BioStage
Single-stage Viable Cascade Impactor
 |
|
| |
Standard BioStage |
|
BioStage 200 |
| Jet Classification Stage |
400 holes (0.25-mm dia) |
|
200 holes (0.25-mm dia) |
| Flow Rate |
28.3 L/min |
|
14.15 L/min |
| Sample Media |
90 to 100-mm agar plates |
|
90 to 100-mm agar plates |
| Analysis |
Colony culture‡ |
|
Colony culture‡ |
- Easy to use
- Proven principle of operation
- Meet ACGIH® recommendations for bioaerosol sampling
- Meet NIOSH Method 0800 and 0801 requirements
- Performance equivalent to Andersen N-6 and Aerotech 6**
- Corrosion-resistant aluminum
- Autoclavable
- Collected organisms remain intact and viable
- Easy setup and calibration
- SureLock positive seal ensures sample integrity
BioStage
Operating Instructions (PDF)
BioStage
Spec. Sheet (PDF)
BioStage
Analytical Laboratories Reference List
Reference:
Positive-Hole Correction of Multiple-Jet Impactors for Collecting
Viable Microorganisms (PDF)
BioStage
FAQs
BioStage® single-stage bioaerosol impactors
operate on the principle of inertial impaction and meet NIOSH Method
0800 and
0801 specifications and ACGIH recommendations for sampling
indoor and outdoor air for viable microorganisms, including bacteria,
fungi, and actinomycetes. Made of precision-tooled autoclavable aluminum,
the sampler
contains a jet classification stage and base plate precision-threaded
together for a positive seal and an inlet cone. The impactor stage
contains precision-drilled
holes. A sample pump draws air through the sampler where multiple
jets of air direct airborne particles toward the surface of the agar
collection medium.
Two models of the BioStage Impactor are available to accommodate
two
different flow rates.
Only SKC offers the SureLock positive seal advantage!
The SKC Standard BioStage Cascade Impactor is constructed with
the same 400-hole jet classification stage as the Andersen N-6
Impactor. However, only the SKC BioStage features the SureLock positive
seal that:
- Prevents air leaks to ensure complete sample integrity
- Does not depend on spring clamps that wear out or fail
- Requires minimal maintenance
|
|
Single-stage impactor
with spring clamps
|
Single-stage BioStage
with SureLock Seal
|
Applications
- Indoor Air Quality (IAQ) studies
- Filter and cleanroom efficiency studies
- Pharmaceutical production
- Brewery fermentation
- Animal care laboratories
- Food processing areas
- Sewage treatment plants
- Hospital environments
- Cosmetic manufacturing
- Grain processing and transportation
- Bio-risk response
Operation
The BioStage single-stage impactors are easy to use. A barbed outlet fitting
allows fast and easy connection to a vacuum pump. The SureLock positive seal
keeps the jet classification stage and agar plate securely in place and prevents
leakage during sampling. Sampling is as simple as sealing an agar plate inside
the BioStage, connecting the impactor to a pump operating at the appropriate
flow rate, sampling for two to five minutes, removing the agar plate, and
sending it to a qualified laboratory for analysis.
About the BioStage 200
In addition to the standard BioStage, SKC offers the BioStage 200 with a 200-hole
jet classification stage. Designed to cut the sampling job in half, BioStage
200 accommodates a 90 to 100-mm agar plate and requires only a 14.15 L/min
flow rate. Use a quiet, portable, and battery-operated 15 L/min sample pump
such as the QuickTake 15 for fast, convenient sampling.
Performance Profile
Flow
Rate |
Standard BioStage: 28.3 L/min
BioStage 200: 14.15 L/min |
Material |
Inlet cone and base plate: Precision-tooled
autoclavable aluminum
O-rings: Duro 50, BUNA-N |
Jet Classification Stage |
Standard: 400 holes
BioStage 200: 200 holes |
Sample Media |
90 to 100-mm agar plates*
|
Suggested Media |
For bacteria:
Tryptic Soy Agar (TSA)
Blood Agar Plates (BAP)
For fungi:
Potato Dextrose Agar (PDA)
Malt Extract Agar (MEA)
Dichloran Glycerol 18 Agar (DG-18)
Corn Meal Agar (CMA) |
Analysis |
Colony culture‡ |
The QuickTake 30
The SKC QuickTake
30 Sample Pump is designed for easy use with the SKC BioStage
and other impaction devices that require flows to 30 L/min.
The mounting bracket accessory holds the BioStage Impactor
securely onto the QuickTake 30 sample pump for fast setup,
easy sampling, and portability. |
 |
Ordering Information
| Description |
Cat. No. |
Standard BioStage* single-stage
bioaerosol impactor |
|
| BioStage 200* single-stage
bioaerosol impactor |
|
| BioStage Pump Kit-AC includes Standard BioStage
impactor*, vacuum
pump (Gast
1532)
with rotameter, tubing, calibration adapter, tubing, tripod
stand, and carry case |
|
BioStage Pump Kit-DC includes
Standard BioStage impactor*, QuickTake
30 pump with
battery, AC charger/adapter, calibration adapter, mounting
bracket with inlet adapter, rotameter, tubing, and deluxe
carry case
|
|
| BioStage 200 Pump Kit includes
BioStage 200* impactor,
QuickTake 15 pump, AC charger/adapter (115V), rotameter, tripod
stand, tubing, calibration adapter,
and carry case |
|
| BioStage 200 Pump Kit includes
BioStage 200* Impactor
(for use with 90 to 100-mm agar plates), QuickTake 15
sampling pump with charger (100-240 V, CE marked), tripod stand,
tubing, calibration adapter, and carry case |
|
| QuickTake
30 Sample Pump,† with
battery pack, AC charger/adapter, and cassette/tubing adapter |
|
| Accessories |
Calibration Adapter for BioStage, allows tubing
to connect to BioStage inlet. Suitable for both models
|
P33100 |
| Tripod Stand, telescopes to 5 ft to hold
BioStage in breathing area (does not hold pump) |
|
| Mounting Bracket for QuickTake 30, holds
BioStage in place on pump during sampling |
|
| Replacement O-ring for Base Plate, ea |
|
| Replacement O-ring for Inlet Cone, pk/2 |
|
| * |
Requires microbiological
media supplied by analytical laboratories. For lab list see the: BioStage
Analytical Laboratories Reference List or visit the
AIHA website at www.aiha.org. |
| † |
QuickTake pumps contain Li-Ion batteries and are subject to
special shipping regulations |
| ‡ |
In situations where spore counts are high, positive
hole correction should be used. See Macher, J., "Positive-Hole
Correction of Multiple-jet Impactors for Collecting Viable Microorganisms," American
Industrial Hygiene Journal, 50 (11), 1989, pp. 561-568. |
| ** |
Samimi, B. and Shufutinsky, A., "Comparison
of the Thermo-Andersen N6, the Aerotech A6, the SKC BioStage,
and the SKC Micromedia
Viable Samplers in the Collecting Airborne Fungal Spores," AIHce,
San Diego, CA, Final Program, p. 43. |
| |
Yao, M. and Mainelis, G., "Analysis of Portable Impactor
Performance for Enumeration of Viable Bioaerosols," Journal
of Occupational and Environmental Hygiene, Vol. 4, Issue 7, July
2007, pp. 514-524. |
BioStage
Operating Instructions (PDF)
BioStage
Product Spec. Sheet (PDF)
BioStage
Analytical Laboratories Reference List
Reference:
Positive-Hole Correction of Multiple-jet Impactors for Collecting
Viable Microorganisms (PDF)
BioStage
FAQs
This page was last modified March 27, 2008
|