![]() Calibration Span Reference for HAZ-DUST IV and VDM-7500 Operating Instructions (PDF)
Easily interchangeable sampling heads for true breathing zone measurements of specific fractions
In-line cassette directly behind sensor for concurrent filter sampling
User comfort
Easily download data to a PC
Easy-to-use HAZ-DUST IV HAZ-DUST IV Sampling Heads
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Inhalable — SKC IOM Sampler SKC IOM Sampler Cat. No.
770-115A |
|
||
Thoracic — HAZ-DUST IVsampling head included with the HAZ-DUST IV |
![]() ![]() |
||
Respirable — SKC GS-3 CycloneSKC
GS-3 Cyclone Cat. No. 225-103 |
![]() ![]() |
||
HAZ-DUST IV operates on the principle of near-forward light
scattering of infrared radiation. It immediately and continuously
measures the concentration of airborne dust particles and displays the
result in mg/m3.
What is near-forward light scattering? This measurement technique
uses an infrared light source positioned at a 90-degree angle from a photodetector.
As the airborne particles enter the infrared beam, they scatter the
light. The amount of light received by the photodetector is directly
proportional to the aerosol concentration. Unique signal processing
internally compensates for noise and drift.
| Accuracy: | ± 10% to filter gravimetric SAE fine test dust |
| Sensing Range: | 0.01 to 200 mg/m3 |
| Particulate Size Range: | 0.1 to 100 µm |
| Precision: | ± 0.02 mg/m3 |
| Calibration: | NIOSH Method 0600 gravimetric reference - NIST-traceable SAE fine test dust |
| Sample Flow Rate: | 1.0 to 3.3 L/min |
| Power: | Rechargeable NiMH battery |
| Operating Time: | > 8 hours |
| Charging Time: | 10 to 12 hours |
| Data Storage: | 21,500 data points |
| Digital Output: | RS-232 |
| Dimensions: | Case: 5.5 x 3.25 x 2.75 in (14 x 8.3 x 7 cm) |
| Sensor: | 1.75 x 1.5 in (4.4 x 3.8 cm) |
| Weight: | 2 lbs (0.9 kg) |
| Description | Cat. No. |
HAZ-DUST IV Monitor 110-240V includes monitor,
thoracic head, in-line filter cassette, carry
case, computer cable, battery charger,
HAZ-DUST Media CD with instruction manual,
and DustComm Pro Software |
770-4004 |
| HAZ-DUST IV Inhalable, Thoracic, and Respirable Monitor Kit 110-240V includes monitor with thoracic head, in-line filter cassette, GS Cyclone and adapter, IOM and adapter, calibration jar and standard, carry case, computer cable, battery charger, HAZ-DUST Media CD with instruction manual, and DustComm Pro Software | 770-4004K |
| Sampling Heads | Cat. No. |
| Inhalable Sampling Head, IOM Sampler, mounts on HAZ-DUST IV sensor | 770-115A |
| Thoracic Sampling Head, mounts on inlet or HAZ-DUST IV sensor | |
| Respirable Sampling Head, GS-3 Cyclone, mounts on HAZ-DUST IV sensor | 225-103 |
| Adapter for GS-3 Cyclone Respirable Sampling Head, required when using GS-3 Cyclone | 770-313 |
| Accessories | Cat. No. |
| Calibration Standard for Monitor, for verifying span and optical sensor performance | 770-140 |
| Calibration Chamber, for calibrating and setting pump airflow when using respirable sampling head | 225-112 |
| Zeroing Accessory, for clean-air zeroing of HAZ-DUST IV sensor when using inhalable sampling head | |
| Zeroing Filter, for use with respirable and thoracic sampling heads | |
| Replacement Battery Pack, NiMH | |
| Charger 110 V | 770-4104 |
| Charger 240 V | 770-4104B |
| HAZ-DUST IV Accessories Adapter, adapts new HAZ-DUST IV accessories to units with serial numbers prior to 08070000 | 770-104 |
Calibration Span Reference for HAZ-DUST IV and VDM-7500 Operating Instructions (PDF)
|
||||||
|
This site was last modified March 19, 2010 © Copyright 1995-2010 SKC Inc |