SKC: Shaping the Future of Air Sampling  

 

 

UMEX 200 Passive Sampler
For Sulfur Dioxide and Nitrogen Dioxide

  • Accurate, reliable personal sampling
    UME<sup>X</sup> 500-200 with Callouts
  • Ready to use

  • Lightweight sampler clips easily in the breathing zone

  • Economical
    • No pump or training required
    • Low-cost single-use sampler
    • Sample medium and blank/correction in one unit

  • Safe — no glass or chemical liquids in the sampler

  • Accurately measures personal workplace exposure to sulfur dioxide and/or nitrogen dioxide

  • 3-week sample storage at ambient temperature

UMEX 200 Product Data Bulletin (PDF)

UMEX 200 Performance Profile (PDF)

UMEX 200 Sulfur Dioxide Research Report (PDF)

UMEX 200 Nitrogen Dioxide Research Report (PDF)

UMEX 200 Operating Instructions (PDF)

List of Laboratories for Analyzing 500-200 Series UMEX Passive Samplers

The single-use SKC UMEX 200 Passive Sampler effectively collects sulfur dioxide (SO2) at a sampling rate of 15.1 ml/min and/or nitrogen dioxide (NO2) at 12.83 ml/min. The sample medium (tape treated with triethanolamine [TEA]) and a "blank/correction" section of tape are contained in one sampler saving time and money. The lightweight UMEX 200 clips in the breathing zone for easy personal sampling. Samplers are provided in individual aluminized pouches that can be used to transport the sampler to a laboratory. The label on the outside of each pouch contains the shelf-life date for easy inventory management.

Using the UMEX 200 Passive Sampler
Sampling with the UMEX 200 Passive Sampler for sulfur dioxide and/or nitrogen dioxide is easy and requires no pump or training. Simply remove the sampler from the pouch, record sampling information, and slide the cover to the "on" or sampling position. Clip the sampler on a worker for personal sampling up to eight hours. When sampling is complete, slide the cover to the "off" position, place the sampler back in the pouch immediately, and seal. Send the sampler to an accredited laboratory for analysis by solvent extraction ion chromatography (IC) with conductivity detection.

 

Performance Profile

Sampling Rate SO2: 15.1 ml/min with a relative standard deviation of 16.7%
NO2: 12.83 ml/min with a relative standard deviation of 13.4%
Validated Concentration Range for SO2 and/or NO2 0.4 to 8 ppm
Analysis Method for SO2 and/or NO2 Solvent extraction and ion chromatography with conductivity detection
Lower Detection Limits for SO2 and/or NO2 15 minutes: 2 ppm
8 hours: 0.1 ppm
Shelf-life 18 months from date of manufacture at ambient temperature
Storage Before use: Ambient temperature
After use: Analyze within 3 weeks. Can be stored at ambient temperature or at < 39.2 F (4 C)
Accuracy for SO2 and/or NO2
± 30%
Temperature Effects No effect on sampling rate between 20 and 25 C
Humidity Effects No effect from 20 to 80% relative humidity
Wind Effects No effect from 0.05 to 1.0 m/s
Interferences None identified
Dimensions 3.4 x 1.1 x 0.35 in (8.6 x 2.8 x 0.89 cm)
Weight 0.38 oz (10.9 gm)
Slide Cover Yellow

Potential Sources of Workplace Exposure to Sulfur Dioxide and Nitrogen Dioxide

Sulfur dioxide is used in industry as a(n):
  • Intermediate in sulfuric acid manufacture
  • Bleaching agent
  • Disinfectant
  • Fumigant
  • Solvent
  • Refrigerant
  • Food preservative
  • Reagent in the manufacture of magnesium, sodium sulfite, and other chemicals
Other sources are:
  • Copper smelting
  • Processing or burning coal or fuel oil
  • Paper manufacturing
  • Fertilizer manufacturing

Nitrogen Dioxide is used in:

  • Agricultural silos
  • Arc or gas welding, especially in confined space
  • Electroplating plants
  • Food and textile bleaching
  • Jewelry manufacturing
  • Nitric acid production
  • Nitrogen fertilizer production
  • Nitro-explosive production
  • Pickling plants

    Source: OSHA Method ID-182

Other UMEX Passive Samplers Available
The same convenient and economical UMEX design is also available for sampling formaldehyde/other aldehydes (UME 100) and amines (UMEX 400).

 

Ordering Information

Description
Cat. No.

UMEX 200 Passive Sampler for Sulfur Dioxide and/or Nitrogen Dioxide, individually packaged in aluminized pouch, pk/10
UMEX samplers are designed for single use only. Do Not reuse UMEX samplers.
Limited shelf-life. Do not store with food.

UMEX 200 Product Data Bulletin (PDF)

UMEX 200 Performance Profile (PDF)

UMEX 200 Sulfur Dioxide Research Report (PDF)

UMEX 200 Nitrogen Dioxide Research Report (PDF)

UMEX 200 Operating Instructions (PDF)

List of Laboratories for Analyzing 500-200 Series UMEX Passive Samplers


This page was last modified April 19, 2010
  About SKC Terms of Use Privacy Policy Contact Us Ordering Information

This site was last modified July 29, 2010

SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2000
© Copyright 1995-2010 SKC Inc