Universal Pumps
PCXR8
1000 to 5000 ml/min
(5 to 500 ml/min Low Flow Applications)
Unexcelled Personal or Area Air Sampling Pump
Programmable Start and Stop Times
|
|
|
ATEX-approved
models available
|
Ordering Information
PCXR8
Operating Instructions (PDF)
PCXR8
Spec. Sheet (PDF)
Instrucciones
de Operación
PCXR8 (PDF)
Bedienungsanleitung
PCXR8 (PDF)
Mode
d’emploi Pompe de prélèvement universelle PCXR8
(PDF)
Technical
Note: SKC Sample Pump Battery Pack Characteristics and Maintenance
(PDF)
Battery
Pack for Universal PCXR Sample Pumps Operating Instructions (PDF)
MSDS
for Nickel Cadmium Battery GPI International (PDF)
MSDS
for Nickel Cadmium Battery SANYO Energy (PDF)
MSDS
for Nickel-metal Hydride Battery (PDF)
UL
Certificate of Intrinsic Safety (PDF)
EC
Declaration of Conformity (PDF)
Chinese
Language Operating Instructions PCXR8 (PDF)
Performance Profile
224-PCXR8 Air Sampling Pump
| Flow Range |
1000 to 5000 ml/min (UL Listed model)
(5 to 500 ml/min requires the adjustable low flow holder) |
| Weight |
34 oz (964 gm) |
| Dimensions |
5.1 x 4.7 x 1.9 in (13 x 11.9
x 4.8 cm) |
| Compensation Range |
1000 to 2500 ml/min at 40 inches water back pressure
3000 ml/min at 35 inches water back pressure
4000 ml/min at 20 inches water back pressure
5000 ml/min at 10 inches water back pressure |
Typical Back Pressure |
See Table 1. |
| Flow Control |
Holds constant flow to ± 5%
of set-point |
| Run Time |
NiCad Battery: 8 hrs minimum at
4000 ml/min and 20 inches water back pressure; dependent on media used. See Table 3.
NiMH Battery: 12 hrs minimum at 4000 ml/min
and 20 inches water back pressure; dependent on media used. See
Table 2.
Battery Eliminator: Pump will provide extended runs. |
Timer
Display Range
|
1 to 9999 minutes (6.8 days). Pump will shut off
at 9999 minutes. To reset, restart the pump. |
|
Flow Indicator
|
Built-in rotameter with 250-ml division; scale
marked at 1, 2, 3, 4, and 5 L/min |
Charging Time
(varies with battery capacity and level of discharge) |
6 to 8.5 hrs with PowerFlex charger |
| Power Supply |
6.0-V plug-in NiMH battery
pack, rechargeable, 3.5-Ah capacity or
6.0-V plug-in NiCad battery pack, rechargeable, 2.0-Ah capacity
A battery eliminator is available (see Ordering
Information); use voids the UL Listing for intrinsic safety. |
|
Intrinsic Safety
|
UL Listed for Class I, Division 1 and 2, Groups A, B, C,
D; Class II, Division 1 and 2, Groups E, F, G; and Class
III, Temperature Code T3C
ATEX-approved model is available. Contact
SKC.
|
|
Operating Temperature
|
32 to 113 F (0 to 45 C) |
|
Storage Temperature
|
-4 to 113 F (-20 to 45 C) |
|
Charging Temperature
|
50 to 113 F (10 to 45 C) |
|
Operating Humidity
|
0 to 95% non-condensing |
|
Flow Fault
|
If the pump is unable to compensate for longer than 15 seconds
due to excessive back pressure, the pump enters flow fault.
During flow fault, the pump stops, displays FLOW FAULT, pauses
timing functions, and displays elapsed time or pump time. Auto-restart
is attempted up to 5 times. |
|
Low Battery Fault
|
Pumps stops, displays LO BATT, pauses timing functions,
and displays elapsed time or pump time. |
|
Battery Test
|
LCD indicator shows battery condition prior to sampling |
|
Time Display
|
LCD displays up to 9999 minutes (6.8 days) at which point
the display rolls over to 0. Displays include sampler run time
in minutes for sampling period elapsed time, pump run time,
or total elapsed time including delayed start |
| Delay On |
Allows user to select minutes to delay start
of test up to 9999 minutes (6.8 days) |
| Timed Shutdown |
Allows user to select minutes of
operation before automatic shutdown. Timed shutdown maximum
is 9999 minutes
(6.8 days) |
| Timing Accuracy |
± 0.05% (± 45 sec/day) |
| Intermittent Sampling |
Programmable to allow user to extend
short-term samples over an extended period of time to meet
time-weighted
average (TWA) requirements with a reduced number of samples.
Elapsed time maximum is 9999 minutes (6.8 days), at which
time the sample pump shuts down. |
| Sampling Pause
(Hold) |
Allows user to temporarily halt
sampling without loss of timing data. Restart does not require
resetting time. |
|
Multiple-tube Sampling
|
Built-in constant pressure regulator allows user
to take up to four simultaneous samples with rates up to 500
ml/min each (total combined flow 1350 ml/min maximum) using
the optional adjustable low flow holder accessory |
| RFI/EMI Shielding |
Complies with requirements of EN 55022, FCC Part
15 Class B, EN 50082-1
Frequency range of the radiated susceptibility test was 27 to 1000 MHz
CE marked |
| Additional Specifications |
Built-in particulate trap
External see-through filter housing
Tamper-resistant control cover
Tamper-resistant compensation adjustments
Built-in accessory mount
Stainless steel belt clip
External exhaust port
All non-plastic parts made of corrosion-resistant materials
RFI and EMI-shielded case
|
| Additional Features |
One-year warranty
Ultra-quiet operation
Pulsation-free flow
Impact-resistant case |
Protect sample pump from weather when in use outdoors.
Universal Samplers FAQs
Ordering Information
Table 1.
Typical Back Pressure of Sampling Media (inches water)
Compare the information in this back pressure table to pump compensation range
to determine appropriate applications.
| Filter/Pore Size (µm) |
Flow Rate (L/min) |
| 1.0 |
1.5 |
2.0 |
2.5 |
3.0 |
| 25-mm MCE/0.8 |
6 |
9 |
12 |
15 |
18 |
| 25-mm MCE/0.45 |
14 |
22 |
28 |
35 |
40 |
| 37-mm MCE/0.8 |
2 |
3 |
4 |
5 |
6 |
| 37-mm PVC/5.0 |
1 |
1 |
2 |
2 |
2.5 |
Table 2.
Pump Run Time in Hours with NiMH Battery
Following are typical run times achieved when using a fully charged
nickel-metal hydride (NiMH) battery pack. Data is sorted by type of sample media.
Results are obtained using a new fully charged
battery. Pump performance may vary.
Mixed Cellulose (MCE) filter, 0.8-µm pore size
| Flow Rate (L/min) |
Filter Diameter |
| 37 mm |
25 mm |
| 2.0 |
37 |
33 |
| 2.5 |
34 |
26 |
| 3.0 |
31 |
21 |
| 3.5 |
29 |
18 |
| 4.0 |
25 |
15 |
| 4.5 |
20 |
14 |
Polyvinyl Chloride (PVC) filter, 5.0-µm pore size
| Flow Rate (L/min) |
Filter Diameter |
| 37 mm |
25 mm |
| 2.0 |
47 |
41 |
| 2.5 |
38 |
33 |
| 3.0 |
35 |
30 |
| 3.5 |
26 |
27 |
| 4.0 |
22 |
25 |
| 4.5 |
21 |
23 |
| NOTE: |
Increases in back pressure during sampling due to buildup
of sample on the filter can decrease battery life. |
Table 3.
Pump Run Time in Hours with NiCad Battery
Following are typical run times achieved when using a fully charged
nickel cadmium (NiCad) battery pack. Data is sorted by type of sample media.
All run times are listed in hours.
Mixed Cellulose (MCE) filter, 0.8-µm pore size
| Flow Rate (L/min) |
Filter Diameter |
| 37 mm |
25 mm |
| 2.0 |
24.1 |
16.3 |
| 2.5 |
21.4 |
14.5 |
| 3.0 |
19.1 |
11.0 |
| 3.5 |
17.8 |
10.7 |
| 4.0 |
15.4 |
** |
| 4.5 |
14.6 |
** |
** |
Filter back pressure exceeded pump capability
during testing. |
Polyvinyl Chloride (PVC) filter, 5.0-µm pore size
| Flow Rate (L/min) |
Filter Diameter |
| 37 mm |
25 mm |
| 2.0 |
31.6 |
21.7 |
| 2.5 |
27.7 |
24.0 |
| 3.0 |
27.0 |
18.6 |
| 3.5 |
22.8 |
16.4 |
| 4.0 |
19.4 |
16.2 |
| 4.5 |
19.0 |
14.6 |
| NOTE: |
Increases in back pressure during sampling due to buildup
of sample on the filter can decrease battery life. |
Personal or Area Sampling
The result of extensive research and development, the PCXR8 is a constant flow
air sampling pump suited for a broad range of applications. With an operating
range of 1000 to 5000 ml/min (low flow applications of 5 to 500 ml/min require
an optional adjustable low flow holder), this battery-operated air sampling pump
is ideal for industrial hygiene studies as well as environmental testing. Specifically
designed for on-worker and fenceline applications, the PCXR8
air sampling pump is typically used with collecting devices such as:
- Sorbent sample tubes and
Long-duration detector tubes for collecting most hazardous chemical gases and vapors
from the air
- Cyclones for collecting respirable dust
- IOM samplers for collecting inhalable
dust
- Filters for collecting total dust, asbestos,
or chemical hazards
- Tedlar sample bags for collecting airborne chemical
hazards
- Impingers for collecting reactive chemicals
into liquids
The PCXR8 on-board computer makes operation easy and permits
unattended sampling for periods up to 7 days. In addition, the PCXR8 offers:
- Multiple-tube sampling capability
- Compensation with high back pressure
- Quiet-running package
- Wide range of flow rates
- Energy efficiency
- Programmable timing
The PCXR8 air sampling pump is so dependable, we guarantee its performance for
a period of one year from date of purchase.
Back Pressure Compensation
The PCXR8 is factory-preset to compensate for back pressures
to 40 inches water over the most commonly used flow ranges. As back pressure
increases, the motor voltage automatically corrects to maintain a constant
flow over
the operating range. There is no sacrifice to air volume accuracy, even in dusty
environments.
Multiple-tube Sampling Capability
The PCXR8 built-in constant pressure regulator allows users
to take up to four simultaneous samples with rates up to 500 ml/min each
using an optional adjustable low flow holder (not included). Reduce time
in the field and use fewer pumps with multiple-tube
air sampling.
Powerful Pneumatic System
With its broad flow range, the powerful PCXR8 does the work of both a high flow
and low flow pump in a single unit. Its state-of-the-art pneumatic system delivers
a constant flow, resulting in accurate air volumes without the need for frequent
sampler adjustments. This system includes four
components:
- Pulsation dampener for smooth airflow
- Built-in rotameter to monitor pump flow
- Pressure regulator for low flow air sampling
- Filter assembly to prevent clogging of the pump
Ordering Information
A High Standard of Safety
Intrinsically safe, the PCXR8 air sampling pump is UL Listed for explosive
gas and dust atmospheres of Class I, Division 1 and 2, Groups A, B, C, D; Class
II,
Division 1 and 2, Groups
E,
F,
G;
and
Class III, Temperature Code T3C. ATEX-approved models are available; contact
SKC.
RFI and EMI Shielding
SKC case material and unique circuitry
are designed to provide shielding from radio frequency in the range of
27 to 1000 MHz. This shielding prevents fluctuations in the flow caused by
electrical
effects on the pump control circuitry.
Automatic Fault Shutdown
To ensure the integrity of results, the air sampling pump is programmed to shut
itself off in the event of:
- Excessive back pressure
- Low battery voltage
The pump will automatically enter the Hold mode, and the appropriate indicator
(LoBatt or Flow Fault) will light. The LCD will show the elapsed sampling time
recorded
at the point of shutdown.
Programmable Timing System
Our easy-to-operate, on-board computer gives unsurpassed sampling flexibility
and frees the user to do other jobs. The user can program a delayed start time
for the test (e.g., during the night shift), an automatic shutdown time, or both.
Accuracy
is ± 0.05% (± 45 sec/day).
The current elapsed sampling time reading appears continuously on the large
LCD during a sample run. By pressing the appropriate key, the user can instead
display:
- Total elapsed time (including time delay)
- Pump run time
- Program parameters
Ordering Information
The PCXR8 Air Sampling Pump Has Intermittent Sampling Capability
An Added Bonus at No Extra Cost!
With its computer-controlled timer, the PCXR8 air sampling pump makes intermittent
sampling a reality. Users can now extend the sampling time of chemicals with
analytical methods that dictate low air volumes. By sampling intermittently over
the desired period, air volume requirements are maintained and a true TWA is
achieved. Users
take fewer samples and save analytical costs.
To accomplish this, the user simply enters a sampling time which is greater
than
the pump
run time. The computer then controls the on/off cycling of the pump so that
the sample is taken intermittently over the desired sampling period. TWA tests
ranging from 8 hours to 7 days in duration are possible, depending on the type
of sample being collected.
The 224-PCXR8 offers unique "Short Interval On/Off" air sampling
that gives average concentrations over extended periods: overnight, 24 hours,
weekends, and up to one week—all at the press of a key.
Example: At 4 p.m. on Friday a week long Benzene TWA sample is desired,
extending from noon Sunday until 8 a.m. the following Sunday. Set delayed start
to 44 hours, pump period to 8 hours, and sample period for 6 days, 20 hours.
The computer turns the pump on at noon Sunday with a 1-minute on, 19.5-minute
off
cycle
and shuts
down 6 days and 20 hours later.
Result: A true TWA sample for the entire week.
Computer Controlled PCXR8 Air Sampling Pump
Meets the Challenge
Indoor Air Quality
Challenge: An employee complains about a chemical smell that makes him
sick but the smell never occurs while the investigator is present.
Solution: Program the pump period to 480 minutes (8 hours) and the sample
period for several days. This will allow unattended intermittent sampling and
an opportunity to capture the chemical hazard of interest.
Shiftwork
Challenge: There is a need to monitor employees working the midnight
shift, but health and safety professionals are not available at this time.
Solution: Before leaving the plant at 4 p.m., set the pump for a 480-minute
(8-hour) delay start and a 480-minutes (8-hour) sample period. Leave the pump
and appropriate instructions with the shift supervisor. The pump will
turn on at midnight and shutdown at 8 a.m. All sampling times will be retained
on the LCD.
Fenceline Monitoring
Challenge: The state air control board has requested 24-hour fenceline
monitoring in response to neighborhood concerns.
Solution: Program the pump for a sample period of 1440 minutes (24 hours)
with a pump period of 480 minutes (8 hours). The pump will intermittently sample
a total of 8 hours over the 24-hour period.
(1 minute on, 2 minutes off).
Sample Breakthrough
Challenge: A chemical being sampled has a very short sampling time of
1 hour before breakthrough occurs. Taking several samples is costly and time-consuming.
Solution: Program the pump for a sample period of 480 minutes (8 hours)
with a pump period of 60 minutes (1 hour). The pump will spread the 60 minutes
of run time over the 8 hour workday ensuring a true TWA without the expense of
multiple sample tube analysis.
A Variety of Ordering Options
The PCXR8 and its accessories can be purchased together in
single and five-pack pump kits or separately for a more customized setup. Accessories
include chargers (single or five station), adjustable low flow holders, filter
cassette holders, impinger holders, and a protective nylon carrying pouch with
shoulder strap and belt.
Note: Kits do not contain all the accessories
listed here. Contact
SKC for complete ordering information.
Ordering Information
| Description |
Cat. No. |
PCXR8 Air Sampling Pump Only (without charger) includes
constant flow air sampling pump with RFI/EMI-shielded case, battery
pack, and screwdriver set
Requires charger; see
kits or accessories below
ATEX-approved models available; contact
SKC |
|
| PCXR8 Air Sampling Pump Only (without battery) |
|
| PCXR8 Single Pump Kit, High/Low Flow, includes
sample pump with battery pack,
single PowerFlex charger with cable, adjustable low flow holder, Type A
tube cover, filter cassette holder, and screwdriver set in a convenient
soft-side
nylon carry
case |
100-240 V |
|
| PCXR8 Single Pump Kit, High/Low Flow, with
Hard-side Pelican Case includes pump with battery pack, single
PowerFlex charger with cable, adjustable low flow holder, Type A tube
cover, filter cassette holder, and screwdriver set in a hard-side Pelican
case |
100-240 V |
|
| PCXR8 Starter Kit includes pump with
battery, charger, Tygon tubing (3 feet, 1/4-inch ID), and collar
clip
with cable tie |
100-240 V |
224-PCXR8-S |
PCXR8 5-pack Pump Kit, High/Low
Flow, includes
5 sample pumps with battery packs, adjustable low flow holders, Type A
tube covers, filter cassette
holders, and screwdriver sets
and one 5-station PowerFlex charger with cable, in a Pelican carry
case
ATEX-approved models available; contact
SKC |
100-240 V |
|
| Pump Certificate |
Cat. No.
|
| Certificate of Compliance, optional, must
be ordered when ordering pump |
|
| Calibrators |
Defender Primary Standard Calibrator, 5 to 500 ml/min, includes
lead-acid battery, charger, Optimizer software, and 39-inch (1-meter) serial
cable
Software requires Windows XP (sp 2 or 3) or Windows Vista (32-bit version)
and an RS-232 port or USB to RS-232 adapter |
 |
|
Defender Primary Standard Calibrator, 50 to 5000
ml/min, includes lead-acid battery, multi-plug charger (100-240
V), Optimizer software, and 39-inch (1-meter) serial cable
Software
requires Windows XP (sp 2 or 3) or Windows Vista (32-bit version) and
an RS-232 port or USB to RS-232 adapter. |
 |
|
| Replacement Defender Lead-acid Battery Pack |
|
| Defender Universal Charger, 100-240 V,
with U.S., Euro, and Australia plugs |
|
| Defender Universal Charger, 100-240 V,
with U.S. plug |
|
| Chargers — PowerFlex Charging
Systems |
Cat. No. |
PowerFlex 5-station 100-240 V includes
power supply and cord
Purchase pump-specific cables separately; choose from the
list below.
For U.S.-produced pump models only, not compatible with EX and ATEX-approved
models |
 |
223-1000 |
PowerFlex Single 100-240 V includes power
supply and cord
Purchase pump-specific cables separately; choose from the
list below.
For U.S.-produced pump models only, not compatible with EX and ATEX-approved
models |
 |
223-2000 |
| Replacement CE-marked Power Supply for
5-station PowerFlex Charger |
P22310 |
| PowerFlex Cables
|
Cat. No. |
| Universal XR Series (5-cell), 1 cable |
|
|
| Replacement Battery Packs |
Cat. No. |
|
Replacement Battery Pack, NiMH, for
XR models
Not suitable for MSHA-approved models
Replacing batteries with non-approved battery packs voids the pump
warranty and UL intrinsic safety approvals.
|
|
|
Replacement Battery Pack, NiCad
Not suitable for MSHA-approved models
Replacing batteries with non-approved battery packs voids the pump
warranty and UL intrinsic safety approvals.
|
|
AC Adapter (Battery Eliminator) 115 V, for
continuous pump operation
Use of the Battery Eliminator voids the UL Listing for intrinsic
safety.
|
|
AC Adapter (Battery Eliminator) 230 V, for
continuous pump operation
Use of the Battery Eliminator voids the UL Listing for intrinsic
safety. |
|
| Pump Carry Cases |
Cat. No. |
Protective Nylon Pump Pouch with belt and adjustable
waist and shoulder strap designed for worker comfort when using Universal
XR samplers
High-profile Red, for easy observation |
 |
|
Protective Nylon Pump Pouch with belt and adjustable
waist and shoulder strap designed for worker comfort when using Universal
XR samplers
Black
|
 |
|
Kit Cases
Single Deluxe Case (Pelican), single pump carry case for SKC
pumps. Foam-filled case is watertight, airtight, dustproof, and crushproof;
will accommodate a single pump and accessories |
 |
224-901
|
| 5-pack Kit Carry Case (Pelican), Universal
XR series, watertight, airtight, dust proof, and crush proof, equipped
with foam for complete equipment protection |
|
| Replacement Parts and Tools |
Cat. No. |
Pump Service Training Set for Universal XR Series
Pumps
includes a manual and video for distributors and customers who maintain and
repair large numbers of Universal XR Series Pumps. The service video on DVD
provides basic assembly/disassembly and functional testing. |
|
| Replacement Top Valve Plate, for AirChek
52 and Universal Series Pumps |
|
| Exhaust Port |
P22417C |
| Replacement Tamper-resistant Cover |
|
| Replacement External Screws, set |
|
| Replacement Cap Screw, set
of 2 |
|
| Replacement Filter Housing, air
inlet port and particulate trap |
|
Replacement Filter Kit includes
3 filters and 3 O-rings
|
|
Replacement Filters Only, pk/10
|
|
| Replacement Filter Kit, Economy, includes 100 filters
and 10 O-rings |
|
| Replacement LCD for Universal
Pumps |
P72392 |
| SKC Pneumatic Test Kit, for testing
flow compensation in personal sample pumps, 1 to 5 L/min rotameter, 0 to
80 inches magnehelic pressure gauge |
|
| SKC Universal Screwdriver Kit, for
use with sample pumps, includes 3 interchangeable screwdriver heads |
|
| Mini Tool Kit, for use with air sampling pumps and
filter media, includes scissors, pliers, file, 2 slotted screwdrivers,
2 Phillips screwdrivers, forceps, and charcoal pick |
 |
376-01-01
|
PCXR8
Operating Instructions (PDF)
PCXR8
Spec. Sheet (PDF)
Instrucciones
de Operación PCXR8 (PDF)
Bedienungsanleitung
PCXR8 (PDF)
Mode
d’emploi Pompe de prélèvement universelle PCXR8 (PDF)
Technical Note:
SKC Sample Pump Battery Pack Characteristics and Maintenance (PDF)
Battery
Pack for Universal PCXR Sample Pumps Operating Instructions (PDF)
MSDS
for Nickel Cadmium Battery GPI International (PDF)
MSDS
for Nickel Cadmium Battery SANYO Energy (PDF)
MSDS
for Nickel-metal Hydride Battery (PDF)
UL
Certificate of Intrinsic Safety (PDF)
EC
Declaration of Conformity (PDF)
Chinese
Language Operating Instructions PCXR8 (PDF)
All SKC Universal Air Sampling Pumps are available with European approvals.
Contact
the SKC International Sales Department at 724-941-9701 or e-mail at skcorder@skcinc.com for
ordering information.
This page was last modified March 18, 2010