About SKC Terms of Use Privacy Policy
© Copyright 2019 SKC Inc. ISO-9001
TrainingMy AccountMy FavoritesCart
×
...
  Home » Catalog » Surface Samplers » Chemical Samplers » PERMEA-TEC Pads

PERMEA-TEC Pads


Orderable Items SKC is Now Your Exclusive Source for CLI Surface and Dermal Assessment and Control Tools

On July 15, 2019, SKC Inc. acquired Colormetric Laboratories, Inc. (CLI).
SKC is excited to add CLI products to our highly respected, longstanding sampling solutions that help you maintain the health and safety of workers. SKC looks forward to continuing to provide the same great CLI products with excellent customer and technical support.

PERMEA-TEC Pads Gloves and other personal protective equipment (PPE) can be evaluated for effectiveness in actual field use conditions with PERMEA-TEC Pads. These Pads include both direct-reading colorimetric detectors and a micro-encapsulated solvent indicator system. Chemical penetration through PPE is indicated by the PERMEA-TEC Pads changing color (normal sensitivity range, from 0.5 to 5 mg). Indication of breakthrough can greatly improve PPE selection for specific applications. Send PERMEA-TEC Pads to a laboratory for analysis to identify the chemical (solvent or other compound) penetrating the gloves or garment.



PERMEA-TEC™ Sensors An Important Breakthrough in Glove Selection

Toxic chemicals such as pesticides, aromatic amines, and isocyanates can permeate gloves and protective clothing. Wide variations in the chemical resistance of gloves and protective clothing compositions make protective equipment selection difficult—especially if using mixtures of chemicals in the workplace.

Many factors affect the performance of gloves during actual use. Flexing, stretching, pressure and abrasion are physical factors that can cause premature breakthrough and bring into question reliance on ASTM Laboratory breakthrough data. PERMEA-TEC™ sensors show when breakthrough actually occurs and enables the safety professional to select the glove that is best suited for the job in terms of protection, employee acceptance and cost effectiveness. The sensitivity of the PERMEA-TEC™ sensors is 3-5 µg for aromatic amines and isocyanates.

PERMEA-TEC™ sensors should be attached to the hands of the worker before gloving. It is recommended that the detector be placed on the thumb, middle finger, and palm, as these areas represent the highest degree of contact and abrasion. During initial evaluation of a new glove, the worker should be double gloved as a safety precaution. Attach PERMEA-TEC™ sensors to the outside of the glove currently in use and don the new glove over the first. Check sensors hourly to determine when breakthrough occurs and change gloves accordingly.

The picture above shows a close-up of two PERMEA-TEC™ sensors. The top PERMEA-TEC™ shows the middle strip that has not been exposed to chemical breakthrough. The bottom shows a color change on the middle strip, indicating that break through has occurred.

Studies show that occlusion of skin increases absorption of chemicals by a factor of 5 to 10 times. Gloves and non-porous clothing effectively occlude the skin, thereby resulting in enhanced absorption of permeating chemicals. PERMEA-TEC™ sensors produce a color change when permeation occurs, thus providing a method for field validation of the efficacy of protective clothing. Using PERMEA-TECs™ once a week (on a daily basis when handling highly toxic chemicals) demonstrates the need for safe work practices and documents protection from chemical exposure.

 

PERMEA-TECs™ have been developed for environments that handle:

  • Aromatic Amines
  • Aliphatic Amines
  • Aromatic Isocyanates
  • Aliphatic Isocyanates
  • Acid/Base contaminants
  • Phenols
  • Solvents

Product comes in packages of 20 for breakthrough detection for the chemicals listed above.

 


 


PERMEA-TEC Operating Instructions

PERMEA-TEC Sensor for Aromatic Amines Cat. No. 769-3001

PERMEA-TEC Sensor for Aromatic Isocyanates Cat. No. 769-3002

PERMEA-TEC Sensor for Aliphatic Isocyanates Cat. No. 769-300

PERMEA-TEC Sensor for Aliphatic Amines Cat. No. 769-3005

PERMEA-TEC Sensor for Acid/Base Cat. No. 769-3006

PERMEA-TEC Sensor for Phenols Cat. No. 769-3007

PERMEA-TEC Sensor for Solvents Cat. No. 769-3050

CLI by SKC Products SDS List

Kits

Cat. No.
Description
769-1001  
769-1001 Aromatic Amine Cleaning/Developing Solution
769-1001 Aromatic and Aliphatic Isocyanate Developing Solution
769-1001 DECONtamination Solution for Aromatic Amine
769-1001 D-TAM Skin Cleanser
769-1002  
769-1002 Aromatic and Aliphatic Isocyanate Developing Solution
769-1002 D-TAM Skin Cleanser
769-1002 Isocyanate DECONtamination Solution
769-1003  
769-1003 D-TAM Skin Cleanser
769-1003 Isocyanate DECONtamination Solution
769-1006  
769-1006 Acid/Base Developing Solution
769-1006 Aliphatic Amines Developing Solution
769-1007  
769-1007 D-TAM Skin Cleanser
769-1007 Phenol Developing Solution
769-2002  
769-2002 Aromatic and Aliphatic Isocyanate Developing Solution
769-2003  
769-2003 Aromatic and Aliphatic Isocyanate Developing Solution
Products

Cat. No.
Description
769-1041
769-1041D

Aromatic Amine Cleaning/Developing Solution

769-1051
769-1051D

DECONtamination Solution for Aromatic Amine

769-1052
769-1052D

Isocyanate DECONtamination Solution

769-1061 Aromatic Amine Cleaning/Developing Solution
769-1062 Aromatic and Aliphatic Isocyanate Developing Solution
769-1063 Aromatic and Aliphatic Isocyanate Developing Solution
769-1065 Aliphatic Amines Developing Solution
769-1066 Acid/Base Developing Solution
769-1067 Phenol Developing Solution
769-1071 DECONtamination Solution for Aromatic Amine
769-1072 Isocyanate DECONtamination Solution
769-1073 Isocyanate DECONtamination Solution
769-2001 Aromatic Amine Cleaning/Developing Solution
769-2001 DECONtamination Solution for Aromatic Amine
769-2002 Isocyanate DECONtamination Solution
769-2003

Isocyanate DECONtamination Solution

769-5001 D-TAM Skin Cleanser
769-5011

D-TAM Skin Cleanser