Leland Legacy Spec. Sheet (PDF) Leland Legacy Operating Instructions (PDF) Leland Legacy Quick Guide (PDF) Battery Pack for Leland Legacy Sample Pumps Operating Instructions (PDF) Technical Note: SKC Sample Pump Battery Pack Characteristics and Maintenance (PDF) Download DataTrac for the Leland Legacy DataTrac Operating Instructions (PDF) Leland Legacy EMC Test Certificate (PDF) High flows from 5 to 15 L/min
Typical Run Time†
Low Levels Low Noise ** Measured
3 ft (1 m) from pump operating at 10
L/min without media Flexible programming
Accurate automatic calibrationThe patented (U.S. Patent No's. 6,227,031 and 6,363,769) built-in CalChek feature provides direct communication to a Defender primary standard for fast and easy calibration without manual adjustments. The Defender Calibrator is sold separately or available in convenient Leland Legacy CalChek pump kits. Leland Legacy Sampler ApplicationsUse in non-explosive environments only.
The Leland Legacy AdvantageCollects more sample Designed for indoor
environments Downloadable history Leland Legacy and Sioutas Impactor*
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Flow Range | 5 to 15 L/min | ||||
| Closed loop with patented internal
flow sensor U.S. Patent No. 5,892,160 |
|||||
| Compensation Range | 15 L/min at 5 inches water back pressure 10 L/min at 12 inches water back pressure 5 L/min at 20 inches water back pressure |
||||
| Accuracy |
Flow rate: ± 5% of set-point after calibration to desired flow | ||||
| Accuracy |
Timing: 1 min/month at 25 C | ||||
| Accuracy | Atmospheric Pressure: ± 0.3 in Hg | ||||
| Flow Fault | If the pump is unable to compensate for > 15 seconds due to excessive back pressure, a flow fault icon displays and flashes, the pump enters Hold mode, and the pump retains historical data. Auto restart is attempted every 20 seconds up to 10 times. Adjustable with DataTrac for Leland Legacy software | ||||
| Display | LCD, displays pump serial number, pump software revision level, flow rate, volume, temperature, atmospheric pressure, time of day, run time, and pump status, i.e., hold and run as well as Setup information | ||||
| Volume Display | Continually updated, based on corrected flow rate multiplied by sampling time | ||||
| Time Display | Time of day in hours and minutes (12 or 24-hour clock) with AM and PM indicators | ||||
| Timer Display Range | 1 to 99999 minutes (69 days). If the run time exceeds 69 days, the timer display rolls over. | ||||
| Operating Temperature Range | 32 to 113 F (0 to 45 C) Protect sample pump from weather when in use outdoors. |
||||
| Typical Run Time |
24+ hours:
|
||||
| Noise Level | 62.5 dBA — pump without case 52 dBA — pump housed in noise-reducing case (optional accessory Cat. No. 224-89) measured 3 ft (1m) from pump operating at 10 L/min without media. |
||||
| User-adjustable Values | Sample run time, calibration, clock display, flow rate, time of day, delayed start, and temperature and atmospheric pressure display | ||||
| Recorded Values | Start date and time, stop date and time, total sample time, flow rate, sample volume, temperature, atmospheric pressure, and pump mode transitions | ||||
| Adjustable Logging Interval | Records pump history from 3 seconds (15.4 min. of data) up to 8 hours (over 102 days of data) depending on setting. Option available when using DataTrac Software. | ||||
| Power Supply | Battery: removable, rechargeable lithium-ion (Li-Ion) battery
pack 7.2 V x 10
Ah capacity (See Li-Ion Battery Shipment below) Charger/AC adapter: input voltage 100 to 240 V AC |
||||
| Battery Recharge Time | 15 hours | ||||
| Temperature: Charging | 32 to 113 F (0 to 45 C) | ||||
| Temperature: Storage | -4 to 113 F (-20 to 45 C) | ||||
| Size | 8 x 3.9 x 2.6 in (20 x 10 x 7 cm) | ||||
| Weight | 37 oz (1 kg) | ||||
| Case | Thermoplastic with soft rubber over-molding | ||||
| RFI/EMI Shielding | CE marked |
| Pump Kits and Accessories* Use in non-explosive environments only; not UL Listed for intrinsic safety Leland Legacy Pumps contain Li-Ion batteries and may be subject to special shipping regulations dependent upon quantity. |
Cat. No. | |
| Leland Legacy Pump†* with
Li-Ion battery pack, Use in non-explosive environments only; not UL Listed for intrinsic safety; CE marked Requires charger; see kits or accessories below |
||
| Single Pump Kit†* includes
Leland Legacy pump, Li-Ion battery pack, single charger/adapter unit, and
deluxe carry case, CE marked Use in non-explosive environments only; not UL Listed for intrinsic safety |
||
Single Pump CalChek Kit† includes
Leland Legacy pump, Li-Ion battery pack,
single charger/adapter unit, Defender Calibrator (Revision Level
C, CalChek ready) with charger and CalChek communication cable,
and Pelican carry case. CE marked |
100-240V |
|
| 5-pack Pump Kit†*includes
5 Leland Legacy pumps, 5 single charger/adapter units,
and DataTrac Software in a deluxe Pelican carry case. CE marked Use in non-explosive environments only; not UL Listed for intrinsic safety |
100-240V |
|
| 5-pack CalChek Kit† includes
5 Leland
Legacy pumps, CalChek Kits, Li-Ion battery packs, single
charger/adapter units, DataTrac Software,and Defender Calibrator
(Revision Level C, CalChek
ready) with charger and CalChek communication cable, and deluxe Pelican
carry case. CE marked Use in non-explosive environments only; not UL Listed for intrinsic safety |
100-240V |
|
| Certificate of Compliance, optional, must be ordered when ordering pump. | P1501 | |
| Accessories | ||
| Defender Primary Standard Calibrator Model
510, 300-30,000 ml/min Includes lead-acid battery, charger (100-240),
Optimizer 110 software, and 1-meter serial cable Software requires Windows 2000 SP3 or XP SP2 and available COM port on PC. |
||
| CalChek Communication Cable,
provides direct communication between a CalChek-compatible AirChek 2000
or Leland Legacy pump and a CalChek-capable
Defender primary standard calibrator Note: For use only with Defender calibrators with Revision Level C or higher |
210-502 | |
| Replacement Defender Lead-acid battery pack | ||
| Defender Universal Charger, 100 to 240 V, with U.S., Euro, and Australia plugs | ||
| Defender Universal Charger, 100 to 240 V, with U.S. plug | ||
| Single Pump Charger includes
charging unit and wall cube (100-240V worldwide power input with interchangeable plugs included) |
||
| Replacement Li-Ion Battery Charging Unit Cable, for charger 223-241 | P75632 | |
| Battery Charging Adapter, for charging batteries outside the pump | 223-248 | |
| Replacement Leland Legacy Battery Pack, Li-Ion | ||
| Replacement Filter/O-ring Set includes 5 inlet filters and 1 O-ring | ||
| Replacement Inlet Filters, pk/50 | ||
| Replacement PC Board, for Leland Legacy Sample Pump, main | P7954802 | |
| Replacement Inlet, for Leland Legacy Pump | P20198 | |
| Replacement Belt Clip, for Leland Legacy Pump | P51823 | |
| Noise-reducing Nylon Case, black, with lining to reduce pump noise
from 62.5 to 52 dB, includes
waist belt and shoulder strap Measured 3 ft (1 M) from pump operating at 10 L/min without media |
||
| DataTrac Software for Leland Legacy includes
software CD, adapter, and cable. Requires Windows 98 or higher |
||
| Leland Legacy Case includes front and back cases. Does not include serial number label | ||
| Leland Legacy Control Board | ||
| Leland Legacy Motor | ||
| Leland Legacy Inlet Side Pulsation Dampener | ||
Protect sample pump from weather when in use outdoors.
| * Rechargeable lithium-ion batteries
for use with SKC sampling pumps have been tested in accordance with the
UN Manual of Test and Criteria and are
designated as UN3091
For air shipments: For ground shipments: |
| † | Leland Legacy Pumps contain Li-Ion batteries and may be subject to special shipping regulations dependent upon quantity. |
Leland Legacy Spec. Sheet (PDF)
Leland Legacy Operating Instructions (PDF)
Leland Legacy Quick Guide (PDF)
Battery Pack for Leland Legacy Sample Pumps Operating Instructions (PDF)
Technical Note: SKC Sample Pump Battery Pack Characteristics and Maintenance (PDF)
Download DataTrac for the Leland Legacy
DataTrac Operating Instructions (PDF)
Leland Legacy EMC Test Certificate (PDF)
|
||||||
|
This site was last modified May 9, 2008 © Copyright 1995-2008 SKC Inc |