Universal Pumps

PCXR4
1000 to 5000 ml/min
(5 to 500 ml/min Low Flow Applications)
Industry Standard Air Sampling Pump
Personal or Area Sampling
Timer and Fault Shutdowns

PCXR4 Universal Personal or Area Air Sampling Pump
CE Mark
UL Listed Logo
EX Logo
ATEX-approved
models available

Ordering Information

PCXR4 Downloads

Performance Profile
224-PCXR4 Air Sampling Pump

Operating Range

1000 to 5000 ml/min (UL Listed model)
(5 to 500 ml/min requires the 224-26 Series adjustable low flow holder)
Requires 1/4-inch ID tubing

Weight
34 oz (964 gm)
Dimensions
5.1 x 4.7 x 1.9 in (13 x 11.9 x 4.8 cm)
Compensation Range
1000 to 2500 ml/min at 40 inches water back pressure
3000 ml/min at 35 inches water back pressure
4000 ml/min at 20 inches water back pressure
5000 ml/min at 10 inches water back pressure
Typical Back Pressure
See Table 1.
Flow Control
Holds constant flow to ± 5% of set-point
Run Time: Battery
NiCad Battery: 8 hrs minimum at 4000 ml/min and 20 inches water back pressure; dependent on media used. See Table 3
NiMH Battery: 12 hrs minimum at 4000 ml/min and 20 inches water back pressure; dependent on media used. See Table 2.
Battery Eliminator: Pump provides extended runs.
Run Time: Mains Adapter
9999 minutes (6.8 days). Pump will shut off as run time cannot exceed timer display. See Timer Display Range below.
Tubing Requires 1/4-inch ID tubing
Timer Display Range
1 to 9999 minutes (6.8 days). Pump will shut off at 9999 minutes. To reset, restart the pump.
Flow Indicator
Built-in rotameter with 250-ml division; scale marked at 1, 2, 3, 4, and 5 L/min
Power Supply
6.0-V plug-in NiMH battery pack, rechargeable, 3.5-Ah capacity or
6.0-V plug-in NiCad battery pack, rechargeable, 2.0-Ah capacity
A battery eliminator is available (see Ordering Information); use voids the UL Listing for intrinsic safety.
Charging Time
(varies with battery capacity and level of discharge)
6 to 8.5 hrs with PowerFlex Charger
Intrinsic Safety

UL Listed for Class I, Division 1 and 2, Groups A, B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III, Temperature Code T3C
ATEX-approved model is available. Contact SKC.

Operating Temperature
32 to 113 F (0 to 45 C)
Storage Temperature
-4 to 113 F (-20 to 45 C)
Charging Temperature
50 to 113 F (10 to 45 C)
Operating Humidity
0 to 95% non-condensing
Flow Fault
If the pump is unable to compensate for longer than 15 seconds due to excessive back pressure, the pump enters flow fault. During flow fault, the pump stops, displays FLOW FAULT, pauses timing functions, and displays elapsed time. Auto-restart is attempted up to 5 times.
Low Battery Fault
Pump stops, displays LO BATT, pauses timing functions, and displays elapsed time.
Battery Test
LCD indicator verifies battery condition prior to sampling
Time Display
LCD displays up to 9999 minutes (6.8 days) at which point the display rolls over to 0.
Timing Accuracy
± 0.05% (± 45 sec/day)
Sampling Pause (Hold)
Allows user to temporarily halt air sampling without loss of timing data. Restart does not require resetting time.
Multiple-tube Sampling
Built-in constant pressure regulator allows user to take up to four simultaneous samples with rates up to 500 ml/min each (total combined flow 1350 ml/min maximum) using the optional adjustable low flow holder accessory
RFI/EMI Shielding
Complies with requirements of EN 55022, FCC Part 15 Class B, EN 50082-1
Frequency range of the radiated susceptibility test was 27 to 1000 MHz
CE marked
Additional Specifications
Built-in fluid/particulate trap
External see-through filter housing
Tamper-resistant control cover
Tamper-resistant compensation adjustments
Built-in accessory mount
Stainless steel belt clip
External exhaust port
All non-plastic parts made of corrosion-resistant materials
RFI and EMI-shielded case
Additional Features
One-year warranty
Ultra-quiet operation
Pulsation-free flow
Impact-resistant case

Protect sample pump from weather when in use outdoors.

Ordering Information

Table 1.
Typical Back Pressure of Sampling Media (inches water)
Compare the information in this back pressure table to pump compensation range to determine appropriate applications.
 Filter/Pore Size (µm) Flow Rate (L/min)
1.0 1.5 2.0 2.5
25-mm MCE/0.8 6 9 12 15
25-mm MCE/0.45 14 22 28 35
37-mm MCE/0.8 2 3 4 5
37-mm PVC/5.0 1 1 2 2

Table 2.
Pump Run Time in Hours with NiMH Battery
Following are typical run times achieved when using a fully charged nickel-metal hydride (NiMH) battery pack. Data is sorted by type of sample media. All run times are listed in hours. Results are obtained using a new fully charged battery. Pump performance may vary.

Mixed Cellulose (MCE) filter, 0.8-µm pore size
Flow Rate (L/min) Filter Diameter     
37 mm 25 mm
2.0 37 33
2.5 34 26
3.0 31 21
3.5 29 18
4.0 25 15
4.5 20 14

Polyvinyl Chloride (PVC) filter, 5.0-µm pore size
Flow Rate (L/min) Filter Diameter     
37 mm 25 mm
2.0 47 41
2.5 38 33
3.0 35 30
3.5 26 27
4.0 22 25
4.5 21 23
NOTE: Increases in back pressure during sampling due to buildup of sample on the filter can decrease battery life.


Table 3.
Pump Run Time in Hours with NiCad Battery
Following are typical run times achieved when using a fully charged nickel cadmium (NiCad) battery pack. Data is sorted by type of sample media.

Mixed Cellulose (MCE) filter, 0.8-µm pore size
Flow Rate (L/min) Filter Diameter     
37 mm 25 mm
2.0 24.1 16.3
2.5 21.4 14.5
3.0 19.1 11.0
3.5 17.8 10.7
4.0 15.4 **
4.5 14.6 **
** 
Filter back pressure exceeded pump capability during testing.

Polyvinyl Chloride (PVC) filter, 5.0-µm pore size
Flow Rate (L/min) Filter Diameter     
37 mm 25 mm
2.0 31.6 21.7
2.5 27.7 24.0
3.0 27.0 18.6
3.5 22.8 16.4
4.0 19.4 16.2
4.5 19.0 14.6
NOTE: Increases in back pressure during sampling due to buildup of sample on the filter can decrease battery life.

 

Personal or Area Sampling
The result of extensive research and development, the PCXR4 is a constant flow air sampling pump suited for a broad range of applications. With an operating range of 1000 to 5000 ml/min (low flow applications of 5 to 500 ml/min require an optional adjustable low flow holder), this battery-operated air sampling pump is ideal for industrial hygiene studies as well as environmental testing. Specifically designed for on-worker and fenceline applications, the PCXR4 air sampling pump is typically used with collecting devices such as:
  • Sorbent sample tubes and long-duration detector tubes for collecting most hazardous chemical gases and vapors from the air
  • Cyclones for collecting respirable dust
  • IOM samplers for collecting inhalable dust
  • Filters for collecting total dust, asbestos, or chemical hazards
  • Tedlar sample bags for collecting airborne chemical hazards
  • Impingers for collecting reactive chemicals into liquids
Powerful Pneumatic System
With its broad flow range, the powerful PCXR4 does the work of both a high flow and low flow pump in a single unit. Its state-of-the-art pneumatic system delivers a constant flow, resulting in accurate air volumes without the need for frequent sampler adjustments. This system includes four components:
  • Pulsation dampener for smooth airflow
  • Built-in flowmeter to monitor pump flow
  • Pressure regulator for low flow sampling
  • Filter assembly to prevent clogging of pump
Long-life NiMH Battery Pack
The NiMH battery pack provides a minimum 12-hour continuous run time. The battery charge test ensures the pump runs the entire shift.


High-accuracy Timer
Using a precision timing circuit, the PCXR4 provides an instant readout of the duration of sampling. A convenient Hold feature allows a pause in sampling; one stroke of the keypad allows the user to resume sampling.

  • Testing possible up to 12 hours
  • Timing accuracy ± 0.05%
  • Large, easy-to-read LCD
Back Pressure Compensation
The PCXR4 is factory-preset to compensate for back pressures to 40 inches water over the most commonly used flow ranges. As back pressure increases, the motor voltage automatically corrects to maintain a constant flow over the operating range. There is no sacrifice to air volume accuracy, even in dusty environments.

Ordering Information

Multiple-tube Sampling Capability
The PCXR4s built-in constant pressure regulator allows users to take up to four simultaneous samples with rates up to 500 ml/min each using an optional adjustable low flow holder (not included). Reduce time in the field and use fewer pumps with multiple-tube air sampling.


Automatic Fault Shutdown
To ensure the integrity of results, the air sampling pump is programmed to shut itself off in the event of:
  • Excessive back pressure
  • Low battery voltage
The pump will automatically enter the Hold mode, and the appropriate indicator (LoBatt or Flow Fault) will light. The LCD will show the elapsed sampling time recorded at the point of shutdown.


A High Standard of Safety
Intrinsically safe, the PCXR4 air sampling pump is UL Listed for explosive gas and dust atmospheres of Class I, Division 1 and 2, Groups A, B, C, D; Class II, Division 1 and 2, Groups E, F, G; and Class III Temperature Code T3C. ATEX-approved model is available. Contact SKC.


RFI and EMI Shielding
PCXR4 case material and unique circuitry are designed to provide shielding from radio frequency in the range of 27 to 1000 MHz. This shielding prevents fluctuations in the flow caused by electrical effects on the pump control circuitry. CE marked

A Variety of Ordering Options
The PCXR4 and its accessories can be purchased together in single and five-pack pump kits or separately for a more customized setup. Accessories include chargers (single or five station), adjustable low flow holders, filter cassette holders, impinger holders, and a protective nylon carrying pouch with shoulder strap and belt. Note: Kits do not contain all the accessories listed here. Contact your SKC regional sales representative for complete ordering information. CE marked

Ordering Information    
Universal XR pumps require 1/4-inch tubing

Description Cat. No.
PCXR4 Air Sampling Pump Only (without charger) includes constant flow air sampling pump with RFI/EMI-shielded case, battery pack, and screwdriver set
Requires charger, see kits or chargers below

ATEX-approved models available, contact SKC
224-PCXR4
PCXR4 Single Pump Kit, High/Low Flow includes sample pump with battery pack, single PowerFlex charger with cable, adjustable low flow holder, Type A tube cover, filter cassette holder, and screwdriver set, in a convenient soft-side nylon carry case
100-240 V
224-PCXR4KD
PCXR4 Single Pump Kit, High/Low Flow, with Hard-side Pelican Case includes pump with battery pack, single PowerFlex charger with cable, adjustable low flow holder, Type A tube cover, filter cassette holder, and screwdriver set, in a hard-side Pelican case
100-240 V
224-PCXR4KDH
PCXR4 Starter Kit includes pump with battery, charger, Tygon tubing (3 feet, 1/4-inch ID), and collar clip with cable tie 100-240 V 224-PCXR4-S

PCXR4 5-pack Pump Kit, High/Low Flow includes 5 sample pumps with battery packs, adjustable low flow holders, Type A tube covers, filter cassette holders, and screwdriver sets and one 5-station charger with cables, in a Pelican carry case

ATEX-approved models are available. Contact SKC.

100-240 V
224-PCXR4K5D
Pump Certificate
Certificate of Compliance, optional, must be ordered when ordering pump P1501
Calibrators
Defender Primary Standard Calibrator, 5 to 500 ml/min, includes lead-acid battery, charger, Optimizer software, and 39-inch (1-meter) serial cable
Software requires Windows XP (sp 2 or 3) or Windows Vista (32-bit version) and an RS-232 port or USB to RS-232 adapter.
Defender Primary Standard Calibrator
Defender Primary Standard Calibrator, 50 to 5000 ml/min, includes lead-acid battery, multi-plug charger (100-240 V), Optimizer software, and 39-inch (1-meter) serial cable
Software requires Windows XP (sp 2 or 3) or Windows Vista (32-bit version) and an RS-232 port or USB to RS-232 adapter.
Defender Primary Standard Calibrator
Defender Universal Charger, 100-240 V, with U.S., Euro, and Australia plugs
Defender Universal Charger, 100-240 V, with U.S. plug
Chargers — PowerFlex Charging Systems
PowerFlex 5-station 100-240 V includes power supply and cord
Purchase pump-specific cables separately; choose from the list below.
For U.S.-produced pump models only, not compatible with EX and ATEX-approved models
223-1000
PowerFlex Single 100-240 V includes power supply and cord
Purchase pump-specific cables separately; choose from the list below.
For U.S.-produced pump models only, not compatible with EX and ATEX-approved models
223-2000
Replacement CE-marked Power Supply for 5-station PowerFlex Charger P22310
PowerFlex Cables
Universal XR Series (5-cell), 1 cable
223-1003 Cable
Replacement Battery Packs

Replacement Battery Pack, NiMH, for XR models
Not suitable for MSHA-approved models

Replacing batteries with non-approved battery packs voids the pump warranty and UL intrinsic safety approvals.

Replacement Battery Pack, NiCad
Not suitable for MSHA-approved models

Replacing batteries with non-approved battery packs voids the pump warranty and UL intrinsic safety approvals.

AC Adapter (Battery Eliminator) 115 V, for extended run times
Use of the Battery Eliminator voids the UL Listing for intrinsic safety.
AC Adapter (Battery Eliminator)
AC Adapter (Battery Eliminator) 230 V, for extended run times
Use of the Battery Eliminator voids the UL Listing for intrinsic safety.
AC Adapter (Battery Eliminator)
Pump Carry Cases
Protective Nylon Pump Pouch with belt and adjustable waist and shoulder strap designed for worker comfort when using Universal XR samplers
High-profile Red, for easy observation
Protective Nylon Pump Pouches High-profile red Cat. No. 224-95A

Protective Nylon Pump Pouch with belt and adjustable waist and shoulder strap designed for worker comfort when using Universal XR samplers
Black

Protective Nylon Pump Pouches High-profile red Cat. No. 224-87
Kit Cases
Single Deluxe Case (Pelican), single pump carry case for SKC pumps. Foam-filled case is watertight, airtight, dustproof, and crushproof; will accommodate a single pump and accessories
Kit Cases Single Deluxe Case (Pelican) Cat. No. 224-901 224-901
5-pack Kit Carry Case (Pelican), Universal XR series, watertight, airtight, dust proof, and crush proof, equipped with foam for complete equipment protection
Replacement Parts and Tools
Replacement Top Valve Plate, for AirChek 52 and Universal Series Pumps
Exhaust Port P22417C
Replacement Tamper-resistant Cover
Replacement External Screws, set
Replacement Cap Screw, set of 2
Replacement Filter Housing, air inlet port and particulate trap
Replacement Filter Kit includes 3 filters and 3 O-rings
Replacement Filters Only, pk/10
Replacement Filter Kit, Economy, includes 100 filters and 10 O-rings
Replacement LCD for Universal Pumps P72392
SKC Pneumatic Test Kit, for testing flow compensation in personal sample pumps, 1 to 5 L/min rotameter, 0 to 80 inches magnehelic pressure gauge 224-6580 SKC Pneumatic Test Kit
SKC Universal Screwdriver Kit, for use with sample pumps, includes 3 interchangeable screwdriver heads
Mini Tool Kit, for use with air sampling pumps and filter media, includes scissors, pliers, file, 2 slotted screwdrivers, 2 Phillips screwdrivers, forceps, and charcoal pick Mini Tool Kit  376-01-01 376-01-01
PCXR4 Downloads

PCXR4 Operating Instructions (PDF)

PCXR4 Spec. Sheet (PDF)

Technical Note: SKC Sample Pump Battery Pack Characteristics and Maintenance (PDF)

Battery Pack for Universal PCXR Sample Pumps Operating Instructions (PDF)

MSDS for Nickel Cadmium Battery GPI International (PDF)

MSDS for Nickel Cadmium Battery SANYO Energy (PDF)

MSDS for Nickel-metal Hydride Battery (PDF)

UL Certificate of Intrinsic Safety

EC Declaration of Conformity (PDF)

Instrucciones de Operación PCXR4 (PDF)

Bedienungsanleitung PCXR4 (PDF)

Mode d’emploi Pompe de prélèvement universelle PCXR4 (PDF)


All SKC Universal Air Sampling Pumps are available with European approvals. Contact the SKC International Sales Department at 724-941-9701 or e-mail at skcorder@skcinc.com for ordering information.


SKC Air Sampling Pumps

Pump Accessories (Chargers, Calibrators, Flowmeters)