Custom Search
...
|
![]() SKC Expert Knowledge--Always Available×
Need help selecting a method and media? See SKC Sampling Guides:
SKC Environmental Air Sampling Guide SKC Guide to OSHA/NIOSH/ASTM Air Sampling Methods SKC Passive Sampling Guide SKC HSE Sampling Guide Need help with hazard assessment for various industries and health concerns? See SKC Sampling Solutions Need help setting up your sampling media for calibration and collection? See SKC Sample Setup Guides Need comprehensive review of air sampling topics? See SKC Presentations: Webinars Presentations Videos
×
...
|
![]() | The EPAM-5000 portable environmental PM monitor provides real-time determinations and data recordings using interchangeable size-selective impactors for PM10, PM2.5, and PM1.0; measures TSP without impactor. The EPAM-5000 is ideal for ambient, environmental, and indoor air quality investigations and baseline surveys. |
* Pump
has a variable flow rate designed for use at 4 L/min to achieve
proper size selection.
Sensing Range | 0.001 to 20 mg/m3 |
0.01 to 200 mg/m3 (optional); specify when ordering | |
0.10 to 2000 mg/m3 (optional); specify when ordering | |
Particle Size Range | 0.1 to 100 µm |
Precision | ± 0.003 mg/m3 (3 µg/m3) |
Accuracy | ± 10% to filter gravimetric SAE fine test dust |
Sampling Flow Rate | 4 L/min |
Filter Cassette Holder (optional accessory) |
47 mm, FRM Style 37 mm or 25 mm (optional) |
Alarm Output | 90 dB at 3 ft |
Analog Output | 0 to 2 vdc |
Recording Time | 1 sec to 15 mos |
Sampling Rate | 1 sec, 10 sec, 1 min, and 30 min |
Data Storage | 21,600 data points |
Security Code | 4-digit combinations |
Memory and Time Storage | > 5 years |
Data Display | Concentration in mg/m3 and TWA, MAX, MIN, STEL, Date, and Time |
Digital Output | RS-232 |
Operating Temperature | 14 to 122 F (-10 to 50) |
Storage Temperature | -4 to 158 F (-20 to 70 C) |
Power | Rechargeable lead-acid and interchangeable battery |
Operating Time | > 24 hrs on battery; continuous on AC |
Charging Time | Approx. 22 hrs |
Dimensions (case) | 14 x 6 x 10 in ( 35.6 x 15.2 x 25.4 cm) |
Weight | 10 lbs (4.5 kg) |
The portable HAZ-DUST EPAM-5000 particulate monitor is ideal for ambient, environmental, and indoor air quality investigations. The highly sensitive EPAM-5000 uses light scattering to measure particle concentration and provide real-time determinations and data recordings of airborne particle concentration in mg/m3. Interchangeable size-selective impactors allow PM10, PM2.5, and PM1.0 monitoring; TSP measuring does not require an impactor. The unique aerodynamic particle sizing and optional 47-mm in-line filter holder loaded with appropriate filter can provide concurrent gravimetric sampling. Download and store sampling data on a PC for analysis and reporting using included DustComm Pro Software.
The EPAM-5000 Advantage
The EPAM-5000 Particulate Air Monitor is available in kits with a 10, 2.5, or 1.0-µm impactor. Each kit contains the EPAM-5000 monitor with a specific cut-point impactor, battery and charger, DustComm Professional Software (Windows, 2000, NT, ME and XP compatible), computer cable, manual, and a portable carry case. Alternate cut-point impactors are available separately. For a lighter weight model with air station capabilities, see the EPAM-7500.
HAZ-DUST is a Trademark of Environmental Devices Corporation.