About SKC Terms of Use Privacy Policy
© Copyright 2018 SKC Inc. ISO-9001
TrainingMy AccountMy FavoritesCart
×
...
  Home » Catalog » Pumps/Calibrators/Accessories » Air Sampling Pumps to 30 L/min » QuickTake 30 (10 to 30 L/min

QuickTake 30
10 to 30 L/min


Orderable Items The QuickTake® 30 air sampling pump offers constant flows from 10 to 30 L/min and run times up to 14 hours for sampling particulates. The pump is ideal for use with impactors, microvacuum cassettes, and spore traps.
The QuickTake 30 air sampling pump is not UL Listed for intrinsic safety.



 
  • 10 to 30 L/min constant flow sample pump
    • Maintains set flow throughout a sampling period for complete sample integrity
    • Ideal for use with BioStage viable cascade impactors, spore trap cassettes such as the VersaTrap, microvacuum cassettes, or other samplers that require flows up to 30 L/min within the back pressure range of the pump

  • Long run times on one Li-Ion battery charge
    • AC charger/adapter for extended sampling
    • Rechargeable lithium-ion battery pack

  • Easy-to-use programmable timer for unattended sampling
    • Select sample time presets or customize timer from 1 to 999 minutes
    • Continuous run with manual shut-off
    • Intermittent sampling

  • Compact and portable
    • 9.3 x 8.4 x 3.5 inches (23.6 x 21.3 x 8.9 cm)
    • Weighs only 4.8 pounds (2.2 kg)
    • Portable with easy-grip handle

  • Optional mounting bracket for viable impactor

  • Easy to use
    • Large keypad control
    • End-of-cycle visible and audible alarms
    • Handy front-mounted intake for fast and simple media setup
    • Fast setup

  • High-contrast digital display

  • Low noise
    • Average < 64 dBA at 3 feet (37-mm, 0.8-µm MCE filter at 16.8 L/min)

Pump sampling at 10 L/min using 37-mm 0.8-µm MCE filter with new pumps and batteries. Pump performance may vary. See additional run times in Performance Profile.


 


 


 


 

Performance Profile

Flow Range
10 to 30 L/min
Flow Compensation Accuracy
± 5% of set flow
Compensating Flow Back Pressure Range

10 L/min at 90 inches water back pressure
20 L/min at 50 inches water back pressure
30 L/min at 15 inches water back pressure
Typical Back Pressure of Sampling Media (inches water)
Flow Rate
10.0
12.0
15.0
20.0
Filter/Pore Size (µm)
 
25-mm MCE/0.8
65
80
103
148
25-mm MCE/0.45
138
172
> 200
37-mm MCE/0.8
22
28
36
51
37-mm PVC/5.0
9
11
15
21
Compare the information in this table to compensation range to determine appropriate applications.
Power
Rechargeable lithium-ion (Li-Ion) battery, 7.4-volt, 10.4-Ah capacity, 76.96 Wh, or battery with AC charger/adapter (100-240 V)
Battery Recharge Time
(varies with battery capacity and level of discharge)
Approximately 5 hrs with approved charger
Typical Cumulative Run Time

Spore Trap cassettes (VersaTrap): 5 hrs at 15 L/min (battery only)
BioStage viable cascade impactor: 4 hrs at 28.3 L/min (battery only)
25-mm, 1.2-µm MCE filter: 9+ hrs at 10 L/min
To achieve, use QuickTake 30 with a fully charged battery and AC charger/adapter.
37-mm, 0.8-µm MCE filter: 14+ hrs at 10 L/min (battery only)

Note: The AC charger/adapter can be used to extend battery run time, but it is not a battery eliminator. Therefore, it will not provide indefinite run times.

Temperature
Operating: 32 to 104 F (0 to 40 C)
Storage: -4 to 95 F (-20 to 35 C)
Charging:
32 to 113 F (0 to 45 C)
Operating Humidity 0 to 95% non-condensing
Run Time Features
User-selectable features, user-adjustable presets. See Operating Instructions.
Preset timed runs: 1, 2, 5, 10, or 15 min
Manually set continuous run with manual shut-off: 1 to 999 min (repeats 1 to 999-min runs indefinitely until user stops pump or power supply is depleted)
Intermittent sampling:
User-set sample periods and sample delays. See Operating Instructions.
Flow Fault Features
If the pump is unable to compensate due to excessive back pressure, the pump will go into flow fault mode. Flow fault features are enabled as the default setting. Flow fault may be disabled at the user’s option. See Operating Instructions.
Flow fault: Flow fault displays immediately. Pump shuts off after 5 seconds.
Fault restart: Pump attempts restart every 10 seconds up to five times.
Media Compatibility
BioStage viable cascade impactors, VersaTrap spore trap cassettes, microvacuum cassettes, and other samplers that require flows to 30 L/min
Tubing
Requires 3/8-inch ID tubing
Housing
ABS plastic
Dimensions
8.4 x 9.3 x 3.5 in (21.3 x 23.6 x 8.9 cm)
Weight
4.8 lbs (2.2 kg)
Noise Level Average < 64 dBA at 3 feet (37-mm, 0.8-µm MCE filter at 16.8 L/min)
Results are obtained using a new pump and new fully charged battery. Pump and battery performance may vary.


Do not operate or charge in hazardous locations. Not UL Listed for intrinsic safety.
Protect sample pump from weather when in use outdoors.

 


 


 


 


 


 


 
QuickTake 30 High Flow Pump
Constant Flows for Mold, Bioaerosol, Asbestos, and More


The SKC QuickTake 30 constant flow diaphragm pump maintains a set flow rate throughout the sampling period, compensating for the inherent back pressure created by sampling media and for any increase in back pressure as sample collects on the media. Unlike similar pumps, the QuickTake 30:

  • Maintains true constant flow

  • Does not require a special rotameter or hot-wire anemometer for calibration


Ideal for use with the BioStage
 
BioStage Impactor attached to QuickTake 30 Sample Pump
QuickTake 30 with BioStage on mounting bracket


It's high flow sampling on the go! The portable SKC QuickTake 30 Sample Pump provides fast, easy sampling with the SKC BioStage Viable Cascade Impactor. Use the simple mounting bracket accessory to attach the BioStage directly to the QuickTake 30 pump. There is no need for bulky accessories or line voltage. Sampling with an impactor couldn't be easier!

* 

Li-Ion Battery Shipment
Rechargeable lithium-ion batteries for use with SKC sample pumps have been tested in accordance with the UN Manual and are proven to meet requirements of each test in the UN Manual of Tests and Criteria, Part III, subsection 38.3. The batteries are rated below 100 watt-hours (Wh).

Consult with your carrier for information on Lithium Battery Shipping Regulations for UN 3480 and/or UN 3481 or see SKC Sample Pump Lithium-Ion Battery Packing and Shipping Requirements for more information