HAZ-DUST I Real-time Particulate Monitor
Portable PM Survey Tool
HAZ-DUST
I Downloads
- Easy operation and instantaneous readings in mg/m3
- Selectable dual measuring range feature
• Particulate concentration measurements between 0.01
and 20 mg/m3 and
from 0.1 to 200 mg/m3
- Easy-to-read digital display
- Highly sensitive — measures down to 0.01 mg/m3
• Monitors OSHA/NIOSH reference methods
- Rechargeable, 8-hour battery
• Low battery indicator
- Unique design provides protection from RFI/EMI; CE Marked
- Lightweight, rugged, and portable
- Optional tripod mounting
- Optional datalogger with user-selectable alarm threshold
- Easy-to-use DustComm Pro Software available with datalogger
for downloading, time vs. concentration profiling, and comprehensive
graphical reporting
With the touch of a button, the portable HAZ-DUST I real-time particulate
monitor provides accurate and instantaneous data on airborne particle
concentration calculation. Designed for industrial hygiene,
indoor air quality, and hazardous materials investigations, HAZ-DUST
I is a cost-effective PM screening tool for passive dust measurements.
The HAZ-DUST
I Advantage
- Saves time and money: No cassettes to purchase
or weigh and no lab analysis needed
- Immediate results: Turn on HAZ-DUST I and the
reading is displayed
- Flexibility: Hand-held for survey monitoring
or add optional datalogger for continuous unattended monitoring
HAZ-DUST I Applications
HAZ-DUST I is ideal for industrial and remedial particulate air monitoring applications, such as:
- Determining level of respiratory protection
- Survey of workplace for OSHA/EPA compliance
- Qualifying off site particulate migration
- Surveying for PM-10 and TSP levels
- Monitoring dust generation during drilling/excavation
- Evaluating dust generation/suppression
- Locating/identifying "hot spots"
- Emergency Response and SARA Title III fugitive emissions compliance
- OSHA and EPA personal and ambient particulate air sampling
Principle of Operation
HAZ-DUST I uses the principle of near-forward light scattering to measure dust
concentration. Inside the instrument, an infrared light source is positioned
at a 90-degree angle from a photodetector. As airborne particles enter the
infrared beam, they scatter the light. The amount of light received by the
photodetector is directly proportional to the aerosol concentration. No filter
or gravimetric analysis is required. Air flow through the HAZ-DUST I is passive.
A Note about Calibration
The HAZ-DUST I is factory calibrated for respirable
particulate mass (size range 0.1 to 50 µm) with a 50% cut-point
of 4.0 µm (± 10% with SAE fine test dust), which falls under the ACGIH/
ISO/CEN criteria. Alternate calibration for thoracic particulate
mass with a 10-µm cut-point is available as a special order.
Optional Datalogger
For maximum automation of data collection, use the HAZ-DUST I Dust Monitor
with the optional datalogger to provide data storage, on-screen display of
statistics, and a user-selectable alarm threshold. The datalogger includes
DustComm Pro Software for PC that provides statistical analysis, graphs,
and detailed reports that can be printed for record keeping.
Performance Profile
| Sensing range |
0.01 to 200 mg/m3 |
| Display |
LCD 3.5 digits mg/m3 concentration reading |
| Calibration |
SAE fine test dust compared with NIOSH 0600 |
| Particle size range |
0.1 to 50 µm |
| Precision |
± 0.02 mg/m3 |
| Accuracy |
± 10% to NIOSH 0600 |
| Power |
NiMH rechargeable battery |
| Operating time |
> 8 hrs |
| Charging time |
10 to 12 hrs |
| Humidity |
95% non-condensing |
| Dimensions |
9 x 2.75 x 1.5 in
(22.9 x 7.0 x 3.8 cm) |
| Weight |
1.10 lbs (0.5 kg) |
| Optional datalogger |
Two-key programmable operation. Real-time clock, display, and
user-selectable alarm threshold. Includes software for statistics,
graphs, and reports. PC-compatible. |
| Recording time |
1 sec to 15 mos |
| Sampling rate |
1 sec, 10 sec, 1 min, 10 min, and 30 min averaging |
| Signal input |
0 to 2 volt |
| Output |
RS-232C (9600 baud rate) |
Ordering Information
Description |
Cat. No. |
| HAZ-DUST I Monitor, 110-240
V, includes battery, charger (110-240
V), and carry case
Requires calibration with equipment that is
sold separately, see accessories |
770-1100 |
| Accessories |
| Datalogger, provides data
storage, on-screen display of statistics, and user-selectable
alarm threshold,
includes analog signal cable, computer interface cable,
and DustComm Pro Software, printer required for hard
copy reports. |
770-113 |
| Tripod Stand, adjustable stand and
mounting plate for unattended monitoring |
770-129 |
| Calibration Standard, light scattering
device provides a constant value for verifying calibration |
770-102 |
| Zeroing Accessory, for
pumping filtered air into a sensor for a zero reading in
contaminated environments |
770-130 |
| Replacement Battery Pack, NiMH |
770-108 |
| Charger 110-240 V |
770-131 |
| Replacement Battery Pack for HAZ-DUST I Datalogger |
770-127 |
| Analog Signal Cable for HAZ-DUST I Datalogger |
770-107 |
HAZ-DUST
I Spec. Sheet (PDF)
HAZ-DUST
I Operating Instructions (PDF)
HAZ-DUST is a Trademark of Environmental Devices Corporation.
This page was last modified January 17, 2012
|