15 constant flow diaphragm pump maintains a set flow rate throughout
the sampling period, compensating for the inherent back pressure created by sampling
media and for increases in back pressure as sample collects on the media. Unlike
similar pumps, the QuickTake 15:
| Flow range |
5 to 15 L/min |
| Flow compensation accuracy |
± 5% of set flow |
| Compensating flow back pressure range |
15 L/min at 8 inches water back pressure |
| 10 L/min at 15 inches water back pressure |
5 L/min at 20 inches water back pressure
|
Typical Back
Pressure of Sampling Media (inches water)
|
| Flow Rate |
5.0
|
8.0
|
10.0
|
12.0
|
15.0
|
| Filter/Pore Size (µm) |
|
| 37-mm MCE/0.8 |
11
|
18
|
22
|
28
|
36
|
| 37-mm PVC/5.0 |
4
|
7
|
9
|
11
|
15
|
| Compare the information in this table
to compensation range to determine appropriate applications. |
|
| Power |
Rechargeable 7.2-volt lithium-ion (Li-Ion) battery, or
battery with standard AC charger/adapter (115 V), or battery with deluxe
AC charger/adapter (100-240 V)
|
| Battery recharge time |
Approximately 5 hours |
| Typical run time |
VersaTrap cassette: 4 hours at 15 L/min
Results when tested with a new pump and new fully charged battery; pump
performance may vary.
Note: The AC charger/adapter can be used to extend
battery run time, but it is not a battery eliminator. Therefore,
it will not provide indefinite
run times. |
| Run time features |
User-selectable features, user-adjustable presets. See
Operating Instructions. |
| Preset timed runs: 1, 2, 5, 10, or 15 min |
| Manually set continuous run with manual shut-off: 1
to 999 min (repeats 1 to 999-min runs indefinitely until user stops pump
or power supply is depleted) |
| Intermittent sampling: User-set sample
periods and sample delays. See Operating Instructions. |
Flow fault features
|
If the pump is unable to compensate due to excessive back
pressure, the pump will go into flow fault mode. Flow fault features are
enabled as the default setting. Flow fault may be disabled at the user's
option. |
| Flow fault: Flow fault displays immediately.
Pump shuts off after 5 seconds |
| Fault restart: Pump attempts restart every
10 seconds up to five times |
Media compatibility
|
VersaTrap and other bioaerosol cassettes, wall cavity samplers,
BioStage 200 impactor, and other filter cassettes including microvacuum
cassettes |
| Housing |
ABS plastic |
| Dimensions |
10.3 x 4.6 x 2.4 in (26.2 x 11.7 x 6.1 cm) |
| Weight |
32 oz (0.9 kg) |
| Approvals |
CE marked (models with 223-245 charger only) |
The SKC QuickTake 15 Sample Pump is especially easy to use with spore traps (VersaTrap
cassettes)
| Description |
Cat. No. |
QuickTake 15 Sample Pump* and
Charger, 5 to 15 L/min, includes cassette
and tubing adapters (115 V)
Use in non-hazardous locations only. Not UL Listed for intrinsic
safety.
|
228-9515 |
QuickTake 15 Sample Pump*, 5 to 15 L/min, includes battery pack, cassette and tubing adapters, requires
charger, see kits or accessories below
Use in non-hazardous locations only. Not UL Listed for intrinsic
safety. |
228-9515C |
QuickTake 15 Sample Pump* and
Charger, CE marked model with Cat. No. 223-245
charger (100-240 V)
Use in non-hazardous locations only. Not UL Listed for intrinsic
safety. |
228-9515B |
QuickTake 15 Pump* Kit includes
pump, charger, sampling wand, shoulder strap, tripod stand, rotameter,
and carry case (115 V)
Use in non-hazardous locations only. Not UL Listed for intrinsic
safety. |
228-9515K |
QuickTake 15 Pump* Kit with
Cat. No. 320-100 rotameter, includes pump and charger (115 V)
Use in non-hazardous locations only. Not UL Listed for intrinsic
safety. |
228-9515A |
QuickTake 15 Pump* Kit
with CE mark includes
pump, cassette/tubing adapter, sampling wand, shoulder strap, tripod
stand, rotameter, carry case, and worldwide AC charger/adapter (100-240
V) with interchangeable plugs (Cat. No. 223-245)
Suitable for domestic or international use!
Use in non-hazardous locations only. Not UL Listed for intrinsic
safety. |
228-9515KB |
| Certificate of Compliance, optional, must
be ordered when ordering pump |
P1501 |
| Accessories |
| Defender Primary Standard Calibrator, 300 ml/min to
30 L/min, includes lead-acid battery, multi-plug charger (100-240 V), Optimizer
110
Software, and 1-meter serial cable |
717-510H |
| Lithium Ion Replacement Battery Pack* for
QuickTake 15 Series pumps |
|
| Sampling Wand, telescopes to 34 in (0.9 m) for ductwork and hard-to-reach
locations, includes 6 ft (1.8 m) of tubing |
228-9521 |
| Tripod Stand, telescopes to 5 ft (1.5 m) for
mounting sample media or QuickTake 15 |
225-9536 |
| Shoulder Strap, for QuickTake 15 |
228-9520 |
| Rotameter, for QuickTake 15 and 30 |
320-100 |
| Replacement Charger, 115 V |
223-242 |
| Replacement Charger, 100-240 V |
223-245 |
| Replacement Filter/O-ring set includes 5 filters and
1 0-ring |
P40021 |
| Replacement Inlet Filters, pk/50 |
P40021A |
| Replacement Control Board for QuickTake 15 Pump |
P79553 |
| Replacement Case for QuickTake 15 Pump |
P22115 |
| Note: The AC charger/adapter can be used to extend battery
run time, but it is not a battery eliminator. Therefore, it will not provide
indefinite run times. |
| * |
Li-Ion Battery Shipment
Rechargeable lithium-ion batteries for use with
SKC sampling pumps have been tested in accordance with the UN Manual
of Tests and Criteria and are
designated as UN3091.
For air shipments:
Rechargeable lithium-ion batteries in SKC pumps are subject
to the A-45 exemption to the IATA regulations and are not regulated
for air shipments. This information must be written on the shipping
document when shipping by air. For ground shipments:
US DOT regulations specify a limit of 24 or fewer battery
cells in one shipping box. If you exceed 12 QuickTake 15 pumps with
battery packs in one shipping box, specific shipping requirements must
be followed. Contact SKC for more information or refer to the regulatory
authority in your area.
|