About SKC Terms of Use Privacy Policy Careers
© Copyright 2020 SKC Inc. ISO-9001
TrainingMy AccountMy FavoritesCart
×
...
  Home » Catalog » Pumps/Calibrators/Accessories » Air Sampling Pumps to 5 L/min » AirChek Connect (5 to 5000 ml/min)

AirChek Connect
5 to 5000 ml/min


Orderable Items Bluetooth-connected touch screen pump; easily connects to mobile with free app and PC with software. 5 to 5000 ml/min



  • Flows from 5 to 5000 ml/min
    • 5 to 500 ml/min with low flow holder accessory
    • Multiple-tube sampling in low flow mode

  • High back pressure compensation
    • Up to 50 inches water at 2 L/min

  • Bluetooth low-energy connectivity for in-range pump operation/monitoring with:
    • IOS or Android mobile phones and tablets with free SmartWave app – available on the App Store and Google Play
    • PC and DataTrac Pro software

  • Li-Ion battery – over 40-hour run times

  • Corrects flow for changes in temperature and atmospheric pressure

  • Flow fault with auto-restart

  • Large display with continuous parameters

  • Bright running and status LEDs

  • Ultra-quiet

  • Small and lightweight

  • Convenient charging cradle – chain up to 5

  • Screen lock-out and protective cover

 

Performance Profile

Flow Range
• Constant flow from 1000 to 5000 ml/min (5 to 500 ml/min requires low flow holder)
Compensation Range (Back Pressure Capability)
• 5000 ml/min at 20 inches water back pressure
• 4000 ml/min at 30 inches water back pressure
• 3000 ml/min at 40 inches water back pressure
• 2000 ml/min at 50 inches water back pressure
• 1000 ml/min at 60 inches water back pressure
Power
• Removable rechargeable lithium-ion (Li-Ion) battery, 7.4 V, 2.6 Ah, 19.2 Wh or AC using cradle
Run Time
• 40+ hours at 2000 ml/min*
• 15+ hours at 5000 ml/ min*
• Indefinite run from charging cradle
Accuracy
• Flow control: ± 5% of set-point after calibration to desired flow

• Atmospheric pressure: ± 0.3 in Hg

• Temperature: ± 1.0 C
Display/Parameters
• High-contrast backlit LCD/Time, date, battery status, flow rate, sample volume, temperature, atmospheric pressure, back pressure, programmed run remaining time, and elapsed run time
User Interface
• Eight-area capacitive touch screen with auto-dim and locking options
Sound Level
• Average 51.7 dB at 3-ft (1-m) distance using a 37-mm, 0.8-µm MCE filter cassette
Tubing
• Requires ¼-inch ID tubing
Dimensions/Weight
• 4.1 x 3.7 x 2.8 in (10.4 x 9.4 x 7.1 cm),19.4 oz (550 gm)
Certifications



• Intrinsic safety (SKC Cat. No. 220-4000 operated with SKC Battery Pack P75718)

• Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III, T4; Class I, Zone 0

• AExia IIC T4 Ga; Exia IIC T4 Ga; -20°C ≤ Ta ≤ 45°C; Ex II 1G Exia IIC T4 Ga; IECEx UL 19.0100

• DEMKO 19ATEX 2288

• CE 0539

• RoHS compliant

• Designed to meet ISO 13137:2013

* Results obtained using a new pump, new fully charged battery, and 37-mm 0.8-µm MCE filter. Pump and battery performance may vary.
 


 


 


 


 



Listed Intrinsically Safe
Operation
Touch keypad
Touch screen
Touch screen
Programmable
PC Compatible – Download History
Bluetooth
Mobile App
Compensates for Changes in Temperature and Atmospheric Pressure
Flow Fault/Auto-restart