SKC Environmental Air Sampling Guide SKC Guide to OSHA/NIOSH/ASTM Air Sampling Methods SKC Passive Sampling Guide SKC HSE Sampling Guide Need help with hazard assessment for various industries and health concerns? See SKC Sampling Solutions Need help setting up your sampling media for calibration and collection? See SKC Sample Setup Guides Need comprehensive review of air sampling topics? See SKC Presentations: Webinars Presentations Videos
×
...
|
![]() | The personal-size Leland Legacy® air sampling pump offers flows from 5 to 15 L/min, PC-programmability, and up to 24-hour run times for personal or area sampling of low-level contaminants. The pump is ideal for use with impactors, low-volume PUF tubes, filter cassettes, and spore traps. The Leland Legacy air sampling pump is CE marked. It is not UL Listed for intrinsic safety. |
High flows from 5 to 15 L/min
Achieve flow rates that you couldn't reach before when using a personal sample
pump. The Leland Legacy provides the high flows and long run times
of a vacuum-style pump in a compact, portable, and battery-operated sampler within specified back pressure range. NOT for applications requiring instrinsic safety or high back pressures.
Long runs for 24 hours on one battery charge
Rechargeable lithium-ion (Li-Ion) battery pack provides 24-hour run times
with impactors and other sampling devices with low back pressures.* Leland
Legacy is ideal for 24-hour indoor air studies and unattended ambient air
sampling.
* | Leland Legacy is not recommended for high back pressure applications such as asbestos clearance sampling. |
Typical Run Time†
24+ hours:
† | Results obtained using a new pump and new fully charged battery. Pump performance may vary. |
Low Levels
Longer runs at higher flows provide more sample for the enhanced
sensitivity required for measuring low concentrations, particularly
in indoor air environments.
Low Noise
With the noise-reducing case accessory, the Leland Legacy can
operate at 10 L/min and 12 inches water back pressure with
a noise level
of only 52 dBA.**
** Measured
3 feet (1 meter) from pump operating at 10
L/min without media
Advanced flow control
The patented (U.S. Patent Nos. 5,892,160) internal flow sensor measures
flow directly and acts as a secondary standard to constantly maintain
the set flow. Set flow is achieved immediately at start-up
and flow calibration is automatically maintained
by built-in sensors that compensate for differences in temperature
and atmospheric pressure during sampling.
Applications
Use in non-explosive locations only.
Flow Range | 5 to 15 L/min | ||
Closed loop with internal flow sensor | |||
Compensation Range | 15 L/min at 5 inches water back pressure 10 L/min at 12 inches water back pressure 5 L/min at 20 inches water back pressure |
||
Accuracy |
Flow Rate: ± 5% of set-point after calibration
to desired flow Timing: 1 min/mo at 25 C Atmospheric Pressure: ± 0.3 in Hg |
||
Flow Fault | If the pump is unable to compensate for > 15 seconds due to excessive back pressure, a flow fault icon displays and flashes, the pump enters Hold mode, and the pump retains historical data. Auto restart is attempted every 20 seconds up to 10 times. Adjustable with DataTrac for Leland Legacy software | ||
Flow Control | An internal isothermal flow sensor measures flow directly and continuously. Sensor readings are used in a flow monitoring algorithm to maintain calibrated volumetric flow. In addition, built-in atmospheric temperature and pressure sensors provide readings to correct volumetric flow for these parameters when they vary from point of calibration. | ||
Tubing | Requires 3/8-inch ID tubing | ||
Display | LCD, displays pump serial number, pump software revision level, flow rate, volume, temperature, atmospheric pressure, time of day, run time, and pump status, i.e., hold and run as well as Setup information | ||
Volume Display | Continually updated, based on corrected flow rate multiplied by sampling time. When volume exceeds 99,999 liters, the pump will continue to run normally but an O_FLO error will appear on the LCD. | ||
Time Display | Time of day in hours and minutes (12 or 24-hour clock) with AM and PM indicators | ||
Timer Display Range | 1 to 99999 minutes (69 days). If the run time exceeds 69 days, the timer display rolls over. | ||
Operating Temperature Range | 32 to 104 F (0 to 40 C) Protect sample pump from weather when in use outdoors. |
||
Altitude | The pump can apply correction to volumetric flow during sampling for weather-related or altitude variations from the atmospheric pressure established at calibration up to at least 7500 feet (2286 meters) above and 5000 feet (1524 meters) below sea level. | ||
Typical Run Time† |
24+ hours:
|
||
Noise Level | 62.5 dBA — pump without case 52 dBA — pump housed in noise-reducing case (optional accessory Cat. No. 224-89) measured 3 ft (1 m) from pump operating at 10 L/min without media |
||
User-adjustable Values | Sample run time, calibration, clock display, flow rate, time of day, delayed start, and temperature and atmospheric pressure display | ||
Recorded Values | Start date and time, stop date and time, total sample time, flow rate, sample volume, temperature, atmospheric pressure, and pump mode transitions | ||
Adjustable Logging Interval | Records pump history from 3 seconds (15.4 min of data) up to 8 hours (over 102 days of data) depending on setting. Option available when using DataTrac Software | ||
Power Supply | Battery: removable, rechargeable lithium-ion (Li-Ion) battery
pack 7.4 V x 12-Ah capacity, 89 Wh. Charger/AC adapter: input voltage 100-240 V AC |
||
Battery Recharge Time (with SKC-approved charger) | 15 hrs | ||
Temperature: Charging | 32 to 113 F (0 to 45 C) | ||
Temperature: Storage | -4 to 95 F (-20 to 35 C) | ||
Size | 8 x 3.9 x 2.6 in (20 x 10 x 7 cm) | ||
Weight | 36 oz (1 kg) | ||
Case | Thermoplastic with soft rubber overmolding | ||
RFI/EMI Shielding | CE marked |
High flows from 5 to 15 L/min
Achieve flow rates that you couldn't reach before when using a personal sample
pump. The Leland Legacy provides the high flows and long run times
of a vacuum-style pump in a compact, portable, battery-operated sampler within specified back pressure range. NOT for applications requiring instrinsic safety or high back pressures.
Long runs for 24 hours on one battery charge
Rechargeable lithium-ion (Li-Ion) battery pack provides 24-hour run times
with impactors and other sampling devices with low back pressures*. Leland
Legacy is ideal for 24-hour indoor air studies and unattended ambient air
sampling.
* | Leland Legacy is not recommended for high back pressure applications such as asbestos clearance sampling. |
Typical Run Time†
24+ hours:
† | Results obtained using a new pump and new fully charged battery. Pump performance may vary. |
Low Levels
Longer runs at higher flows provide more sample for the enhanced
sensitivity required for measuring low concentrations, particularly
in indoor air environments.
Low Noise
With the noise-reducing case accessory, the Leland Legacy can
operate at 10 L/min and 12 inches water back pressure with
a noise level
of only 52 dBA.**
** Measured
3 feet (1 meter) from pump operating at 10
L/min without media
Advanced flow control
The highly accurate internal flow sensor measures
flow directly and acts as a secondary standard to constantly maintain
the set flow. Set flow is achieved immediately at start-up
and flow calibration is automatically maintained
by built-in sensors that compensate for differences in temperature
and atmospheric pressure during sampling.
Flexible programming
The Leland Legacy Advantage
Collects more sample
High flows and long run times greatly increase the amount of
particulate matter collected when sampling low levels.
This
enhances the usefulness of the data for environmental health and epidemiology
studies.
Designed for indoor
environments
Noise, size, and weight are minimized relative to the high flow
range.
Downloadable history
Critical sampling parameters are retained in
memory during the sampling period and can be downloaded for record keeping.
Click here for the SKC Update to EPA IP-10A (PDF).
* Developed by Dr. Constantinos Sioutas of
the University of Southern California in partnership with NUATRC.
Leland Legacy
and Sioutas Impactor Receive ETV Verification
U.S. EPA Environmental Technology Verification (EPA-ETV)
is a program that furthers environmental protection by accelerating acceptance
and use of improved,
cost-effective technologies through performance verification. EPA-ETV
tested the performance of the SKC Leland Legacy Sample Pump with the Sioutas
Impactor. For a verification report,
visit the AMS Center at http://www.epa.gov/etv/vt-ams.html.
The SKC Leland Legacy and NUATRC
The Leland Legacy was developed in partnership
with the Mickey Leland National Urban Air Toxics Research Center (NUATRC) to
further advance personal exposure
measurement.
Established by Congress in the Clean Air Act Amendments of 1990 (CAAA), the non-profit
Leland Center is responsible for investigating public health risks posed by air
toxics to urban populations. The Leland Center is a private/public research partnership
that brings together corporate, academic, and government scientists to develop
a sound peer-reviewed air toxics research program. This program is jointly supported
by the private sector and the U.S. EPA.
Leland
Legacy Product Data Bulletin (PDF)
Leland Legacy Operating Instructions (PDF)
Leland Legacy Quick Guide (PDF)
Leland Legacy Operating Instructions Chinese (PDF)
Battery Pack for Leland Legacy Sample Pumps Operating Instructions (PDF)
Take Charge 5 Li-Ion Battery Charger Cat. No. 223-441 Operating Instructions (PDF)
SDS Lithium-Ion Rechargeable Battery Leland (PDF)
Technical Note: SKC Sample Pump Lithium-Ion Battery Pack Characteristics and Maintenance (PDF)
Technical Note: SKC Sample Pump Lithium-Ion Battery Packing and Shipping Requirements (PDF)
DataTrac for the Leland Legacy
DataTrac Operating Instructions (PDF)
Leland Legacy EMC Test Certificate (PDF)
Leland Legacy Sample Pump EU Declaration of Conformity (PDF)