Designed for use with a personal air sampling pump, long-duration color detector tubes are used for on-the-spot Time-Weighted Average (TWA) measurements. The tube is attached to a worker's collar and the sample pump pulls the air sample through the tube at a constant rate (20 ml/min) during the sampling period. At the conclusion of the testing period, the total volume is calculated (rate [ml/min] x time [min]). Chemical concentration is read directly from the tube. The TWA in parts per million (ppm) is readily calculated using the instructions that accompany the tubes.

Long Range Detector Tubes                 Online Ordering

Chemical Hazard Measuring Range (ppm) No. Test Cat. No
Ammonia 2.5 - 100 10 800-28231
Carbon dioxide 250 - 6,000 10 800-28611
Carbon monoxide 6.25 - 500 10 800-28121
Carbon monoxide 2.5 - 100 10 800-28741
Hydrocarbons 25 - 3,000 10 800-28571
Hydrogen sulfide 0.63 - 60 10 800-28141
Nitrous fumes 1.25 - 50 10 800-28911
Sulfur dioxide 0.5 - 20 10 800-28921
Accessories Cat. No
Tandem tube holder 222-3D-1
Trap tubes, pkg 10 222-3D-2


Pump Kit for Long-duration Tube Sampling
Includes AirChek® 52  Personal Sample Pump, low flow constant pressure controller, single charger, adjustable low flow holder attached to a type "T" cover, trap tubes, tool kit, and carry case.
Cat. No..................... 224-52LTK

Download Drager price list PDF




When sampling with long-duration color detector tubes, use trap tubes to protect the sample pump from chemicals that may be generated by the detector tube during sampling. At least One trap tube is recommended for each long-duration tube. The SKC tandem tube holder accommodates one long-duration tube and one trap tube.


Tandem Tube Holders
Tandem style for color detector tubes up to 115 mm long and a trap tube.
Cat. No..................... 224-29T

Trap Tubes
SKC trap tubes protect the sample pump from chemicals that may be generated from a long-duration color detector tube during the sampling period. One trap tube is recommended for each long-duration tube. Package of 10.
Cat. No..................... 222-3D-2

Contact your local SKC representative for information on other sampling pumps for long-duration tube sampling.


This page was last modified May 17, 2005
  About SKC Terms of Use Privacy Policy Contact Us Ordering Information

This site was last modified May 9, 2008

SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2000
© Copyright 1995-2008 SKC Inc