Humidity STICK
Digital Hygrometer
Highly accurate; NIST-certified calibration
- Wide measuring range
- Measure temperature and relative humidity
- Dew point model provides dew point calculations
- Wet bulb model displays wet bulb temperature
Economical
Patented "drift-free" humidity sensor
- Long-term stability
- Unaffected by water
Easy to use
- One-button operation
- Includes pocket clip and duct holder
- Auto-off function
- Patented swiveling head provides easy viewing of LCD
Small and lightweight
Ideal for use in schools, workplace, and public buildings
|
Relative Humidity STICK
(Cat. No. 751-6054) features swiveling
head for easy viewing |
Applications
- Ambient condition monitoring
- Indoor Air Quality (IAQ) studies
- Measuring air conditioning ducts
- Monitoring air humidity in greenhouses
- Checking storage conditions for food
- Monitoring aging process in cheese
Relative Humidity STICKs are the portable, low-cost solution for
easy relative humidity (RH) measurements in schools, public buildings,
and the workplace. Fast, accurate measurements display on the patented
swivel head LCD for easy viewing. Relative Humidity STICKs measure
and display relative humidity from 5 to 95%, temperature from 32
to 122 F, calculated dew point from -4 to 122 F td (dew point model
751-6053), and wet bulb temperature from 10 to 160 F (wet bulb model
751-6054). The 1/2-inch probe head fits conveniently in a duct or
is useful to test indoor and outdoor ambient spaces.
Relative Humidity and Dew Point
Relative humidity (RH) is the ratio
between the actual amount of water vapor in air versus the potential
amount of water vapor
that can be held in air at a specific temperature. RH is reported
as a percentage. Dew point temperature is the temperature at which
air becomes saturated with water and condensation begins to form.
Relative humidity is at 100% and the ambient air temperature equals
the dew point temperature when this occurs. Relative humidity plays
an important role in indoor air quality, occupant comfort, and production
processes. Therefore, it should be monitored on a regular basis.
Performance Profile
| Storage temperature: | -4 to 158 F (-20 to 70 C) |
| Operating temperature: | 32 to 122 F (-1.7 to 50 C) |
| Battery: | 3 AAA-type alkaline |
| Battery life: | 1000 hrs |
| Weight: | 2.7 oz (.08 kg) |
| Dimensions: | 7 x 1.5 x 1.4 in (17.8 x 3.8 x 3.6 cm)
|
Humidity Probe type - Capacitive |
| Measuring range: | 5 to 95% RH |
| Accuracy: | ± 3% RH (5 to 95% RH) |
| Resolution: | 0.1% RH |
| Units: |
Dew point (751-6053)
% RH
Wet bulb (751-6054)
|
Temperature Probe type -Negative Temperature Coefficient
(NTC) |
| Measuring range: | 32 to 122 F (-1.7 to 50 C) |
| Accuracy: | ± 0.9 F |
| Resolution: | 0.2 F |
| Units: | C/F |
Ordering Information
| Description |
Cat. No. |
| Relative Humidity STICK (dew point) with
duct holder, belt clip, and battery |
|
| Relative Humidity STICK (wet bulb) with
duct holder, belt clip, and battery |
|
This page was last modified July 20, 2009
|