|
|
Low Flow Pumps
The Pocket Pump 210 Series
Programmable Low Flow Sampler
Ordering Information
Pocket
Pump Operating Instructions (PDF)
Pocket Pump Quick Guide (PDF)
Battery
Pack for Pocket Pump Operating Instructions (PDF)
Technical
Note: SKC Sample Pump Battery Pack Characteristics and Maintenance
(PDF)
UL
Certificate of Intrinsic Safety (PDF)
EMC
Test Certificate (PDF)
DataTrac
for the Pocket Pump
Instrucciones
de Funcionamento (PDF)
Téléchargement
Guide de I'utilisateur (PDF)
Advanced Technology in the Smallest Programmable
Low Flow Pump
Constant flows from 20 to 225 ml/min
Accommodates most flow rates for sorbent tubes
Compact and lightweight
Only 4.5 x 2.2 x 1.4 in (11.4 x 5.6 x 3.6
cm) and 5 oz (142 gm)
Easily fits into a shirt pocket or clips on a belt without protruding
Ultra-quiet operation
For greater worker acceptance
Two operating modes
Constant flow (single tube)
Constant pressure (multiple tube) with accessories saves time
and uses fewer pumps
PC-programmable with DataTrac Software
With optional DataTrac Software, program delayed, intermittent,
and repeated sampling
Download data to PC for documentation of sampling history, record
keeping, and data analysis
Electronic flow control; no tools required
Simple 3-button keypad does it all
Continuous sample volume calculations
Sampling parameters are continuously updated
Automatic features maintain sample integrity
Low battery or restricted flow shut off
Pump stores run time data in memory
Auto-restart after flow fault
RFI/EMI-shielded and CE marked
Flow unaffected by outside interferences
Accurate air volumes and data validity ensured
Extended run time with NiMH battery
Samples up to 12 hours on one battery charge with NiMH battery
Large easy-to-read LCD
Easily view sampling parameters and battery and fault status,
all at the touch of a button
Pump-controlled charging
Never overcharges
Built-in system automatically senses maximum charge and switches
to trickle charge to prolong battery life and prevent damage
Continuous run with AC adapter enables 24-hour
sampling
Useful for environmental monitoring or round-the-clock sampling
without harm to the battery pack
Security code system protects data
Requires code before changing operating parameters
Minimizes accidental changes or tampering and maintains
sample validity
Impact-resistant case
Rugged case withstands rough handling in the industrial
workplace
Intrinsically safe
UL and cUL Listed
ATEX-approved model available (NiCad battery model only)
Safe in explosive environments
Versatile for all industries
Ordering Information
 |
 |
The 3-button Keypad Does It All
Use the three buttons under the sliding cover to program the pump. Set the flow rate in constant flow mode for single sorbent tube applications, or set the back pressure in constant pressure mode for multiple sorbent tube applications. The Pocket Pump accommodates flow ranges for most sorbent tube and long-duration detector tube methods. Users may also select the temperature and pressure scale. To execute any command that would change the operating mode or a sampling parameter, a security code is required that minimizes tampering and maintains sample validity. The Pocket Pump may be placed in a HOLD state at any time without loss of data.
The Pocket Pump operates in either constant flow or constant pressure (multiple-tube
sampling) mode with flows from 20 to 225 ml/min. Operation is programmed using
the 3-button keypad or a personal computer through the interface module.
The Pocket Pump’s built-in security code system prevents a worker from changing
operating states or sample parameters, thus ensuring sample validity. Also,
multiple keys must be pressed to place the unit into a HOLD state; accidentally
pressing one button will not alter the operating state.
Direct Readout of Data
The large easy-to-read LCD shows direct readouts of sample data that is continuously
updated and may be displayed during sampling at the touch of a button.
Simply press a key to scroll through the sample data that includes flow rate,
air
volume,
temperature
of the incoming air, and sample time. The LCD constantly displays a battery
status icon, and a flashing flow fault icon appears when flow is restricted
or blocked.
Pump-controlled Charging
Never worry about overcharging again. Since advanced electronics are built into the pump and not the charger, the smart charging battery system knows how much charging the pump needs; it never overcharges. The batteries may be charged with the battery charger while the pump is running. The Pocket Pump may operate indefinitely with the AC charger/adapter without harm to the battery pack.
The battery charge status icon is constantly displayed. When the pump loses all charge, it enters the SLEEP mode while preserving the historical data in memory. When fully charged, the internal NiMH cells provide 12 hours of continuous use at 200 ml/min with back pressure at 10 inches of water. Run times vary with media used.
PC Programmable with DataTrac Software
Use DataTrac Software (optional accessory) and your personal computer to
make the Pocket Pump PC programmable. DataTrac simplifies chain-of-custody
reporting by allowing users to program up to 14 complete running sequences
including delayed start, timed stop, and intermittent sampling, all at different
flow rates. Pump settings can be changed with the click of a mouse button.
DataTrac’s Real-time Monitor window displays a real-time readout of the Pocket Pump’s
operations including time and sample volume. Lengthy calculations are unnecessary;
DataTrac does it all for you. The advanced information retrieval system is
specifically designed to store data and provide chain-of-custody information.
DataTrac also stores historical data in pump memory that can be retrieved
up to 24 hours after shutdown.
- Program the flow rate, start and stop date, and sample duration.
- Schedule multiple start and stop times.
- Create a sample setup sheet for worker, sample, and analysis information.
- Download historical records of flow rate, sample time, air volume, temperature, and more.
- Print or save a complete report of sample and pump history information.
Performance Profile
| Flow Range in Constant
Flow Mode |
20 to 225 ml/min
|
| Accuracy Variance Between
LCD Reading and Actual Flow Rate (after calibration) |
20 to 225 ml/min ± 5% |
| Constant Flow Compensation |
20 to 225 ml/min up to
20 inches water back pressure |
|
Flow Control
|
Holds constant flow to ± 5%
of set-point |
| Pressure Range in Constant
Pressure (Multiple-tube Sampling Mode) |
1 to 10 inches of water (1.87
to 18.7 mm Hg) at a maximum flow rate of 200 ml/min for 8
hrs (12 hrs if using NiMH battery)
10 to 20 inches water (18.7 to 37.4 mm Hg) at maximum flow rate of
100 ml/min for 8 hrs (12 hrs if using NiMH battery) |
| Constant Pressure (Multiple-tube
Sampling) Mode Accuracy |
Pressure reading ± 0.5 in
of water (0.25 mm Hg) |
| Operating Temperature |
20 to 110 F (-7 to 43 C) |
| Storage Temperature |
-40 to 113 F (-40 to 45 C) |
| Charging Temperature |
40 to 100 F (5 to 38 C) |
| Run Time |
Varies with flow rate and sampling
media in line
At 200 ml/min and 10 inches water back pressure,
nominal run
time is approximately 8 hrs.
At 200 ml/min and 20 inches
water back pressure, nominal run time is approximately 6
hrs.
Connected
to a charger, run time is indefinite.
Nickel Metal
Hydride (NiMH) batteries increase run times up to 12 hrs
in most sampling situations.
|
| Timer Display Range |
1 to 9999 minutes |
| Timing Accuracy |
± 1% |
| Flow Fault |
If the pump is unable to
compensate for longer than 15 seconds due to excessive back
pressure, the pump enters FLOW FAULT mode. The pump goes
into HOLD, the fault icon appears on the display, and the
accumulated run time display is frozen and retained. After
5 minutes in flow fault, auto-restart is attempted every
5 minutes until flow is corrected. |
| Battery Pack |
Rechargeable NiCad battery
pack, 2.4V x 0.6 Ah or
Rechargeable NiMH battery
pack, 2.4 V x 1.0 Ah |
| Weight |
5 ounces (142 grams) |
| Dimensions |
4.5 x 2.2 x 1.4 in (11.4
x 5.6 x 3.6 cm) |
| Case |
Impact-resistant stainless steel with ABS/polycarbonate |
| Intrinsically Safe |
UL and cUL Listed |
| RFI/EMI Shielding |
RFI/EMI-shielded case
CE marked
Model 210-1002TX is ATEX approved (NiCad battery model
only).
Contact SKC Ltd
|
Protect sample pump from weather when in use outdoors.
Pocket Pump FAQs
Ordering Information
Pocket Pump - NiMH (Nickel Metal Hydride)
Models
|
| Description |
Voltage |
Cat. No. |
| Pocket Pump only, UL Listed, with NiMH battery (requires
charger; see kits or accessories below.) ATEX-approved models available
(NiCad battery models only); Contact
SKC Ltd. |
|
| Pocket Pump, UL Listed, with NiMH battery and charger,
with U.S. plug |
115V |
|
| Pocket Pump, UL Listed, with NiMH battery and charger,
with U.S. plug |
230V |
|
| Single Pocket Pump Kit includes
Pocket Pump with NiMH battery, single charger, and Type A tube
holder in a soft-side nylon carry case |
115V |
|
230V |
|
| Single Pocket Pump Kit with
Hard-side Pelican Case includes
pump with NiMH battery, single charger, Type A tube holder, and hard-side
Pelican case |
115V |
|
230V |
|
| 5-pack Pocket Pump Kit includes five Pocket
Pumps with NiMH batteries, single chargers, and Type A tube
holders in a convenient carry case |
115V |
|
230V |
|
| 5-pack Pocket Pump Kit with Multi-charger *
includes five Pocket Pumps with NiMH batteries and Type A
tube holders and one 5-station charger in a convenient carry
case |
115V |
|
| Certificate of Compliance, optional, must
be ordered when ordering pumps |
|
| Pocket Pump, ATEX Approved |
|
| Pocket Pump Accessories |
| Description |
Cat. No. |
| Defender Primary Standard Calibrator, 5 to
500 ml/min, includes lead-acid battery, charger, Optimizer 110 software,
and 1-meter serial cable |
|
| DataTrac
Software for
Pocket Pump includes software on CD, adapter, and cable; requires
Windows 98 or higher |
|
| Chargers — Standard |
Voltage |
Cat. No. |
| Multiple Charger, 5-station, for UL Listed pumps,
with U.S. plug |
115 V |
|
| Single Charger, for UL Listed pumps, CSA approved,
with U.S. plug |
115 V |
|
| Single Charger, for UL Listed pumps, with U.S.
plug |
230 V |
|
| Low Flow Constant Pressure Controller (CPC) for
multiple-tube sampling |
|
| Replacement NiMH Battery Pack for UL Listed model |
|
| Replacement NiCAD Battery Pack for UL Listed model |
|
| Replacement Inlet Filter, pk/10 |
|
| Inlet/Pressure Sensor Assembly |
|
| Kit Case: Single Deluxe (Pelican) |
|
| Kit Case: 5-Pack Deluxe (Pelican) |
|
| Kit Case: Single Nylon with Shoulder Strap |
|
| Replacement Valves for Pocket Pump, pk/2 |
|
* |
The Multi-charger is not CSA approved
Pocket Pumps with NiCad battery packs are available from SKC Ltd. The pumps
manufactured by SKC Ltd. will not be UL Listed, but will comply with
the European regulations for intrinsic safety (ATEX). |
† |
Unlike other pumps, Pocket Pump contains circuitry that controls charging,
therefore, the LED on PowerFlex will remain red during the entire charging
process. The Pocket Pump LCD will display charge status. |
Note: |
Replacing batteries with non-approved battery packs voids the pump warranty
and UL intrinsic safety approvals. |
Pocket
Pump Operating Instructions (PDF)
Pocket Pump
Quick Guide (PDF)
Battery Pack
for Pocket Pump Operating Instructions (PDF)
Technical Note:
SKC Sample Pump Battery Pack Characteristics and Maintenance (PDF)
UL
Certificate of Intrinsic Safety (PDF)
EMC
Test Certificate (PDF)
DataTrac
for the Pocket Pump
Instrucciones
de Funcionamento (PDF)
Téléchargement
Guide de I'utilisateur (PDF)
This page was last modified April 9, 2008
|