Teflon Filters
(Polytetrafluoroethylene Filters) (PTFE)
 |
 |
| 5.0 µm and 60 µm
pore sizes |
0.5 µm, 1.0 µm and 2.0 µm pore sizes |
- Chemically resistant
- Hydrophobic
- Low background, interference-free chemical determinations
- Low tare mass for accurate gravimetric results
- Autoclavable
- Meet OSHA, NIOSH, and EPA method specifications
SKC PTFE filters are strong and completely resistant to acids,
bases, and all solvents. Use PTFE filters when sampling in aggressive
environments. A low chemical background makes PTFE filters ideal
for sampling low concentration contaminants. Naturally hydrophobic,
PTFE filters feature a low tare mass for accurate gravimetric
determinations SKC PTFE filters are temperature-stable to 527
F (275 C). The maximum operating temperature for Teflon filters
with PMP support ring is 464 F (240 C). PTFE filters are prone
to static effects. For the most accurate sampling use a static
eliminator.
Ordering Information
| Diameter (mm) |
Pore Size
(µm) |
Support Pad Included |
Notes |
Qty. |
Cat. No. |
| 13 |
5.0 |
No |
unlaminated |
100 |
225-17-03 |
| 25 |
0.5 |
No |
with PTFE support |
100 |
225-2708 |
| 25 |
1.0 |
No |
with laminated PTFE support |
100 |
225-2714 |
| 25 |
2.0 |
No |
with laminated PTFE support |
100 |
225-2726 |
| 25 |
3.0 |
No |
with PMP support ring †‡ |
50 |
225-1711 |
| 25 |
5.0 |
No |
unlaminated |
50 |
225-1728 |
| 37 |
0.3 |
No |
PTFE, not-sterilized *
for Anthrax and SARS, available in ready-to-use preloaded
cassettes |
100 |
225-1722 |
| 37 |
0.45 |
Yes |
on polypropylene support |
100 |
225-17-04 |
| 37 |
0.5 |
No |
with PTFE support and hole
for Respicon™ Sampler |
50 |
225-1762 |
| 37 |
1.0 |
Yes |
on polypropylene support |
100 |
225-17-01 |
| 37 |
1.0 |
No |
with PTFE laminated support |
50 |
225-2705 |
| 37 |
2.0 |
Yes |
with laminated PTFE support
|
50 |
225-27-07 |
| 37 |
2.0 |
No |
with PMP support ring ‡ |
50 |
225-1709 |
| 37 |
5.0 |
Yes |
unlaminated |
50 |
225-17A |
| 37 |
10.0 |
No |
unlaminated |
100 |
225-1729 |
| 47 |
0.5 |
No |
with laminated PTFE support |
50 |
225-2753 |
| 47 |
1.0 |
No |
with laminated PTFE support |
50 |
225-2749 |
| 47 |
2.0 |
No |
with PMP support ring ‡ |
50 |
225-1747 |
| 47 |
2.0 |
No |
with laminated PTFE support |
50 |
225-2748 |
| 47 |
5.0 |
No |
unlaminated |
100 |
225-1724 |
| 47 |
60.0 |
No |
unlaminated |
100 |
225-1755 |
| † |
Recommended
for use with the Button Sampler |
| * |
Recommended for Anthrax and SARS |
| ‡ |
The maximum operating temperature for Teflon filters with PMP support
ring is 464 F (240 C) |
Filter/Cassette Solvent Compatibility Chart (HTML)
Filter/Cassette
Solvent Compatibility Chart (PDF)
Filter FAQs
MSDS — Teflon (PTFE, Polytetrafluoroethylene) Filters
Specialty PTFE Filters for the Respicon™ Sampler
| Specialty PTFE Filters |
| Diameter (mm) |
Pore Size
(µm)
|
Support Pad Included |
Notes |
Qty. |
Cat. No. |
| 37 |
0.5 |
No |
with PTFE support and hole for the Respicon™ Sampler |
50 |
225-1762 |
Preloaded PTFE Filters
|
 |
All SKC preloaded filters are in SureSeal* leak-free
cassettes
|
Ordering Information
| Diameter |
Filter and Cassette Specifications |
Qty. |
Cat. No. |
| 25 mm |
PTFE, 1.0 µm with
PTFE support and porous
plastic pad loaded in conductive 2-pc cassette |
50 |
225-1725 |
| 25 mm |
PTFE, 1.0 µm with
polypropylene support pad preloaded into 2-pc goblet-style black conductive
cassette |
50 |
225-1751 |
| 25 mm |
PTFE, 1.0 µm with
cellulose support pad preloaded into 2-pc goblet-style conductive
cassette |
50 |
225-1716 |
| 25 mm |
PTFE, 2.0 µm filters with 60
µm laminated support and polypropylene support pad preloaded into
2-pc goblet-style black conductive cassette |
50 |
225-1750 |
| 37 mm |
PTFE, 0.3 µm, unsterilized 3-pc
cassette banded, recommended for Anthrax
and SARS |
50 |
225-1723 |
| 37 mm |
Zefluor PTFE, 1.0 µm with 60 µm laminated
PTFE support, preloaded in a 3-pc, clear styrene (traditional style)
cassette, banded |
50 |
225-1715 |
| 37 mm |
Zefluor PTFE, 2.0 µm with PTFE support,
2-pc plastic cassette with spacer ring, banded |
50 |
225-1713 |
* SureSeal leak-free
cassettes require the use of a SureSeal Cassette Opener 225-13-5A
Filter/Cassette Solvent Compatibility Chart (HTML)
Filter/Cassette
Solvent Compatibility Chart (PDF)
MSDS — Teflon
(PTFE, Polytetrafluoroethylene) Filters
PTFE for Anthrax and SARS
NIOSH is currently using non-sterilized PTFE filters to sample for Severe Acute Respiratory Syndrome (SARS). These filters are also suitable for sampling Anthrax.
Diameter (mm) |
Pore Size (µm) |
Notes |
Cassette Description |
Qty.
|
Cat. No. |
| 37 |
0.3 |
not sterilized** |
filters only |
100 |
|
| 37 |
0.3 |
not sterilized** |
3-pc styrene |
50 |
|
| ** |
Sterilization is not required because analysis is very specific and does
not have interferences. |
Filter/Cassette Solvent Compatibility Chart (HTML)
Filter/Cassette
Solvent Compatibility Chart (PDF)
MSDS — Teflon
(PTFE, Polytetrafluoroethylene) Filters
A typical filter will have a rough side and a shiny side. The shiny side is easier to read under a microscope, therefore, expose the shiny side to the air for microscopic analysis. The rough side holds dust more effectively; expose the rough side for gravimetric analysis.
Custom Filters Available
For specific applications, SKC will manufacture filters to meet your specific
requirements. Download the Custom Filter Order Form in PDF format. Complete
the form and fax it to your SKC
representative, or contact your SKC
representative, or call the SKC Sales Department at 724-941-9701 for
more information.
Custom Filters Order Forms
(PDF Format)
This page was last modified June 11, 2009