SKC: Shaping the Future of Air Sampling  

 

 

DEFENDER
Primary Standard Calibrator
The Next Generation in Dry CalibrationDEFENDER Primary Standard Calibrator 717 series

Defender Spec. Sheet (PDF)

DEFENDER Primary Standard Calibrator CE Conformity Declaration (PDF)

CalChek with the Defender Operating Instructions (PDF)

  • Designed exclusively for the occupational health and safety industry and built on next-generation DryCal® technology!

  • Easy CalChek automatic calibration with AirChek 2000 and Leland Legacy pumps

  • Easy-to-use menu-driven system

  • Laboratory accuracy certified by NIST through NVLAP and backed by ISO 17025 accreditation, ANSI Z-540, and NIST Handbook 150
    • Volumetric accuracy is 1% of reading (510, 520, and 530 models)
    • Standardized accuracy is 1.2% (530 models)

  • Choice of 3 wide flow ranges
    • 5 to 500 ml
    • 50 ml to 5 liters
    • 300 ml to 30 liters

  • Easy jarless calibration for cyclones

  • Large illuminated graphical display with zoom feature

  • Sleek new design fits in a briefcase and weighs only 29 ounces (0.8 kg)

  • 520 models record ambient temperature and pressure for enhanced audit trail

  • New 530 models sense ambient temperature and pressure and standardized calibration readings

  • Optimizer Software for data transfer to a PC

  • RoHS compliant — lead-free components

    DEFENDER LCD Showing Menu System
  • Easy menu system:
    • Select single, continuous (hands-free), or time interval readings; display units; and other parameters
    • Auto shut-off

  • Sleek, robust design — only 29 ounces (0.8 kg)
    • Smooth molded case fits into a briefcase
    • Interior shock absorbers for field use
    • Improved internal valve design for greater reliability
    • Large illuminated flow cell viewing window

  • Integrated serial PC interface and software for data transfer to a PC
    • Optimizer Software (included) provides a link to your PC and automatically transfers readings to be saved as a text file

  • 520 model* contains automatic features for enhanced audit trail
    • Integrated temperature sensors and pressure transducers are directly in flow stream
    • Record ambient temperature and pressure data — no additional instruments needed
    • Enhance audit trail by including temperature and pressure conditions during air sampler calibrations

  • 530 model standardizes or corrects flow to ambient temperature and pressure conditions
* Defender 520 model documents temperature and pressure for audit trail. Choose Defender 530 for flow-calibration corrected to these parameters

 

Three DEFENDER Models to Meet Your Applications

DEFENDER Primary Standard Calibrator 717 series

Defender 510: 1% accuracy volumetric calibration for personal air samplers and other volumetric instruments

Defender 520: with 1% volumetric accuracy, Defender 520 also records ambient temperature and pressure at time of calibration for enhanced audit trail

Defender 530: 1% accuracy volumetric and 1.2 % accuracy standardized calibration for environmental applications and calibrating mass flow meters and controllers


Laboratory and Defender Accuracy

Laboratory accuracy is certified by NIST through NVLAP and backed by ISO 17025 accreditation. Volumetric accuracy for the Defender 510, 520, and 530 models is 1% of reading. The Defender 530 also features a standardized accuracy of 1.2%.

Description
Flow Range
(ml/min)
Cat. No.
Defender 510 Model includes lead-acid battery, multi-plug charger (100-240 V), Optimizer Software, 39-inch (1-meter) serial cable, and leak test caps
Software requires Windows® 2000, XP (sp 2 or 3), or Vista (32-bit version) and RS-232 port or USB to RS-232 adapter.
5 to 500
50 to 5000
300 to 30,000
Defender 520 Model includes lead-acid battery, multi-plug charger (100-240 V), Optimizer Software, and 39-inch (1-meter) serial cable, and leak test caps
Software requires Windows® 2000, XP (sp 2 or 3), or Vista (32-bit version) and RS-232 port or USB to RS-232 adapter.
5 to 500
50 to 5000
300 to 30,000
Defender 530 Model includes lead-acid battery, multi-plug charger (100-240 V), Optimizer Software, 39-inch (1-meter) serial cable, and leak test caps
Software requires Windows 2000, XP (sp 2 or 3), or Vista (32-bit version), and an RS-232 port or USB to RS-232 adapter.
5 to 500
50 to 5000
300 to 30,000
Accessories
Cat. No.
Replacement Lead-acid Battery Pack
Defender Universal Charger, 100-240 V, with U.S., Euro, and Australia plugs
Defender Universal Charger, 100-240 V, with U.S. plug
Pelican Carry Case with customized foam for single Defender, black
Nylon Carry Case with padded detachable shoulder strap, for single Defender, black
Leak Test Caps for Defender Calibrators, plastic caps for suction and pressure fittings during self leak test, pk/10
Tubing Kit for Defender Calibrator includes 3.9-inch (10-cm) Tygon tubing (1/4-inch ID, 3/8-inch OD), 3.9-inch (10-cm) silicone tubing, and screw fitting adapter
RS-232 Serial Card, detachable cable, RoHS compliant
The manufacturer supports use of this serial card only.
CalChek Communication Cable, for use with AirChek 2000 or Leland Legacy Pumps, allows for direct communication between a CalChek-compatible AirChek 2000 or Leland Legacy pump and a CalChek-capable BIOS Defender primary standard calibrator
Note: For use only with Defender calibrators with Revision Level C or higher
Defender Electronic Calibrator Kwik-Klip Video

Tubing Page

Defender Spec. Sheet (PDF)

DEFENDER Primary Standard Calibrator CE Conformity Declaration (PDF)

CalChek with the Defender Operating Instructions (PDF)


This page was last modified February 11, 2010
  About SKC Terms of Use Privacy Policy Contact Us Ordering Information

This site was last modified March 10, 2010

SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2000
© Copyright 1995-2010 SKC Inc