SKC: Shaping the Future of Air Sampling  

 

 

Special AIHCE pricing!  Click here

AirChek XR5000

Designed for Xtended Range to 5000 ml/min
Xtended Run with Li-Ion Batteries
Xtra Easy Operation
Xtra Back Pressure Compensation
Supercharged Battery Power

210-5000 XR5000 Pump in hand
CE mark
UL Listed logo
Li-ion models

View the XR5000 Video

AirChek XR5000 Operating Instructions (PDF)

AirChek XR5000 Quick Guide (PDF)

AirChek XR5000 Spec. Sheet (PDF)

SKC AirChek XR5000 Air Sampling Pumps CE Conformity Declaration (PDF)

Technical Note: SKC Sample Pump Battery Pack Characteristics and Maintenance (PDF)

Li-Ion Battery Pack for AirChek XR5000 Sample Pumps Operating Instructions (PDF)

MSDS for Lithium-Ion Rechargeable Battery (PDF)

Alkaline Battery Pack for AirChek XR5000 Sample Pumps Operating Instructions (PDF)

Take Charge 5 Li-Ion Battery Charger Operating Instructions (PDF)

AirChek XR 5000 Series UL Certificate (PDF)

Chinese Language AirChek XR5000 Operating Instructions (PDF)

 

  • Extended flow range: 5 to 5000 ml/min (5 to 500 ml/min with Low Flow Adapter Kit)
    • Suitable for low flow gas/vapor or high flow particulate sampling

  • Extended back pressure capabilities
    • Up to 50 inches of water at 2 L/min

  • Enhanced battery power for extended run times*
  • XR5000 Model
    2 L/min
    5 L/min
    High-power Li-Ion
    40 hrs
    22 hrs
    Standard Li-Ion
    20 hrs
    11 hrs
    Alkaline
    18 hrs
    8 hrs
    * Results of run time test, using 37-mm, 0.8-µm MCE filters
    • For extended run times, the pump may be operated while attached to the charger.

  • 3 interchangeable battery options
    • High-power Li-Ion for extended runs
    • Standard Li-Ion for lighter weight
    • Disposable AA alkaline batteries for fast emergency response

  • Patented** highly accurate isothermal flow control system
    • Compensates with ± 5% accuracy

  • UL Listed for intrinsic safety (Li-Ion models only)

  • Automatic flow correction for changes in temperature provides accurate air volumes

  • Extremely simple operation
    • Easy-to-use three-button keypad
    • Continuous run with the push of a button
    • Bright blue pump status LED
    • Easy-to-read LCD displays elapsed time and accumulated run time

  • Set-and-go timer
    • Timed and delayed runs up to 9999 minutes

  • Sample Integrity
    • Lockable keypad
    • Automatic flow fault
    • Auto-restart attempted after 15 seconds in flow fault
    • Flow correction for changes in temperature
    • Accumulated run time display
    • Battery status indicator

  • Standard model weighs only 16 ounces (454 grams)

  • CE marked

  • RoHS compliant

  • Components meet Euro directive for reduction of hazardous substances (including lead) to support green initiatives

** U.S. Patent No. 5,892,160

Performance Profile

Flow Range
1000 to 5000 ml/min (5 to 500 ml/min requires optional low flow adapter kit)
Compensation Range
5000 ml/min at 10 inches water back pressure
4000 ml/min at 20 inches water back pressure
2000 ml/min at 50 inches water back pressure
Typical Back Pressure of Sampling Media (inches water)
Flow Rate (L/min)
1.0
1.5
2.0
2.5
3.0
3.5
4.0
5.0
Filter/Pore Size (µm)                
25-mm MCE/0.8
6
9
12
15
18
21
25
31
25-mm MCE/0.45
14
22
28
35
40
44
50
63
37-mm MCE/0.8
2
3
4
5
6
7
9
11
37-mm PVC/5.0
1
1
2
2
2.5
3
3
4
37-mm polycarbonate/0.45
4
6
8
10
12
15
17
21
25-mm MCE/0.45 microvacuum
21
31
40
48
59
69
79
100
37-mm PTFE/1.0
7.5
11
14.5
19
22
26
30
40
Compare the information in this table to pump compensation range to determine appropriate applications.
Flow Compensation System
Patented isothermal closed loop flow sensor
(U.S. Patent No. 5,892,160)
Accuracies
Timing: 1 min/mo at 25 C
Flow Rate: ± 5% of set-point after calibration to desired flow
Battery Charge Level Indicator
Icon displays on LCD at full, mid, low charge, imminent low battery fault, and low battery fault.
Temperature Range
Operating: 32 to 113 F (0 to 45 C)
Charging: 32 to 113 F (0 to 45 C)
Storage: -4 to 95 F (-20 to 35 C)
Typical Run Times
XR5000 Model
2 L/min
5 L/min
High-power Li-Ion
40 hrs
22 hrs
Standard Li-Ion
20 hrs
11 hrs
Alkaline
18 hrs
8 hrs
Timer Display Range
1 to 9999 minutes (6.8 days). If run time exceeds 6.8 days, timer display rolls over.
Flow Fault
If pump is unable to compensate for > 15 seconds due to excessive back pressure, the pump stops and holds run time display. Auto-restart is attempted every 15 seconds up to 5 times.
Low Battery Fault
15 sec to sleep
Auto-off
5 min of inactivity
Battery Pack
(model dependent)
High-power Li-Ion (4 cell), rechargeable, 7.4 V, 4.4 Ah, 32.6 Wh capacity
or
Standard Li-Ion (2 cell), rechargeable, 7.4 V, 2.2 Ah, 16.3 Wh capacity
or
Alkaline (6 cell), disposable, size AA, 1.5 V (nominal)
Battery Recharge Time
(with SKC-approved charger)
Standard Li-Ion (2 cell): approximately 4 hrs
High-power Li-Ion (4 cell): approximately 8 hrs
Size
High-power Li-Ion and alkaline models: 5.5 x 3 x 2.3 in (14 x 7.6 x 5.8 cm)
Standard Li-Ion model: 4.3 x 3 x 2.3 in (10.9 x 7.6 x 5.8 cm)
Weight
High-power Li-Ion model: 21 oz (0.6 kg)
Standard Li-Ion model: 16 oz (0.45 kg)
Alkaline model: 17 oz (0.48 kg)
Case
Anti-static plastic
RFI/EMI Shielding
CE marked for RFI/EMI protection
Approvals

for use in hazardous locations. Models that are UL Listed for intrinsic safety contain the logo on the label. These models must be used with battery pack Cat. No. P85004 or P85002 to maintain the UL intrinsic safety listing.

RoHS compliant

Ordering Information

AirChek® XR5000 with High-power Li-Ion*

Description
Cat. No.
Pump with battery, requires charger, see kits or charger below
Single Pump Kit includes pump, charger, cassette holder, and soft-side nylon carry case 100-240 V
Single Pump Starter Kit includes pump with battery, charger, Tygon tubing (3 feet, 1/4-inch ID), and collar clip with cable tie 100-240 V
5-pack High Flow Pump Kit includes 5 pumps and cassette holders and 5-station charger, in a Pelican case 100-240 V
5-pack High/Low Flow Pump Kit includes 5 pumps, cassette holders, adjustable low flow holders, constant pressure controllers, and Type A tube covers and 5-station charger, in a Pelican case 100-240 V
Battery Packs
Replacement Battery Pack, SKC Li-Ion high-power 4-cell replacement battery pack for AirChek XR5000 pump, UL Listed for intrinsic safety

P85004

 
Certificate of Compliance, optional, must be ordered when ordering pump
* AirChek XR5000 pumps with Li-Ion batteries may be subject to special shipping regulations.

AirChek XR5000 with Standard Li-Ion*

Description
Cat. No.
Pump with battery, requires charger, see kits or charger below
Single Pump Kit includes pump, charger, cassette holder, and soft-side nylon carry case
100-240 V
Single Pump Starter Kit includes pump with battery, charger, Tygon tubing (3 feet, 1/4-inch ID), and collar clip with cable tie
100-240 V
5-pack High Flow Pump Kit includes 5 pumps and cassette holders and 5-station charger, in a Pelican case
100-240 V
5-pack High/Low Flow Pump Kit includes 5 pumps, cassette holders, adjustable low flow holders, constant pressure controllers, and Type A tube covers and 5-station charger, in a Pelican case
100-240 V
Battery Packs
Replacement Battery Pack, SKC Li-Ion standard 2-cell replacement battery pack for AirChek XR5000 pump, UL Listed for intrinsic safety
Pump Certificate
Certificate of Compliance, optional, must be ordered when ordering pump

AirChek XR5000 with AlkalineNot UL Listed

Description
Cat. No.
Pump with 6 AA-size batteries
5-pack High Flow Pump Kit includes 5 pumps and cassette holders, in a Pelican case
5-pack High/Low Flow Pump Kit includes 5 pumps, cassette holders, adjustable low flow tube holders, constant pressure controllers, and Type A tube covers, in a Pelican case
Battery Packs
Replacement Battery Pack, SKC alkaline 6-cell (size AA) replacement battery pack for AirChek XR5000 pump, non-UL Listed for intrinsic safety
Pump Certificate
Certificate of Compliance, optional, must be ordered when ordering pump
Alkaline model pumps and kits do not include or require a charger.

AirChek XR5000 Without Battery Pack

Description
Cat. No.
SKC Pump only, battery pack not included, charger not included. When attached to an XR5000 high-power Li-Ion battery pack (P85004) or a standard Li-Ion battery pack (P85002), this pump is UL Listed for intrinsic safety. When attached to an alkaline battery pack (P75715), it is non-UL Listed. Low flows from 5 to 500 ml/min require a low flow adapter kit.
Pump Certificate
Certificate of Compliance, optional, must be ordered when ordering pump

 

AirChek XR5000 Accessories

Calibrators and Accessories
Cat. No.
Defender Primary Standard Calibrator, 5 to 500 ml/min, includes lead-acid battery, charger, Optimizer software, and 39-inch (1-meter) serial cable. Software requires Windows XP (SP 2 or 3) or Windows Vista (32 bit version) and an RS-232 port or USB to RS-232 adapter. Defender Primary Standard Calibrator
Defender Primary Standard Calibrator, 50 to 5000 ml/min, includes lead-acid battery, multi-plug charger (100-240 V), Optimizer software, and 39-inch (1-meter) serial cable. Software requires Windows XP (SP 2 or 3) or Windows Vista (32 bit version) and an RS-232 port or USB to RS-232 adapter. Defender Primary Standard Calibrator
Replacement Defender Lead-acid Battery Pack
Defender Universal Charger, 100-240 V, with U.S., Euro, and Australia plugs
Defender Universal Charger, 100-240 V, with U.S. plug
Chargers and Accessories
Single Pump Charger for XR5000 and Leland Legacy includes charging unit and wall cube (100-240 V worldwide power input with interchangeable plugs included) Single Pump Charger 223-241
Take Charge 5 for XR5000 and Leland Legacy, 5-station charger for Li-Ion batteries (100-240 V)

Use in non-explosive locations only; not UL Listed for intrinsic safety
223-441
Single Wall Cube/Power Supply, 100-240 V, with multiple plugs; included as part of the 223-241 Charging Kit Single Wall Cube/Power Supply 223-245
Li-Ion Charging Unit, 100-240V, included as part of the Leland Legacy and AirChek XR5000 Charging Kit, 223-241
Note: Must be used in conjunction with the 223-245 Wall Cube Charger/Power Supply

Li-Ion Charging Unit P22300
Replacement Li-Ion Battery Charging Unit Cable, for charger 223-241 P75632
Protective Pouches
Black, nylon, with belt, adjustable waist, and shoulder strap suitable for high-power Li-Ion and alkaline XR5000 models  
High-profile red, nylon, with belt, adjustable waist, and shoulder strap, suitable for high-power Li-Ion and alkaline XR5000 models
Black, noise-reducing, nylon, with belt, adjustable waist, and shoulder strap, suitable for high-power Li-Ion and alkaline XR5000 models
Black, noise-reducing, nylon, with belt, adjustable waist, and shoulder strap, for standard model  
Kit Case: Single Deluxe Case (Pelican), for SKC pumps. Foam-filled case is watertight, airtight, dustproof, and crushproof; will accommodate a single pump and accessories Kit case: Single Deluxe case (Pelican)
5-Pack Pump Carry Case (Pelican), for AirChek XR5000, AirChek 2000, AirChek 52, and AirLite pumps; on wheels for easy transport, watertight, airtight, dustproof, and crushproof, equipped with foam for complete equipment protection  
Sampling Accessories, Replacement Parts and Tools
Low Flow Adapter Kit (5 to 500 ml/min) includes constant pressure controller, single adjustable low flow holder, and Type A tube cover, suitable for all XR5000 models Low Flow Adapter Kit (5 to 500 ml/min)
Replacement XR5000 Case
Replacement XR5000 Battery Pack Cover
Replacement XR5000 Alkaline Battery Pack Fuse, pk/2
AirChek XR5000 Keypad
AirChek XR5000 Base Plate
Replacement XR5000 PCB (control board)
Replacement XR5000 Top Valve Assembly
Replacement Diaphragm/Yoke Assembly
Replacement Filter/O-ring, pk/3
Replacement Inlet/Filter Housing
Replacement Pump Stack Without Motor
SKC Pneumatic Test Kit, for testing flow compensation in personal sample pumps, 1 to 5 L/min rotameter, 0 to 80 inches magnehelic pressure gauge
SKC Universal Screwdriver Kit, for use with sample pumps, includes 3 interchangeable screwdriver heads 224-11
Mini Tool Kit, for use with air sampling pumps and filter media, includes scissors, pliers, file, 2 slotted screwdrivers, 2 Phillips screwdrivers, forceps, and charcoal pick Mini Tool Kit  376-01-01 376-01-01
*

Li-Ion Battery Shipment
Rechargeable lithium-ion batteries for use with SKC sample pumps have been tested in accordance with the UN Manual and are proven to meet requirements of each test in the UN Manual of Test Criteria, Part III, subsection 38.3. They have a watt-hour (Wh) rating below 100.

Per 2010 IATA regulations, packaging must meet the specifications of and contain labeling and documentation required by IATA Packing Instructions 965, 966, and 967. See IATA Guidance
Document: Transport of Lithium Metal and Lithium Ion Batteries, Revised for the 2010 Regulations

 

AirChek XR5000 Operating Instructions (PDF)

AirChek XR5000 Quick Guide (PDF)

AirChek XR5000 Spec. Sheet (PDF)

SKC AirChek XR5000 Air Sampling Pumps CE Conformity Declaration (PDF)

Technical Note: SKC Sample Pump Battery Pack Characteristics and Maintenance (PDF)

Li-Ion Battery Pack for AirChek XR5000 Sample Pumps Operating Instructions (PDF)

MSDS for Lithium-Ion Rechargeable Battery (PDF)

Alkaline Battery Pack for AirChek XR5000 Sample Pumps Operating Instructions (PDF)

Take Charge 5 Li-Ion Battery Charger Operating Instructions (PDF)

AirChek XR 5000 Series UL Certificate (PDF)

Chinese Language AirChek XR5000 Operating Instructions (PDF)

Spotlight on the SKC AirChek XR5000 Pump PowerPoint Show

HTML Version

Download PowerPoint Show


SKC Air Sampling Pumps

Pump Accessories (Chargers, Calibrators, Flowmeters)


This page was last modified July 21, 2010
  About SKC Terms of Use Privacy Policy Contact Us Ordering Information

This site was last modified July 29, 2010

SKC Inc.'s Quality Policy is in Compliance with IS0 9001-2000
© Copyright 1995-2010 SKC Inc