TWA, STEL
Recording Time 1 sec to 21 weeks
Sampling Rate 1 sec, 1 min, 10 min, 1 hr, adjustable
Data Storage 454,545 data points
Flow Range 1 to 3 L/min
Digital Output RS-232 (PC), RS-423 (Mac)
Software PC or Mac
Dimensions (weatherproof case) 6 x 14 x 10 in (15.2 x 35.6 x 25.4 cm)
Weight 12 lbs (5.4 kg)
Operating Temperature 23 to 122 F (-5 to 50 C)
Storage Temperature -40 to 140 F (-40 to 60 C)
Humidity 95% non-condensing (use inlet heater)
Wireless Radio Modem 900 MHz (U.S.), 868 MHz (Euro) up to 5 miles - line of sight (optional)
Auxiliary Analog Input 0 to 2.5 VDC (1 channel for alternative meter)


 


 


 


 
Haz-SCANNER EPAS shown with optional solar panels Configure an EPAS for Up to 14 Simultaneous Measurements
The standard HAZ-SCANNER EPAS includes the monitor (calibrated for ambient air applications) with sensors/meters for PM10 or TSP, VOCs, temperature, humidity, and wind speed/direction in a NEMA 4 enclosure, acid gas scrubber, internal battery, universal 110-240 V AC battery charger, software, cables, and CD with instructions.


Configure the monitor with additional sensors/meters
— up to four optional plug and play sensors and/or up to four EPAS-specific meters (listed below). See the HAZ-SCANNER EPAS Product Data Bulletin (PDF) for specifications. Specify sensors and meters when ordering.

HAZ-SCANNER EPAS shown with optional solar panels


HAZ-SCANNER software screen

 

Configure the monitor with additional sensors/meters — up to four optional interchangeable sensors with upgradable software and/or up to four EPAS-specific meters (listed below). See the HAZ-SCANNER EPAS Product Data Bulletin (PDF) for specifications. Specify sensors and meters when ordering.

Standard sensors/meters included:
  • PM10 or TSP
  • Relative humidity
  • Temperature
  • VOCs (PID)
  • Wind speed/direction
Optional sensors/meters available:
  • Ammonia (GSS)
  • Atomic radiation
  • Barometric pressure
  • Carbon dioxide (NDIR)
  • Carbon monoxide (EC) (replacement part)
  • Chlorine (EC)
  • Dew point temperature
  • Ethylene oxide (EL)
  • Hydrocarbon (methane-specific, EC)
  • Hydrocarbons (EC)
  • Hydrogen chloride (EL)
  • Hydrogen cyanide (EC)
  • Hydrogen sulfide (EC)
  • Nitric oxide (EC)
  • Nitrogen dioxide (replacement part)
  • Oxygen
  • Ozone
  • Phosphine (EL)
  • PM1.0, 2.5, or 4.0
  • Rain
  • Solar radiance
  • Sound and noise
  • Sulfur dioxide
  • Wet bulb temperature