AirChek 2000 Product Data Bulletin (PDF) AirChek 2000 Operating Instructions (PDF) AirChek 2000 Quick Guide (PDF) Battery Pack for AirChek 2000 Operating Instructions (PDF) Technical Note: SKC Sample Pump Battery Pack Characteristics and Maintenance (PDF) DataTrac 2000 Software Package UL Certificate of Compliance (PDF) KEMA (Keuring van Electrotechnische Materialen) Certificate of Conformity (PDF) Instrucciones de Operación (PDF) Bedienungsanleitung (Kurzfassung)(PDF) Téléchargement
Guide de I'utilisateur (PDF) Schedule it on PC! Battery status display |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Large easy-to-read LCD![]() |
Continuously updated sampling data displays on the AirChek 2000 large LCD. With the press of a single button, scroll through flow rate, air volume, run time, temperature, atmospheric pressure, battery status, time of day, and flow fault. A battery status icon constantly displays and a flow fault icon flashes during restricted or blocked flow. A flashing LED on top of the pump indicates the pump is running in low-light or loud environments. |
| Easy Manual Programming It’s right on the front of the pump. Set flow rate and run time without screwdrivers; simply use the 3-button keypad. A convenient timed shutdown feature allows you to program the AirChek 2000 to run for a set time from 1 to 999 minutes, a very useful feature for STELs or repetitive sample runs. |
![]() Simple 3-button Keypad |
Flow Fault Features:
Long Run Times
AirChek 2000 provides long run times for sampling flexibility. Tests* show the following run times at 2 L/min. All run times are listed in hours.
Mixed Cellulose Ester (MCE) filter, 0.8-µm pore size
Filter Diameter
|
||
Flow Rate (L/min)
|
37 mm
|
25 mm
|
2.0
|
24.2
|
15.2
|
2.5
|
20.4
|
12.4
|
3.0
|
17.7
|
**
|
Filter Diameter
|
||
Flow Rate (L/min)
|
37 mm
|
25 mm
|
2.0
|
28.2
|
21.8
|
2.5
|
27.0
|
22.0
|
3.0
|
22.6
|
18.2
|
| * | Results obtained using a new pump and new fully charged battery. Pump performance may vary. |
| ** | Filter back pressure exceeded pump capability during testing. |
Performance Profile |
|
| Flow Range |
1000 to 3250 ml/min (5 to 500 ml/min requires optional low flow adapter kit) |
| Compensation Range |
3000 ml/min at 15 inches water back pressure 2000 ml/min at 30 inches water back pressure 1000 ml/min at 30 inches water back pressure |
| Flow fault |
If the pump is unable to compensate for longer than 15 seconds due to excessive back pressure, the pump enters flow fault mode. During flow fault, the pump enters Hold, the fault icon appears on the display during the length of the fault, and the accumulated run time display is frozen and retained. After 5 minutes in flow fault, auto-restart is attempted every 5 minutes up to 10 times. |
| Run Time |
With battery pack, run time is 10 hours for 2000 ml/min and up to 30 inches water back pressure; dependent on sample media used. See Table 1 |
Flow accuracy |
± 5% of set-point after calibration to desired flow |
Atmospheric Pressure Accuracy |
± 0.3 in Hg |
Timing Accuracy |
1 min/mo at 25 C |
| Operating Temperature Range |
32 to 113 F (0 to 45 C) |
Charging Temperature Range |
32 to 113 F (0 to 45 C) |
Storage Temperature Range |
-4 to 113 F (-20 to 45 C) |
Altitude Range |
Do not use pump above 7500 ft |
| Battery Pack |
Removable chargeable 4-cell NiCad battery, 4.8 V x 2.0-Ah capacity |
| Size |
5.6 x 3 x 2.3 in (14.2 x 7.6 x 5.8 cm) |
| Weight |
22 oz (624 gm) |
| Intrinsic Safety |
UL and cUL Listed |
| Case |
Impact resistant RFI/EMI shielded CE marked |
Protect sample pump from weather when in use outdoors.
Table 1: Typical Back Pressure of Sampling Media (inches water)
| Flow Rate (L/min) | 1.0 | 1.5 | 2.0 | 2.5 | 3.0 |
| Filter/Pore Size (µm) | |||||
| 25-mm MCE, 0.8 | 6 | 9 | 12 | 15 | 18 |
| 25-mm MCE, 0.45 | 14 | 22 | 28 | 35 | 40 |
| 37-mm MCE, 0.8 | 2 | 3 | 4 | 5 | 6 |
| 37-mm PVC, 5.0 | 1 | 1 | 2 | 2 | 2.5 |
Compare the information in this table to pump compensation range to determine appropriate applications.
Ordering Information
| Description | Voltage |
Cat. No. |
| AirChek 2000 Pump with NiCad battery pack | ||
| AirChek 2000 Pump without Battery | ||
| Single AirChek 2000 Kit (High Flow) includes AirChek 2000 pump, single PowerFlex charger with cable, filter cassette holder, and soft-side nylon carry case | 120 V |
|
100-240 V |
||
| AirChek 2000 High Flow Single Pump Kit with Hard-side Pelican Case includes pump, single charger with cable, filter cassette holder, and hard-side Pelican case | 120 V
|
|
100-240 V
|
||
| Single AirChek 2000 High Flow CalChek Kit includes pump with NiCad battery pack, single PowerFlex charger with cable, filter cassette holder, a CalChek communication cable, Defender Calibrator with charger, and a Pelican carry case | 120V |
|
100-240 V |
||
| 5-pack AirChek 2000 Kit (High Flow) includes 5 AirChek 2000 pumps, filter cassette holders, one 5-station PowerFlex charger with 5 cables, and a Pelican case | ||
| 5-pack AirChek 2000 Kit (High and Low Flow) includes 5-pack high flow items, 5 adjustable low flow holders, 5 constant pressure controllers, and 5 Type A tube covers | 100-240 V |
|
| 5-pack AirChek 2000 High Flow CalChek Kit includes
5 pumps with NiCad batteries, 5-station PowerFlex Charger with 5 cables,
5
filter cassette holders, a CalChek
communication cable, Defender Calibrator with charger, and a Pelican
carry case |
100-240 V |
|
| Certificate of Compliance, optional, must be ordered when ordering pump | ||
| Accessories | ||
| Defender Primary Standard Calibrator
Model 510, 50 to 5000 ml/min, includes lead-acid
battery, multi-plug charger (100-240), Optimizer 110 software, and 1-meter
serial cable Software requires Windows 2000 (SP3) or XP (SP2), or Vista and available COM port on PC. |
||
| CalChek Communication Cable, provides
direct communication between a CalChek-compatible AirChek 2000 or Leland
Legacy pump and a CalChek-capable
Defender primary standard calibrator Note: For use only with Defender calibrators with Revision Level C or higher |
||
| Replacement Defender Lead-acid battery pack | ||
| Defender Universal Charger, 100 to 240 V, with U.S., Euro, and Australia plugs | ||
| Defender Universal Charger, 100 to 240 V, with U.S. plug | ||
| Replacement AirChek 2000 Battery Pack Replacing batteries with non-approved battery packs voids the pump warranty and UL intrinsic safety approvals. |
||
| AC Adapter (Battery Eliminator) 115V, for
continuous pump operation Battery Eliminator should be used in non-hazardous locations only. |
||
| AC Adapter (Battery Eliminator) 230V, for
continuous pump operation Battery Eliminator should be used in non-hazardous locations only. |
||
| Replacement Filter/O-ring, pk/3 | ||
| Replacement Inlet/Filter Housing | ||
| AirChek 2000 Low Flow (5 to 500 ml/min) Adapter Kit includes constant pressure controller (CPC), single adjustable low flow holder, and Type A tube cover | ||
| Chargers — PowerFlex Charging Systems | Cat. No. |
|
| PowerFlex 5-station 100-240 V. Cables must be purchased separately; see below |
223-1000 | |
| PowerFlex Single 120 V. Cables must be purchased separately; see below |
223-2000 | |
| PowerFlex Single 100-240 V. Cables must be purchased separately; see below |
223-2000B | |
|
PowerFlex Cables
|
|
Cat. No. |
| PowerFlex Cable for AirChek 2000 | 1 |
|
| DataTrac
2000 Software Package includes software on CD, adapter, and
serial cable, requires Microsoft Windows 98 or higher, and
available COM port Download DataTrac 2000 now |
||
| Protective Nylon Pump Pouches with belt and adjustable waist and shoulder strap designed for worker comfort when using an AirChek 2000 or 52 pump | Black | |
for easy observation |
||
| Noise-reducing, Black nylon |
||
| Kit Case Single Deluxe Case (Pelican), for SKC pumps. Foam-filled case is watertight, airtight, dustproof, and crushproof; will accommodate a single pump and accessories |
||
| 5-pack Kit Carry Case, for AirChek 2000, AirChek 52, XR5000, or AirLites. On wheels for easy transport, watertight, airtight, dust proof, and crush proof, equipped with foam for complete equipment protection (Pelican) | ||
| Pump Service Training Set for AirChek 2000 Pumps includes a manual and video for distributors and customers who maintain and repair large numbers of AirChek 2000 pumps. The service video on DVD provides basic assembly/disassembly and functional testing. | ||
AirChek 2000 Product Data Bulletin (PDF)
AirChek 2000 Operating Instructions (PDF)
AirChek 2000 Quick Guide (PDF)
Battery Pack for AirChek 2000 Operating Instructions (PDF)
Technical Note: SKC Sample Pump Battery Pack Characteristics and Maintenance (PDF)
DataTrac 2000 Software Package