UMEX 200 Passive Sampler
For Sulfur Dioxide and Nitrogen Dioxide
- Accurate, reliable personal sampling

- Ready to use
- Lightweight sampler clips easily in the breathing zone
- Economical
- No pump or training required
- Low-cost single-use sampler
- Sample medium and blank/correction in one unit
- Safe — no glass or chemical liquids in the sampler
- Accurately measures personal workplace exposure to
sulfur dioxide and/or nitrogen dioxide
- 3-week sample storage at ambient temperature
UMEX 200 Product
Data Bulletin (PDF)
UMEX 200 Performance
Profile (PDF)
UMEX 200 Sulfur
Dioxide Research Report (PDF)
UMEX 200 Nitrogen
Dioxide Research Report (PDF)
UMEX 200 Operating
Instructions (PDF)
List
of Laboratories for Analyzing 500-200 Series UMEX Passive Samplers
The single-use SKC UMEX 200 Passive Sampler effectively collects
sulfur dioxide (SO2) at a sampling
rate of 15.1 ml/min and/or nitrogen dioxide (NO2) at 12.83 ml/min.
The sample medium (tape treated with triethanolamine [TEA]) and a "blank/correction" section
of tape are contained in one sampler saving time and money.
The lightweight UMEX 200 clips in the breathing zone for
easy personal sampling. Samplers are provided in individual
aluminized pouches that can be used to transport the sampler
to a laboratory. The label on the outside of each pouch contains
the shelf-life date for easy inventory management.
Using the UMEX 200 Passive
Sampler
Sampling with the UME
X 200 Passive Sampler for sulfur dioxide
and/or nitrogen dioxide is easy and requires no pump or training. Simply
remove the sampler from the pouch, record sampling information, and slide
the cover to the "on" or sampling position. Clip the sampler
on a worker for personal sampling up to eight hours. When
sampling is complete, slide the cover to the "off" position,
place the sampler back in the pouch immediately, and seal.
Send the sampler to an accredited laboratory for analysis by
solvent extraction ion chromatography (IC) with conductivity detection.
Performance Profile
| Sampling Rate |
SO2: 15.1 ml/min with a relative standard deviation of 16.7%
NO2: 12.83 ml/min with a relative standard deviation of 13.4% |
| Validated Concentration Range for SO2 and/or
NO2 |
0.4 to 8 ppm |
| Analysis Method for SO2 and/or
NO2 |
Solvent extraction and ion chromatography with conductivity detection |
| Lower Detection Limits for SO2 and/or
NO2 |
15 minutes: 2 ppm
8 hours: 0.1 ppm
|
| Shelf-life |
18 months from date of manufacture at ambient temperature |
| Storage |
Before use: Ambient temperature
After use: Analyze within 3 weeks.
Can be stored at ambient temperature
or at < 39.2 F (4 C) |
Accuracy for SO2 and/or NO2
|
± 30% |
| Temperature Effects |
No effect on sampling rate between 20 and 25 C |
| Humidity Effects |
No effect from 20 to 80% relative humidity |
| Wind Effects |
No effect from 0.05 to 1.0 m/s |
| Interferences |
None identified |
| Dimensions |
3.4 x 1.1 x 0.35 in
(8.6 x 2.8 x 0.89 cm) |
| Weight |
0.38 oz (10.9 gm) |
| Slide Cover |
Yellow |
Potential Sources of Workplace Exposure to Sulfur
Dioxide and Nitrogen Dioxide
Sulfur dioxide is used in industry as a(n):
- Intermediate in sulfuric acid manufacture
- Bleaching agent
- Disinfectant
- Fumigant
- Solvent
- Refrigerant
- Food preservative
- Reagent in the manufacture of magnesium, sodium sulfite, and other
chemicals
Other sources are:
- Copper smelting
- Processing or burning coal or fuel oil
- Paper manufacturing
- Fertilizer manufacturing
Nitrogen Dioxide is used in:
- Agricultural silos
- Arc or gas welding, especially in confined space
- Electroplating plants
- Food and textile bleaching
- Jewelry manufacturing
- Nitric acid production
- Nitrogen fertilizer production
- Nitro-explosive production
- Pickling plants
Source: OSHA Method ID-182
Other UMEX Passive Samplers Available
The same convenient and economical
UMEX design is also available for sampling formaldehyde/other
aldehydes
(UME 100) and amines (UMEX 400).
Ordering Information
| Description |
Cat. No. |
| UMEX 200 Passive
Sampler for Sulfur Dioxide and/or Nitrogen Dioxide, individually
packaged in aluminized pouch, pk/10
UMEX samplers are designed for single use only. Do Not reuse
UMEX samplers.
Limited shelf-life. Do not store with food.
|
|
UMEX
200 Product Data Bulletin (PDF)
UMEX
200 Performance Profile (PDF)
UMEX
200 Sulfur Dioxide Research Report (PDF)
UMEX 200 Nitrogen
Dioxide Research Report (PDF)
UMEX
200 Operating Instructions (PDF)
List
of Laboratories for Analyzing 500-200 Series UMEX Passive Samplers
This page was last modified April 19, 2010