Humidity STICK
Digital Hygrometer


  • Highly accurate; NIST-certified calibration

  • • Wide measuring range
    • Measures temperature, humidity, and dew point
    • Provides dew point calculations

  • Economical


  • Patented "drift-free" humidity sensor

  • • Long-term stability
    • Unaffected by water

  • Easy to use

  • • One-button operation
    • Includes pocket clip and duct holder
    • Auto-off function
    • Pivoting head provides easy viewing of LCD

  • Small and lightweight


  • Ideal for use in schools, workplace, and public buildings
Humidity STICK  Digital Hygrometer Cat. No. 751-605
Humidity STICK  Digital Hygrometer Cat. No. 751-605

Applications

  • Ambient condition monitoring

  • Indoor Air Quality (IAQ) studies

  • Measuring air conditioning ducts

  • Monitoring air humidity in greenhouses

  • Checking storage conditions for food

  • Monitoring aging process in cheese

The Humidity STICK combines a patented "drift-free" humidity sensor, portability, and low cost in one easy-to-use instrument. A quick-action display shows relative humidity (% RH), temperature, and calculated dew point measurements. The display is mounted in a patented swivel head for easy viewing. A rotating cap protects the sensor when the instrument is not in use. One three-volt battery provides approximately 200 hours of operation. The stable Humidity STICK sensor will provide years of use.

Relative Humidity and Dew Point

Relative humidity (RH) is the ratio between the actual amount of water vapor in air versus the potential amount of water vapor that can be held in air at a specific temperature. RH is reported as a percentage. Dew point temperature is the temperature at which air becomes saturated with water and condensation begins to form. Relative humidity is at 100% and the ambient air temperature equals the dew point temperature when this occurs. Relative humidity plays an important role in indoor air quality, occupant comfort, and production processes. Therefore, it should be monitored on a regular basis.

Performance Profile

Measuring range: 5 to 95% RH, -4 to 160 F
Measuring parameters: % RH/C/F/dew point
Resolution: 0.1% RH/0.1 F
Accuracy: ± 3% RH/± 0.5 F
Operating temperature: 32 to 122 F
Storage temperature: -4 to 160 F
Battery: 3-V button cell
Battery life: Approx. 200 hrs
Probe stem: Diameter: 0.5 inches
Length: 5 inches
Auto off: Approx. 10 min

Ordering Information          

  Description Cat. No.
Relative Humidity STICK (dew point) with battery 751-605
Relative Humidity STICK (wet bulb) with battery 751-6052