SKC: Shaping the Future of Air Sampling  
 
 Español
 Deutsch
 Français
 Portuguese
 

 

 

Vac-U-Chamber

Negative Pressure Eliminates Risk of Pump Contamination

Features
Vac-U-Chamber image
  • Allows direct filling of air sample bags
    • Uses negative pressure provided by most personal air sample pumps
    • Designed for SKC sample bags

  • Protects from contamination
    • Sample does not pass through the pump
    • Stainless steel and Teflon® surfaces eliminate contamination

  • Rugged heavy-duty construction
    • Will not collapse under vacuum

  • Two sizes available
    • Large for sample volumes up to 8 liters
    • Small for sample volumes up to 1 liter

Vac-U-Chamber Spec. Sheet (PDF)

The SKC Vac-U-Chamber
For Convenient, Reliable Bag Sampling

The SKC Vac-U-Chamber™ is a rigid air sample box that allows sample bags to be filled directly by using negative pressure provided by most personal air sample pumps. Since the air sample does not pass directly through the pump, both pump and sample contamination are eliminated. The Vac-U-Chamber’s rigid walls will not collapse under vacuum conditions. All surfaces in contact with the sample are constructed of stainless steel or Teflon for inertness.

Applications
  • Stack sampling
  • Ventilation studies
  • HazMat testing
  • Soil gas sampling
  • Groundwater testing
  • Ambient or indoor air sampling
  • EPA Method 30


Using the Vac-U-Chamber

The Vac-U-Chamber is equipped with three 1/4-inch OD fitting ports for inflating sample bags:
  • Sample inlet port for connecting to the sample line or gas source

  • Purge port for purging the air prior to sampling or when preparing the bag for a standard

  • Vacuum port for inflating a bag
An air sample bag is connected to the inside sample inlet port and the chamber is closed, providing an airtight seal. An air sample pump is connected to the outside vacuum outlet port. When activated, the pump evacuates air from inside the chamber. The sample bag inflates as a result of the interior pressure drop. This pneumatic technique allows the air sample to enter the bag directly without passing through the pump, protecting the pump from sample contaminants and the sample from pump contaminants.

Ordering Information        

Large Vac-U-Chamber

Description Cat. No.

Complete Vac-U-Chamber Kit includes PCXR4 sample pump, single PowerFlex charger with cable, large Vac-U Chamber, and ten 232-939 sample bags
100-240 V

224-4115
Large Vac-U-Chamber only with stainless steel fittings (supplied without pump), suitable for use with 236-004 or 232-939 bags 231-939
8-liter Tedlar Bag with single polypropylene fitting, 12.75 x 18 in, for use with large Vac-U-Chamber (Cat. No. 231-939), pk/10 232-939
8-liter FlexFilm Bag with single polypropylene fitting, 12 x 18 in, for use with large Vac-U-Chamber (Cat. No. 231-939), pk/10 236-004
Quick Disconnect with tubing for replacement in Cat. No. 231-939 P231941
Teflon tubing, 5/16-inch OD (1/4-inch ID), 10 feet 231-937
Teflon tubing, 5/16-inch OD (1/4-inch ID), 50 feet 231-924

Small Vac-U-Chamber

Description Cat. No.
Complete Vac-U-Chamber Kit includes PCXR4 sample pump, single PowerFlex charger with cable, small Vac-U-Chamber, and ten 232-01 sample bags
100-40 V
224-4124
Small Vac-U-Chamber only with polypropylene fi ttings (supplied without pump), suitable for use with 236-001 or 232-01 bags 231-940
1-liter Tedlar Bag with single polypropylene fitting, 7 x 7 in, for use with small Vac-U-Chamber (Cat. No. 231-940), pk/10 232-01
1-liter FlexFilm Bag with single polypropylene fitting, 8.25 x 7.25 in, for use with small Vac-U-Chamber (Cat. No. 231-940), pk/10 236-001

The Vac-U-Chamber is available in other sizes and fittings as a custom order. Contact your SKC representative for more information.

 

Vac-U-Chamber Spec. Sheet (PDF)

Gas Sample Bags Page

Sample Pumps Page


This page was last modified March 16, 2009
  About SKC Terms of Use Privacy Policy Contact Us Ordering Information

This site was last modified July 2, 2009

SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2000
© Copyright 1995-2009 SKC Inc