DrägerSensor Selection Guide
For Dräger Portable Gas Detection Instruments

XS Sensors
Dräger replacement XS sensors for Pac III, MiniWarn,
and X-am 7000 monitors
| Chemical |
Range |
Warranty |
Replacement
Cat. No. |
| Amines |
0 - 100 ppm |
1 year |
|
| Ammonia |
0 - 200 ppm |
1 year |
|
| Carbon dioxide |
0 - 5 Vol. % |
1 year |
|
| Carbon monoxide |
0 - 2000 ppm |
3 years |
|
Carbon monoxide HC
(high concentration) |
0 - 10,000 ppm |
1 year |
|
| Chlorine |
0 - 20 ppm |
1 year |
|
| Chlorine dioxide |
0 - 20 ppm |
1 year
|
|
Hydrides
(phosphine, etc.) |
0 - 20 ppm |
1 year |
|
| Hydrogen |
0 - 2000 ppm |
1 year |
|
Hydrogen HC
(high concentration) |
0 - 4 Vol. % |
1 year |
|
| Hydrogen cyanide |
0 - 50 ppm |
1 year |
|
| Hydrogen sulfide |
0 - 100 ppm |
3 years |
|
Hydrogen sulfide HC
(high concentration)
|
0 - 100 ppm |
1 year |
|
| Hydrogen sulfide XS-2 SR |
0 - 100 ppm |
1 year |
|
| Nitric oxide |
0 - 200 ppm |
1 year |
|
| Nitrogen dioxide |
0 - 50 ppm |
1 year |
|
Odorant
(mercaptan) |
0 - 40 ppm |
1 year |
|
| Organic vapors (OV) |
0 - 200 ppm |
1 year |
|
| Organic vapors (OVA) |
0 - 100 ppm |
1 year |
|
| Oxygen |
0 - 25 Vol. % |
3 years |
|
| Oxygen (XS-100) |
0 - 25 Vol. % |
1 year |
|
| Phosgene |
0 - 3 ppm |
6 mos. |
|
Phosphine HC
(high concentration) |
0 - 1000 ppm |
1 year |
|
| Sulfur dioxide |
0 - 100 ppm |
1 year |
|
ABOUT Dräger XS Sensors
For extra stability, use interchangeable user-replaceable
electrochemical XS sensors for the Pac III, MiniWarn, and X-am 7000
gas monitors to measure over 50 different gases and vapors. Dräger
XS sensors feature built-in gas-specific intelligence, superior temperature
stability, pressure compensation, minimum cross-sensitivity to background
gases, and constant validation of sensor performance. These sensors
require less frequent calibration compared to other electrochemical
sensors. Calibrated XS sensors can be transferred from unit to unit
without recalibration. Carbon monoxide, hydrogen sulfide, and oxygen
versions of the XS sensors carry a three-year warranty and only require
annual
recalibration.
Dräger XS-R Sensors
The latest generation of intelligent electrochemical DrägerSensors® offer
all the technical advantages of the XS sensors, but feature a 5-year
warranty. Available for CO, H2S, and O2,
they are compatible with the Pac III, MiniWarn, and
X-am 7000 monitors.
Replacement XS-R Sensors
All the technological advantages of XS Sensors with a 5-year warranty,
for Pac III, MiniWarn, and X-am 7000
| Chemical |
Range |
Warranty |
Replacement
Cat. No. |
| Carbon monoxide |
0 - 2000 ppm |
5 years |
|
| Hydrogen sulfide |
0 - 100 ppm |
5 years |
|
| Oxygen |
0 - 25 Vol. % |
5 years |
|
Dräger XS-2 Sensors
The new XS-2 family of CO, H2S, and O2 electrochemical
DrägerSensors offer:
- Complete compatibility and interchangeability with Pac III, MiniWarn,
and X-am 7000
- 2-year warranty, even for O2
- Economy
Economical intelligent sensors with at 2-year warranty, for Pac III, MiniWarn,
and X-am 7000
| Chemical |
Range
|
Warranty
|
Cat. No.
|
| Carbon monoxide |
0 - 2000 ppm |
2 years
|
|
| Hydrogen sulfide |
0 - 100 ppm |
2 years
|
|
| Oxygen |
0 - 25 Vol. % |
2 years
|
|
Replacement XXS Sensors
High sensitivity, miniature size, long life for Pac 7000,
X-am 2000, and X-am 5000
| Chemical |
Range |
Warranty |
Cat. No. |
Ammonia
(Pac 7000 and X-am 5000
only) |
0 - 300 ppm |
1 year |
|
Carbon dioxide
(Pac 7000 and X-am 5000
only) |
0 - 5 Vol. % |
1 year |
|
| Carbon monoxide |
0 - 2,000 ppm | 2 years
|
|
| Carbon monoxide/Hydrogen sulfide |
CO 0 - 2000 ppm
H2S 0 - 200 ppm |
1 year |
|
Chlorine
(Pac 7000 and X-am 5000
only) |
0 - 20 ppm |
1 year |
|
Hydrogen cyanide
(Pac 7000 and X-am 5000
only) |
0 - 50 ppm |
1 year |
|
| Hydrogen sulfide |
0 - 200 ppm |
2 years
|
|
Hydrogen sulfide LC
(Pac 7000 and X-am 5000
only) |
0 - 100 ppm |
1 year |
|
Nitrogen dioxide
(Pac 7000 and X-am 5000
only) |
0 - 50 ppm |
1 year |
|
| Oxygen |
0 - 25 Vol. % |
2 years
|
|
Organic vapor (OV)
(Pac 7000 and X-am 5000
only) |
0 - 200 ppm |
1 year |
|
Organic vapor (OV-A)
(Pac 7000 and X-am 5000
only) |
0 - 200 ppm |
1 year |
|
Phosphine
(Pac 7000 and X-am 5000
only) |
0 - 20 ppm |
1 year |
|
Sulfur dioxide
(Pac 7000 and X-am 5000
only) |
0 - 100 ppm |
1 year |
|
X-am Dräger XS Sensors
X-am 3000 gas sensors are a variation of Dräger XS Sensors and perform
for > 2 years with six-month calibration intervals.
| X-am Dräger XS Sensors |
Range |
Warranty
|
Cat. No. |
Carbon monoxide
(X-am 3000 only) |
0 - 999 ppm |
2 years
|
805-10030 |
Hydrogen sulfide
(X-am 3000 only) |
0 - 99 ppm |
2 years |
805-10032 |
Oxygen
(X-am 3000 only) |
0 - 25 Vol. % |
2 years |
805-10034 |
X-am Dräger Cat Ex Sensors
| X-am Dräger Cat Ex 2 Sensor |
Range |
Warranty
|
Cat. No. |
Cat Ex 2
(X-am 3000 only) |
0 - 100% LEL
0 - 100 Vol. % |
2 years
|
|
|
Cat Ex
Combustible replacement sensor
(MiniWarn only)
|
0 - 9900 ppm
0 - 100% LEL
0 - 100 Vol. %
|
2 years
|
|
|
Cat Ex FR
Combustible replacement sensor
(MiniWarn only)
|
0 - 9900 ppm
0 - 100% LEL
0 - 100 Vol. %
|
1 year
|
|
New!
t Ex 125PR
Combustible replacement sensor
(X-am 2000, X-am 1700, and X-am 5000 only)
Use of
this sensor requires X-am 1700/2000/5000 firmware update to versions
>4.0 and updated versions of CC-Vision or GasVision for X-am 1700/2000 |
0 - 100% LEL
0 - 5 Vol. %
0 - 100 Vol. %
|
2 years
(3 years X-am 2000) |
|
Smart Cat Sensors
Measure a wide range of combustible gases/vapors with the X-am 7000 Smart
Cat Sensors. All combustibles readily oxidized by the catalyst will respond
to the sensor at different
sensitivities.
| Dräger Smart Cat Sensors |
Range |
Warranty |
Cat. No.
|
Smart Cat Ex
(X-am 7000 only) |
0 - 9900 ppm
0 - 100% LEL
0 - 5 Vol. % |
2 years |
|
Smart Cat Ex HC
(X-am 7000 only) |
0 - 9900 ppm
0 - 100% LEL
0 - 100 Vol. % |
2 years |
|
Smart Cat Ex FR
(X-am 7000 only) |
0 - 9900 ppm
0 - 100% LEL
0 - 5 Vol. % |
2 years |
|
Smart Infrared (IR) Sensors
X-am 7000 Smart Sensors are extremely accurate and do not have cross sensitivities
to other gases.
| Dräger Smart Infrared (IR) Sensors |
Range |
Warranty |
Cat. No.
|
Smart Ex-IR
(X-am 7000 only) |
0 - 9900 ppm
0 - 100% LEL
0 - 100 Vol. % |
5 years |
|
Smart IR-Carbon Dioxide
(X-am 7000 only) |
0 - 9900 ppm
0 - 5 Vol. % |
5 years |
|
Smart IR-Carbon Dioxide, HC
(X-am 7000 only) |
0 - 9900 ppm
0 - 100 Vol. % |
5 years |
|
PID Sensor
The X-am 7000 PID sensor detects low levels of broadband toxics or VOCs.
| Dräger PID Sensor |
Range |
Warranty
|
Cat. No.
|
Smart PID
(X-am 7000 only) |
0 - 5000 ppm |
2 years
(sensor only, not lamp) |
|
Replacement PID Lamp, 10.6 ev
(X-am 7000 only) |
|
1 year |
|
This page was last modified February 1, 2012
|