AirChek XR5000 Sample Pump, High-power Li-Ion

Please allow your location to be read or register an account with SKC Inc. to view pricing
Part Number: 210-5001

AirChek XR5000 Sample Pump, High-power Li-Ion Overview

AirChek XR5000 (High Power) Pump with battery and screwdriver set; requires charger; see kits or chargers below

Flow range: Constant flow 5 to 5000 ml/min
Low flows from 5 to 500 ml/min require a low flow kit.
UL approved for intrinsic safety

Discover the perfect combination of features and power in this compact, lightweight pump that gets the job done. The AirChek® XR5000 personal air sampling pump with Li-Ion battery provides powerful flows for particulate sampling, low flows for gas and vapor sampling, and the long run-times for low-concentration sampling.
The AirChek XR5000 air sampling pump is UL Listed for intrinsic safety.

 

Performance Profile

Flow Range
1000 to 5000 ml/min  (5 to 500 ml/min requires optional low flow kit)
Compensation Range
5000 ml/min at 10 inches water back pressure
4000 ml/min at 20 inches water back pressure
2000 ml/min at 50 inches water back pressure
Typical Back Pressure of Sampling Media (inches water)
Filter/Pore Size (µm)  
Flow Rate (L/min)
1.
1.5
2
2.5
3
3.5
4
5
25-mm MCE/0.8
6
9
12
15
18
21
25
31
25-mm MCE/0.45
14
22
28
35
40
44
50
63
37-mm MCE/0.8
2
3
4
5
6
7
9
11
37-mm PVC/5.0
1
1
2
2
2.5
3
3
4
37-mm polycarbonate/0.45
4
6
8
10
12
15
17
21
25-mm MCE/0.45 microvacuum
21
31
40
48
59
69
79
100
37-mm PTFE/1.0
1.5
2.5
4
5.5
7
8
9.5
12
Compare the information in this table to pump compensation range to determine appropriate applications.
Flow Compensation System
Isothermal closed loop flow sensor
Tubing
Requires 1/4-inch ID tubing
Accuracies
Timing: 1 min/mo at 25 C
Flow Rate: ± 5% of set-point after calibration to desired flow
Battery Charge Level Indicator
Icon displays on LCD at full, mid, low charge, imminent low battery fault, and low battery fault.
Temperature Range
Operating: 32 to 104 F (0 to 40 C)
Charging: 32 to 113 F (0 to 45 C)
Storage: -4 to 95 F (-20 to 35 C)
Typical Run Times
XR5000 Model
2 L/min
5 L/min
High-power Li-Ion
40 hrs
22 hrs
Standard Li-Ion
20 hrs
11 hrs
Timer Display Range
1 to 9999 minutes (6.8 days). If run time exceeds 6.8 days, timer display rolls over.
Flow Fault
If pump is unable to compensate for > 15 seconds due to excessive back pressure, the pump stops and holds run time display. Auto-restart is attempted every 15 seconds up to 5 times.
Low Battery Fault
15 sec to sleep
Auto-off
5 min of inactivity
Battery Pack
(model dependent)
High-power Li-Ion (4 cell), rechargeable, 7.4 V, 5.2 Ah, 38.5 Wh capacity
or
Standard Li-Ion (2 cell), rechargeable, 7.4 V, 2.6 Ah, 19.2 Wh capacity
Battery Recharge Time
(with SKC-approved charger)
Standard Li-Ion (2 cell): approximately 4 hrs
High-power Li-Ion (4 cell): approximately 8 hrs
Size
High-power Li-Ion model: 5.5 x 3 x 2.3 in (14 x 7.6 x 5.8 cm)
Standard Li-Ion model: 4.3 x 3 x 2.3 in (10.9 x 7.6 x 5.8 cm)
Weight
High-power Li-Ion model: 21 oz (0.6 kg)
Standard Li-Ion model: 16 oz (0.45 kg)
Case
Anti-static plastic
RFI/EMI Shielding
CE marked for RFI/EMI protection
Approvals

for use in hazardous locations. Models that are UL Listed for intrinsic safety contain the logo on the label. These models must be used with battery pack Cat. No. P85004 or P85002 to maintain the UL intrinsic safety listing.

RoHS compliant

  • Pump Flow Rate : 5 to 5000 ml/min
  • PC Compatible : No
  • Programable : Yes
  • Intrinsic Safety : Yes
  • Battery Type (Power) : Li-Ion
  • Approx Run Time : 40

Li-Ion Battery Testing and Shipment
Rechargeable lithium-ion batteries for use with SKC sample pumps have been tested in accordance with the UN Manual and are proven to meet requirements of each test in the UN Manual of Tests and Criteria, Part III, subsection 38.3. The batteries are rated below 100 watt-hours (Wh). Consult with your carrier for information on Lithium Battery Shipping Regulations for UN 3480 and/or UN 3481 or see SKC Sample Pump Lithium-Ion Battery Packing and Shipping Requirements for more information