Grab Air Sample Pump
Simple, Reliable, Economical Bag Sampling
 |
- Uses 9-volt alkaline battery — no down time for
battery charging
- Low-battery indicator
- 1 L/min flow rate
- Approximately 1000 liters volume on one battery
- Minimum setup time — simply attach a bag
and sample
|
Grab
Air Sample Pump Spec. Sheet (PDF)
Grab
Air Sample Pump Operating Instructions (PDF)
The SKC Grab Air Sample Pump is an economical choice for grab-and-go
bag sampling. Grab Air operates at a fixed flow rate of 1 L/min for up
to 1000 liters volume on one 9-volt battery. Simply attach a sample bag
to the outlet port and turn on the pump. Simple, quick, economical — Grab
Air.

Principle of Operation
The Grab Air Sampler pulls air containing the sample into the pump at approximately
1 L/min and immediately exhausts it into a sample bag connected to the pump
with PTFE tubing. Sampling is complete when the bag is properly filled (see
Bag Sampling).
Bag Sampling
Sampling Tips
- Use only PTFE tubing and a PTFE-lined septum for bag sampling
to prevent sample loss.
- Flush bags thoroughly with purified air or nitrogen before use.
- Do not use bags to collect unstable or highly reactive compounds.
- Do not ship sample bags by air unless the cargo cabin is pressurized.
- When sampling for CO or CO2, use SKC
FlexFoil PLUS Grab Bags (252 and 253 Series).
- Avoid filling any bag more than 80% of its maximum volume.
Visually inspect the bag as it is filling to determine when sampling is complete.
Performance Profile
|
| Flow Rate |
Approx. 1 L/min |
| Operation Time |
Approx. 1000 L volume per battery
dependent on battery quality |
| Battery |
Disposable 9-V alkaline |
| Pumping Action |
Diaphragm |
| Case |
Sturdy, lightweight plastic |
| Intrinsic Safety |
Not intended for use in explosive or
hazardous locations |
Protect sample pump from
weather when in use outdoors. |
| Description |
Cat. No. |
Grab Air Sampler with 9-volt battery; for
tubing, see Cat. No. 231-9-23
Use
in non-explosive environments only. Not UL listed for intrinsic
safety. Not CE marked. |
 |
|
Grab Air Hazmat Kit includes
Grab Air pump with 9-volt battery and ten 1-liter
bags
with single polypropylene fitting (Cat. No. 232-01)
Use in non-explosive
environments only. Not UL listed for intrinsic safety. Not CE
marked. |
 |
|
| SKC Universal Screwdriver
Kit, for
use with sample pumps, includes 3 interchangeable screwdriver
heads |
224-11 |
Grab
Air Sample Pump Spec. Sheet (PDF)
Grab
Air Sample Pump Operating Instructions (PDF)
SKC Air Sampling
Pumps
Pump Accessories (Chargers,
Calibrators, Flowmeters)
This page was last modified December 13, 2011
|