SKC Environmental Air Sampling Guide SKC Guide to OSHA/NIOSH/ASTM Air Sampling Methods SKC Passive Sampling Guide SKC HSE Sampling Guide Need help with hazard assessment for various industries and health concerns? See SKC Sampling Solutions Need help setting up your sampling media for calibration and collection? See SKC Sample Setup Guides Need comprehensive review of air sampling topics? See SKC Presentations: Webinars Presentations Videos
×
...
|
![]() | The QuickTake® 30 air sampling pump offers constant flows from 10 to 30 L/min and run times up to 14 hours for sampling particulates. The pump is ideal for use with impactors, microvacuum cassettes, and spore traps. The QuickTake 30 air sampling pump is not UL Listed for intrinsic safety. |
‡ | Pump sampling at 10 L/min using 37-mm 0.8-µm MCE filter with new pumps and batteries. Pump performance may vary. See additional run times in Performance Profile. |
Performance Profile
Flow Range
|
10 to 30 L/min | ||||||||||||||||||||||||||||||||||||||||
Flow Compensation Accuracy
|
± 5% of set flow | ||||||||||||||||||||||||||||||||||||||||
Compensating Flow Back
Pressure Range
|
10 L/min at 90 inches water back pressure 20 L/min at 50 inches water back pressure 30 L/min at 15 inches water back pressure |
||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||
Power
|
Rechargeable lithium-ion (Li-Ion) battery, 7.4-volt, 10.4-Ah capacity, 77 Wh, or battery with AC charger/adapter (100-240 V) | ||||||||||||||||||||||||||||||||||||||||
Battery Recharge Time
(varies with battery capacity and level of discharge) |
Approximately 5 hrs with approved charger | ||||||||||||||||||||||||||||||||||||||||
Typical Cumulative Run
Time‡
|
Spore Trap cassettes (VersaTrap): 5
hrs at 15 L/min (battery only) Note: The AC charger/adapter can be used to extend battery run time, but it is not a battery eliminator. Therefore, it will not provide indefinite run times. |
||||||||||||||||||||||||||||||||||||||||
Temperature
|
Operating: 32 to 104 F (0 to
40 C) Storage: -4 to 95 F (-20 to 35 C) Charging: 32 to 113 F (0 to 45 C) |
||||||||||||||||||||||||||||||||||||||||
Operating Humidity | 0 to 95% non-condensing | ||||||||||||||||||||||||||||||||||||||||
Run Time Features
|
User-selectable features, user-adjustable presets. See
Operating Instructions. Preset timed runs: 1, 2, 5, 10, or 15 min Manually set continuous run with manual shut-off: 1 to 999 min (repeats 1 to 999-min runs indefinitely until user stops pump or power supply is depleted) Intermittent sampling: User-set sample periods and sample delays. See Operating Instructions. |
||||||||||||||||||||||||||||||||||||||||
Flow Fault Features
|
If the pump is unable to compensate due to excessive
back pressure, the pump will go into flow fault mode. Flow fault
features are enabled as the default setting. Flow fault may be
disabled at the user’s option. See Operating Instructions. Flow fault: Flow fault displays immediately. Pump shuts off after 5 seconds. Fault restart: Pump attempts restart every 10 seconds up to five times. |
||||||||||||||||||||||||||||||||||||||||
Media Compatibility
|
BioStage viable cascade impactor, VersaTrap spore trap cassettes, microvacuum cassettes, and other samplers that require flows to 30 L/min | ||||||||||||||||||||||||||||||||||||||||
Tubing
|
Requires 3/8-inch ID tubing | ||||||||||||||||||||||||||||||||||||||||
Housing
|
ABS plastic | ||||||||||||||||||||||||||||||||||||||||
Dimensions
|
8.4 x 9.3 x 3.5 in (21.3 x 23.6 x 8.9 cm) | ||||||||||||||||||||||||||||||||||||||||
Weight
|
4.8 lbs (2.2 kg) | ||||||||||||||||||||||||||||||||||||||||
Noise Level | Average < 64 dBA at 3 feet (37-mm, 0.8-µm MCE filter at 16.8 L/min) |
‡ | Results are obtained using a new pump and new fully charged battery. Pump and battery performance may vary. |
Do not operate or charge in hazardous locations. Not UL
Listed for intrinsic safety.
Protect sample pump from weather when in use outdoors.
The SKC QuickTake 30 constant flow diaphragm pump maintains a set flow rate throughout the sampling period, compensating for the inherent back pressure created by sampling media and for any increase in back pressure as sample collects on the media. Unlike similar pumps, the QuickTake 30:
Ideal for use with the BioStage
QuickTake 30 with BioStage on mounting bracket
* | Li-Ion Battery Shipment |
QuickTake 30 Operating Instructions (PDF)
QuickTake 30 Operating Instructions Chinese (PDF)
QuickTake 30 Operating Instructions Portuguese (PDF)
QuickTake 30 Spec. Sheet (PDF)
QuickTake 30 Secondary Li-ion Battery Pack UL Certificate (PDF)
Technical Note: SKC Sample Pump Lithium-Ion Battery Pack Characteristics and Maintenance (PDF)
Technical Note: SKC Sample Pump Lithium-Ion Battery Packing and Shipping Requirements (PDF)
SDS
for Lithium-Ion Rechargeable Battery (PDF)